Purchase and delivery of heart valves for transvascular implantation for the current needs of the University Clinical Hospital in Opole.

Purchase and delivery of heart valves for transvascular implantation for the current needs of the University Clinical Hospital in Opole.

Part 1 — Swine pericardium aortic valve.

Part 2 — Aortic valve of beef pericardium.

Part 1 — Swine pericardium aortic valve.

1 Aortic valves for vascular implantation from porcine pericardium

2 Available sizes: 23 mm, 26 mm, 29 mm, 34 mm

3 Stent mocujący samorozprężalny

4 Valve suitable for implantation with transvascular access

5 Valve protected physico-chemically against calcification and degeneration

6 Complete with each offered valve a set of accessories for implantation through the artery, a delivery system integrated with the shirt and a set of balloons for volvuloplasty enabling valve predilation and post-dilatation, as well as a dedicated rigid guide for valve insertion

7 Possibility of repositioning during implantation

8 Valve visible in X-rays

9 Training of implantation personnel as recommended by the manufacturer

10 Expiry date min. 1 year from delivery date

Aortic valve for transapical or transvascular implantation from bovine pericardium.

1 Aortic valves for vascular implantation of bovine pericardium

2 Available sizes: 20 mm, 23 mm, 26 mm, 29 mm

3 Valve suitable for implantation with transapical, femoral and pre-orthotic access.

4 Mounting stent expanded with a balloon after valve positioning at the implantation site

5 Valve suitable for transapical, femoral and transorthotic access

6 Complete with each offered valve set of accessories for implantation through the heart tip and transvascular route, delivery system, T-shirt

7 Valve visible in X-rays

8 - set of introductor shirts

• 14Fr for 20-26 mm valves and 16Fr for 29 mm valve (transvascular set)

• 18Fr for 20mm valve and 21Fr for 23 - 29 mm valves (transtip set)

• 18Fr for 20-26 mm valves and 21Fr for 29 mm valves (transapical set)

9 Valves in two versions: having a sealing ring, meeting the properties of a system that reduces the risk of leakage around the valve

10 Expiry date min. 1 year from delivery date