Inspection of canals - part 1 - on federal, state and district roads in the district of Waldeck-Frankenberg and Kassel - 2022; lot 1 - 4
B-Street B 251+B 450 i. LK KSLot 1 Federal Highways B 251 and B 450 in LK Kassel
Traffic safety approx. 30 d
Difficulties for accessibility approx. 20 hours
Construction site equipment approx. 1 psch
Sewer cleaning DN 100 - DN 2000 approx. 6,435 m
Wastewater free by shutting off
DN 250 - DN 600 approx. 50 pcs
Construction site equipment approx. 1 psch
Sewer inspection DN 100 - DN 1200 approx. 6,435 m
Documentation Injection data report
per attitude/cond. Report approx. 205 pcs
Documentation Injection data data data data medium approx. 1 pc
Checking for leaks DN 400 to DN 600 approx. 285 m
L Street L 3220 i. LK KSLot 2 State Road L 3220 in LK Kassel
Traffic safety approx. 12 d
Difficulties for accessibility approx. 20 hours
Construction site equipment approx. 1 psch
Sewer cleaning DN 100 - DN 1200 approx. 2,665 m
Wastewater free by shutting off
DN 250 - DN 600 approx. 50 pcs
Construction site equipment approx. 1 psch
Sewer inspection DN 100 - DN 1200 approx. 2,665 m
Documentation Injection data report
per attitude/cond. Report approx. 110 hours
Documentation Injection data data data data medium approx. 1 pc
Checking for leaks DN 400 to DN 600 approx. 60 m
K Str. K 25+K 22 i. LK KSLot 3 Kreisstraße K 25 and K 22 in LK Kassel
Traffic safety approx. 9 d
Difficulties for accessibility approx. 20 hours
Construction site equipment approx. 1 psch
Sewer cleaning DN 100 - DN 1200 approx. 970 m
Wastewater free by shutting off
DN 250 - DN 600 approx. 20 pcs
Construction site equipment approx. 1 psch
Sewer inspection DN 100 - DN 1200 approx. 970 m
Documentation Injection data report
per attitude/cond. Report approx. 38 hours
Documentation Injection data data data data medium approx. 1 pc
Checking for leaks DN 400 to DN 600 approx. 70 m
K street K 37+K 38+K 38 i. LK WFLot 4 District road K 37, K38 and K 40 in the district road Waldeck-Frankenberg
Traffic safety approx. 15 d
Difficulties for accessibility approx. 20 hours
Construction site equipment approx. 1 psch
Sewer cleaning DN 100 - DN 1200 approx. 2,980 m
Wastewater free by shutting off
DN 250 - DN 600 approx. 50 pcs
Construction site equipment approx. 1 psch
Sewer inspection DN 100 - DN 1200 approx. 2,980 m
Documentation Injection data report
per attitude/cond. Report approx. 94 hours
Documentation Injection data data data data medium approx. 1 pc
Checking for leaks DN 400 to DN 600 approx. 4 m