The subject of the order is “Delivery of Endoprostheses and other implants”. A detailed description of the subject of the contract shall include the model of the contract which is annex 3 to the Specification of the terms of the contract (referred to as in the SWZ announcement) and the description of the subject of the disclosure which is Annex 6 to the SWZ. SWZ records should be read along with any changes to SWZ content, which are, for example, the result of answers to Contractors' inquiries. Address of the website where changes and explanations of the contents of the Specification of the terms of the contract and other contract documents directly related to the procurement procedure will be made available: https://www.kcr.pl/rok-2021/ - 'website of the proceed'. The public contract shall be awarded in accordance with the Law of 11 September 2019 — Public Procurement Law (Journal of Laws of 2019, item 2019, as amended), hereinafter referred to as “Pzp” by unrestricted tender, using the so-called “reverse procedure” described in Article 139 Pzp.
Part (package) 1.Part (package) 1.
Task 1. Endoprostheses, /ceramica-polyethylen/ - 50 pieces;
Task 2. Endoprostheses, ceramics-ceramic/- 20 pieces.
A detailed description of the subject of the contract shall include the model of the contract which is Annex 3 to the SWZ and the description of the subject matter of the receipt of Annex 6 to the SWZ SWZ records should be read along with any changes to SWZ content, which are, for example, the result of answers to Contractors' inquiries.
Part (package) 10: A set of implants for the shoulder.Part (package) 10: A set of implants for the shoulder.
Task 1. Button in the shape of a rectangular plate with rounded corners and two incisions for placing two orthopedic bands. Anatomically bent to the surface of the crow and clavicle with laser marker for axial alignment on the bone surface — pieces 10;
Task 2. Surgical tapes made of ultra strong seam material thickness min. 2 not absorbed by min. Widths 2 mm. Designed for augmentation and sewing of the rotator cone, instability of the shoulder and clavicular joints and ankle joints. Tapes completed with a typical surgical neat for use with anchorages, available in 2 colors. Working length of the tape 18 cm +/- 0.5 cm - pieces 20;
Task 3. A hairless implant made of PEEK or PLLA material for repair of the articular ring, rotator cone or biceps tendon tenodesis and repair of small detached tendon and ligament trailers. Introduced/screwed equipped with a special STOP feeder for insertion of tissues to the appropriate depth with control of the force of entry by the operator and preventing loosening of tissues during immersion. The implant should be offered in a minimum of 5 sizes 3.5-9.0 mm together with a special drill and a tool dedicated to a specific, implant size - pieces 30;
Task 4. PEEK version implant or BioComposite for stabilizing the instability of the shoulder joint, a bobless implant with a diameter of 3.0 mm 12.7 mm. Anchor with two two-birth-structure non-absorbable threads, polyethylene internal fibres and braided polyester outer fibers, one of which is used to pierce soft tissues and the other is an auxiliary thread completed by a loop for entering the first thread into the interior anchor, where one thread blocks the other. The kit is a hammered implant with two threads on the feeder, one of which is completed with a loop — a disposable one. Feeder with markers marking the optimal anchorage of the implant. Separation of the feeder from the spontaneous implant after the release of the strand. It can also occur in a nodal version - 10 pieces;
Task 5. Single-use needles for sewing rotator cone tendons or articular ring compatible with the “Scorpion” device — pieces 10;
Task 6. Tenodesis screw, PEEK and BioComposite material, diameter 3mm, 4mm, 4,75mm, 5,5mm, 6,25mm, 7mm, 8mm — pieces 10;
Task 7. Nitinol loop. For stitching tissues, disposable 1.5x300 mm. — pieces 10;
Task 8. Soft arthroscopic canules — elastic, with double collar sealing, easily introducable, for arthroscopic operations of the brachial joint. Availability in 3 sizes - pieces 20;
Task 9. Hard arthroscopic cannulas, with manually relocated in opposite directions, preventing the withdrawal or prolapse of the cannula beyond the joint area, easily introducable, for arthroscopic operations of the brachial joint — pieces 10;
A detailed description of the subject of the contract shall include the model of the contract which is Annex 3 to the SWZ and the description of the subject matter of the receipt of Annex 6 to the SWZ The specifications shall be read along with any changes to the content of the SWZ, which are, for example, the result of responses to Contractors' inquiries.
Part (package) 11: Set for vertebroplasty.Part (package) 11: Set for vertebroplasty.
Task 1. PCD mixer + cement - 35 pcs ;
Task 2. Needle - 100 pcs. ;
Task 3. Biopsy needle - 15 pcs
A detailed description of the subject of the contract shall include the model of the contract which is Annex 3 to the SWZ and the description of the subject matter of the receipt of Annex 6 to the SWZ The specifications shall be read along with any changes to the content of the SWZ, which are, for example, the result of responses to Contractors' inquiries.
Part (package) 12: Spinal implants — lumbar slip reposition.Part (package) 12: Spinal implants — lumbar slip reposition.
Task 1 - Intermolar stabilization with the reposition of the skid in the lumbar region - 10 pcs. ;
Task 2 - Lumbar trunnions PLIF - 5 kpl.
A detailed description of the subject of the contract shall include the model of the contract which is Annex 3 to the SAGE and the description of the subject matter of receipt in Annex 6 to the SWZ. SWZ records should be read along with any changes to SWZ content, which are, for example, the result of answers to Contractors' inquiries.
Part (package) 13: Stabilization of the lumbar spine PLIF and TLIF.Part (package) 13: Stabilization of the lumbar spine PLIF and TLIF.
Task 1 - lumbar titanium intermolar cage, PLIF type 3D - 20 sets;
Task 2 - Lumbar titanium intermolar cage, TLIF type 3D - 20 sets;
A detailed description of the subject of the contract shall include the model of the contract which is Annex 3 to the SAGE and the description of the subject matter of receipt in Annex 6 to the SWZ. SWZ records should be read along with any changes to SWZ content, which are, for example, the result of answers to Contractors' inquiries.
Part (package) 14: Stabilization of the cross-hip joint - 4 sets.Part (package) 14: Stabilization of the cross-hip joint - 4 sets.
A detailed description of the subject of the contract shall include the model of the contract which is Annex 3 to the SAGE and the description of the subject matter of receipt in Annex 6 to the SWZ. SWZ records should be read along with any changes to SWZ content, which are, for example, the result of answers to Contractors' inquiries.
Part (package) 2: Endoprosthetics of the knee.Part (package) 2: Endoprosthetics of the knee.
Task 1. Endoprosthesis of the knee joint cemented — 200 pieces, including 60 MB and 140 pieces of FB;
Task 2. Endoprosthesis of the knee joint cemented with an option for younger patients — 50 pieces;
Task 3. Endoprosthesis of the knee joint with polyethylene tibia element - 150 pieces;
Task 4. Endoprosthesis revision of the knee with complementary cuffs, compatible with the primary endoprosthesis system - 25 pieces;
Task 5. Revision endoprosthesis of the knee with complementary cuffs bound - 10 pieces;
Task 6. Modular prostheses allowing resection of the entire femur - 2 pieces.
A detailed description of the subject of the contract shall include the model of the contract which is Annex 3 to the SWZ and the description of the subject matter of the receipt of Annex 6 to the SWZ SWZ records should be read along with any changes to SWZ content, which are, for example, the result of answers to Contractors' inquiries.
Part (package) 3: Endoprostheses temporal /Walk.Part (package) 3: Endoprostheses temporal /Walk.
Task 1. Temporal endoprosthesis of the hip joint - 15 pieces;
Task 2. Temporal endoprosthesis of the knee joint - 15 pieces.
A detailed description of the subject of the contract shall include the model of the contract which is Annex 3 to the SWZ and the description of the subject matter of the receipt of Annex 6 to the SWZ SWZ records should be read along with any changes to SWZ content, which are, for example, the result of answers to Contractors' inquiries.
Part (bundle) 4: Endoprosthetics of the knee joint - 50 pieces.Part (bundle) 4: Endoprosthetics of the knee joint - 50 pieces.
A detailed description of the subject of the contract shall include the model of the contract which is Annex 3 to the SWZ and the description of the subject matter of the receipt of Annex 6 to the SWZ SWZ records should be read along with any changes to SWZ content, which are, for example, the result of answers to Contractors' inquiries.
Part (package) 5: Complementary elements.Part (package) 5: Complementary elements.
Task 1 System of standard cone reducers for hip revision operations — 20 sets;
Task 2 System of custom cone reducers for hip revision operations 1 set.
A detailed description of the subject of the contract shall include the model of the contract which is Annex 3 to the SWZ and the description of the subject matter of the receipt of Annex 6 to the SWZ SWZ records should be read along with any changes to SWZ content, which are, for example, the result of answers to Contractors' inquiries.
Part (package) 6: Bone Cements.Part (package) 6: Bone Cements.
Task 1. Medium viscosity bone cement with copolymer methylacrylate MA with the addition of gentamicin. The content of the active substance should not exceed 1.5% of the powdered substance. Packaging 40 g - 250 pieces;
Task 2. Medium viscosity bone cement with copolymer methylacrylate MA with the addition of gentamicin. The content of the active substance should not exceed 1.5% of the powdered substance. Packaging 2x40 g - 100 pieces;
Task 3. Revision bone cement with two active antibiotics. High viscosity bone cement with the addition of gentimycin and clindamycin. Packaging 40 g. - 100 pieces;
Task 4. Revision bone cement with two active antibiotics.High viscosity bone cement with the addition of gentimycin and vancomycin. Packaging 40 g. - 25 pieces;
Task 5. Multiphase flushing system based on the power of the flushing stream, for soft tissues and bone, respectively, containing a universal kit for the knee and hip, and sucking trauma surgery equipped with 2 disposable tips: long ducted and short with rinse cover surface/ condyles of the knee, acetabulum, open operating wound/- 50 pieces;
Task 6. Vacuum mixer for cement. Double set (so-called hip) — containing 2 mixers/syringes equipped with an air filter and a nozzle of 2 lengths (long and short). Volume 2 x 80 g. - 100 pieces;
Task 7. Vacuum mixer for cement. Single set (so-called knee) — containing 1 mixer/syringe equipped with an air filter and a nozzle of 2 lengths (long and short). Volume 1x80 g. - 50 pieces.
A detailed description of the subject of the contract shall include the model of the contract which is Annex 3 to the SWZ and the description of the subject matter of the receipt of Annex 6 to the SWZ SWZ records should be read along with any changes to SWZ content, which are, for example, the result of answers to Contractors' inquiries.
Part (package) 7: Endoprosthesis of the brachiocephalic joint - 8 pcs.Part (package) 7: Endoprosthesis of the brachiocephalic joint - 8 pcs.
A detailed description of the subject of the contract shall include the model of the contract which is Annex 3 to the SWZ and the description of the subject matter of the receipt of Annex 6 to the SWZ The specifications shall be read along with any changes to the content of the SWZ, which are, for example, the result of responses to Contractors' inquiries.
Part (package) 8: WKP/WKT Reconstruction Implants Set.Part (package) 8: WKP/WKT Reconstruction Implants Set.
Task 1. System for the reconstruction of the anterior or posterior ligament based on the fixation of the corpus with the help of a longitudinal plate. Tile with 2 holes made of titanium alloy, rectangular shape with rounded sides of 12mm length, continuously connected to a loop of unabsorbed thread length of 50mm, allowing for suspension of graft in the femoral or tibial duct and from thread to drag the implant onto the outer cork. Loop to pull up graft with the ability to reduce loop length with reins — graft fixation in the channel. Possibility of pulling up the graft in the line of the pulled graft - pieces 50;
Task 2. Titanium screws — System for reconstruction of anterior ACL ligament and rear PCL based on titanium screws. Implant built of titanium. A screw with a unique shape for easy introduction, available in a version with a soft thread along the entire length. Implants in sizes from 6-10 mm in diameter 20-35 mm. Available version with a disposable cannula to facilitate the introduction of the implant. Implant in sterile version packaged individually - pieces of 40;
Task 3. Biocomposite screws — System for reconstruction of anterior ACL ligament and rear PCL based on Biocomposite screws. Implant built in 30% from calcium diphosphate and 70% from PLDLA. Screw with a unique shape for easy insertion with a soft thread along the entire length. The process of combining two materials strengthens implant parameters and micro pores and holes along the axis of the implant facilitates remodeling and overgrowth of the bone. Implants in diameter 6-10mm and length 20mm, diameter 7-12mm and length 30mm. For easier and more precise insertion, the socket screws six-pointed conical. The sterile implant packaged individually - pieces 10;
Task 4. Drilling wire with a closed eye and a scoop every 5 mm, completed with a sharp grotto and a drill under the thigh plate. Sterile — pieces — 10;
Task 5. Tibial wire 2.4 mm x 311 mm. Packed sterile - pieces 10;
Task 6. Nitinol wire for 1.1mm diameter interference screw. Designated markings on wire in lengths of 25mm and 30mm. Packed sterile - pcs 5;
Task 7. Specialized reinforced surgical seam #2 -0, lengths in the range 40-50 cm and 90-100 cm - pieces 20.
A detailed description of the subject of the contract shall include the model of the contract which is Annex 3 to the SWZ and the description of the subject matter of the receipt of Annex 6 to the SWZ SWZ records should be read along with any changes to SWZ content, which are, for example, the result of answers to Contractors' inquiries.
Part (package) 9: Meniscus sewing kit - 20 pcsPart (package) 9: Meniscus sewing kit - 20 pcs
A detailed description of the subject of the contract shall include the model of the contract which is Annex 3 to the SWZ and the description of the subject matter of the receipt of Annex 6 to the SWZ The specifications shall be read along with any changes to the content of the SWZ, which are, for example, the result of responses to Contractors' inquiries.