Miscellaneous medical devices and products | Tenderlake

Miscellaneous medical devices and products

Contract Value:
EUR 129M - 129M
Notice Type:
Contract Notice
Published Date:
09 October 2023
Closing Date:
20 November 2023
Location(s):
ITH57 Ravenna (IT Italy/ITALIA)
Description:
DM for Gastroenterology and Digestive Endoscopy 2

TELEMATIC OPEN PROCEDURE TENDER FOR THE SUPPLY OF MEDICAL DEVICES AND PROSTHETIC MATERIAL FOR GASTROENTEROLOGY AND DIGESTIVE ENDOSCOPY SERVICES – EDITION 2 FOR THE NEEDS OF THE AUSL OF ROMAGNA

DISPOSABLE STERILE BILIARY PROSTHESES IN PLASTIC MATERIAL

DISPOSABLE STERILE BILIARY PROSTHESES IN PLASTIC MATERIAL

OTW self-expanding stent in nitinol (or other metal shape memory material) completely covered in silicone for the acute treatment of bleeding from esophageal varices equipped with an intravascular balloon for anchoring.

OTW self-expanding stent in nitinol (or other metal shape memory material) completely covered in silicone for the acute treatment of bleeding from esophageal varices equipped with an intravascular balloon for anchoring.

Dissection needle type Triangle Tip Knife

Dissection needle type Triangle Tip Knife

Dissection needle type IT Knife,

Dissection needle type IT Knife,

Flush Knife dissecting needle

Flush Knife dissecting needle

Dissection and injection needle, with disc type tip

Dissection and injection needle, with disc type tip

Dual Knife type dissecting needle

Dual Knife type dissecting needle

Dissection and injection needle, with different tip morphologies, compatible with "ERBEJET 2" hydrodissection system + cartridge

Dissection and injection needle, with different tip morphologies, compatible with "ERBEJET 2" hydrodissection system + cartridge

Injection and dissection needle with gold tip

Injection and dissection needle with gold tip

Distal caps, straight, variable lengths and diameters

Distal caps, straight, variable lengths and diameters

Distal caps, obliques, variable lengths and diameters

Distal caps, obliques, variable lengths and diameters

Distal caps, in soft, cylindrical plastic material, equipped with anti-fog hole

Distal caps, in soft, cylindrical plastic material, equipped with anti-fog hole

Oval lug, wide range of openings from 10 to 25 mm. approx., braided cable length 2300 mm.

Oval lug, wide range of openings from 10 to 25 mm. approx., braided cable length 2300 mm.

Monopolar diathermic forceps for polypectomy

Monopolar diathermic forceps for polypectomy

Coagrasper clamp

Coagrasper clamp

Flexible bipolar hemostasis forceps, equipped with smooth and flat valves

Flexible bipolar hemostasis forceps, equipped with smooth and flat valves

Submucosal injection lifting agent for endoscopic resection procedures.

Submucosal injection lifting agent for endoscopic resection procedures.

Endoscopic endoluminal polyurethane system for the treatment of post-surgical anastomotic dehiscences

Endoscopic endoluminal polyurethane system for the treatment of post-surgical anastomotic dehiscences

Kit for full-thickness resection of lesions of the digestive tract

Kit for full-thickness resection of lesions of the digestive tract

System for endoscopic mucosal resection of the upper digestive tract including ligator and loop.

System for endoscopic mucosal resection of the upper digestive tract including ligator and loop.

Kit for performing full-thickness endoscopic sutures, using non-absorbable suture threads

Kit for performing full-thickness endoscopic sutures, using non-absorbable suture threads

Sterile disposable sheet in twin-coupled TNT for endoscopic procedures

Sterile disposable sheet in twin-coupled TNT for endoscopic procedures

Cover cover compatible with endoscope trays in use

Cover cover compatible with endoscope trays in use

Oval lug, opening from 10 to 30 mm. About monofilament cable length 2300 mm. approximately

Oval lug, opening from 10 to 30 mm. About monofilament cable length 2300 mm. approximately

STERILE DISPOSABLE MATERIAL FOR ERCP QUICK EXCHANGE

STERILE DISPOSABLE MATERIAL FOR ERCP QUICK EXCHANGE

TWO-WAY PAPILLOTOME

TWO-WAY PAPILLOTOME

"SMALL" PAPILLOTOME FOR PAPILLA MINOR with double lumen.

"SMALL" PAPILLOTOME FOR PAPILLA MINOR with double lumen.

STANDARD THREE-WAY PAPILLOTOME

STANDARD THREE-WAY PAPILLOTOME

PAPILLOTOME WITH TIP ROTATION MECHANISM

PAPILLOTOME WITH TIP ROTATION MECHANISM

PAPILLOTOME FOR DIFFICULT STONES

PAPILLOTOME FOR DIFFICULT STONES

PAPILLOTOME WITH COATING

PAPILLOTOME WITH COATING

PAPILLOTOMO "PRE CUT"

PAPILLOTOMO "PRE CUT"

Teflon catheter with radiopaque end

Teflon catheter with radiopaque end

Radiologically viewable ERCP catheter with double lumen

Radiologically viewable ERCP catheter with double lumen

Asymmetrical loop duck beak type configuration, opening in the range from 10 to 25 mm. approx., braided cable length 2300 mm. approximately

Asymmetrical loop duck beak type configuration, opening in the range from 10 to 25 mm. approx., braided cable length 2300 mm. approximately

Disposable locking system of the guide wire on the working channel of the duodenoscope

Disposable locking system of the guide wire on the working channel of the duodenoscope

Sterile disposable basket in nitinol or similar material

Sterile disposable basket in nitinol or similar material

Sterile disposable basket in nitinol or similar material, WIRE-GUIDED

Sterile disposable basket in nitinol or similar material, WIRE-GUIDED

WIRE-GUIDED STERILE DISPOSABLE BASKET WITH INTEGRATED LITHOTRIPSY FUNCTION

WIRE-GUIDED STERILE DISPOSABLE BASKET WITH INTEGRATED LITHOTRIPSY FUNCTION

ENDOCANAL MECHANICAL LITHOTRIPTER FOR ENDOSCOPIC LITHOTRIPSY

ENDOCANAL MECHANICAL LITHOTRIPTER FOR ENDOSCOPIC LITHOTRIPSY

HANDLE + EXOCANALAR MECHANICAL LITHOTRIPTER JACKET TYPE "SOHENDRA"

HANDLE + EXOCANALAR MECHANICAL LITHOTRIPTER JACKET TYPE "SOHENDRA"

Balloon catheters for three-way gallstone extraction

Balloon catheters for three-way gallstone extraction

PANCREATIC PROSTHESES

PANCREATIC PROSTHESES

Radiopaque polyethylene biliary nail drainage set

Radiopaque polyethylene biliary nail drainage set

Radiopaque catheter for difficult cannulation of the papilla in ERCP

Radiopaque catheter for difficult cannulation of the papilla in ERCP

Polypectomy loop with integrated needle

Polypectomy loop with integrated needle

PAPILLOTOMO PER GASTRORESECATO BII

PAPILLOTOMO PER GASTRORESECATO BII

Adattatore per ERCP ad Y

Adattatore per ERCP ad Y

Rail coated with hydrophilic polymer

Rail coated with hydrophilic polymer

Radiopaque guide wire coated with hydrophilic polymer

Radiopaque guide wire coated with hydrophilic polymer

Super Stiff guide wire with NITINOL core, super-rigid, for the placement of prostheses in difficult conditions

Super Stiff guide wire with NITINOL core, super-rigid, for the placement of prostheses in difficult conditions

Guide wire with diameter 0.035 and length 450 cm. approx. with double hydrophilic guide tip

Guide wire with diameter 0.035 and length 450 cm. approx. with double hydrophilic guide tip

Guide wire of 0.025 and 0.035, hydrophilic tip with length of about 7 cm, total length 270 cm. and 450 cm., straight and angled tip

Guide wire of 0.025 and 0.035, hydrophilic tip with length of about 7 cm, total length 270 cm. and 450 cm., straight and angled tip

Bile dilators type Sohendra

Bile dilators type Sohendra

BILIARY BALLOON DILATOR

BILIARY BALLOON DILATOR

Wire-guided biliary toothbrush

Wire-guided biliary toothbrush

Oval loop with wide opening equipped with anti-slip teeth

Oval loop with wide opening equipped with anti-slip teeth

Sterile disposable bile biopsy forceps, with metal valves

Sterile disposable bile biopsy forceps, with metal valves

POLYPOSABLE BILIOPANCREATIC BIOPSY FORCEPS

POLYPOSABLE BILIOPANCREATIC BIOPSY FORCEPS

SYSTEM FOR CHOLEDOCHO-PANCREATOSCOPY

SYSTEM FOR CHOLEDOCHO-PANCREATOSCOPY

Anchor balloon for direct choledocoscopy

Anchor balloon for direct choledocoscopy

Sohendra type extractor

Sohendra type extractor

Loop certified exclusively for cold cutting

Loop certified exclusively for cold cutting

Loop certified exclusively for cold cutting, rotating,

Loop certified exclusively for cold cutting, rotating,

Rotating diathermic loop for polypectomy

Rotating diathermic loop for polypectomy

Multifunction forceps for resection of diminutive polyps,

Multifunction forceps for resection of diminutive polyps,

Double polyethylene prosthesis "PIG TAIL" for drainage

Double polyethylene prosthesis "PIG TAIL" for drainage

Biopsy forceps, fenestrated oval valves

Biopsy forceps, fenestrated oval valves

Biopsy forceps for pediatric gastroscope with oval valves, fenestrates, with and without needle

Biopsy forceps for pediatric gastroscope with oval valves, fenestrates, with and without needle

Caliper with rubberized valves

Caliper with rubberized valves

Scissor forceps used to cut stitches

Scissor forceps used to cut stitches

Cutter pliers for cutting distal loop wires

Cutter pliers for cutting distal loop wires

Foreign body removal forceps, alligator bite

Foreign body removal forceps, alligator bite

Mouse tooth foreign matter removal forceps

Mouse tooth foreign matter removal forceps

Forceps for foreign body removal tripod bite rings

Forceps for foreign body removal tripod bite rings

Forceps for removing foreign bodies alligator bite with mouse teeth

Forceps for removing foreign bodies alligator bite with mouse teeth

Rotating pliers for recovery with knurled valves with crocodile mouth and mouse teeth

Rotating pliers for recovery with knurled valves with crocodile mouth and mouse teeth

KIT containing double "PIG TAIL" prosthesis with introduction system, in sof-flex

KIT containing double "PIG TAIL" prosthesis with introduction system, in sof-flex

STERILE DISPOSABLE INJECTION NEEDLES

STERILE DISPOSABLE INJECTION NEEDLES

Stainless steel needle with sheath made for use with the duodenoscope

Stainless steel needle with sheath made for use with the duodenoscope

Injection needle from 21 to 25 G; with spring at the tip.

Injection needle from 21 to 25 G; with spring at the tip.

Bipolar coagulation probe for endoscopic hemostasis of non-varicose hemorrhagic lesions of the gastrointestinal tract

Bipolar coagulation probe for endoscopic hemostasis of non-varicose hemorrhagic lesions of the gastrointestinal tract

Catheter for bipolar electrohemostasis equipped with both a bipolar probe for hemostasis and an integrated needle for vaso-constrictor agent injection

Catheter for bipolar electrohemostasis equipped with both a bipolar probe for hemostasis and an integrated needle for vaso-constrictor agent injection

ESOPHAGEAL varicose veins tying system with elastic bands already mounted

ESOPHAGEAL varicose veins tying system with elastic bands already mounted

Preloaded endoclip, rotating and repositionable for hemostasis, of various sizes.

Preloaded endoclip, rotating and repositionable for hemostasis, of various sizes.

Preloaded endoclip, gradual and repositionable rotation for hemostasis and closure of wall defects

Preloaded endoclip, gradual and repositionable rotation for hemostasis and closure of wall defects

Preloaded endoclip, gradual rotation, repositionable for hemostasis with toothed morphology arms

Preloaded endoclip, gradual rotation, repositionable for hemostasis with toothed morphology arms

Endoclip for rotating hemostasis by washer on handpiece, removable with release mechanism, with double opening with snap

Endoclip for rotating hemostasis by washer on handpiece, removable with release mechanism, with double opening with snap

DISPOSABLE STERILE EXPANDABLE METAL BILITATIONS

DISPOSABLE STERILE EXPANDABLE METAL BILITATIONS

Disposable endoclip opening of 11 and 17 mm. with dedicated rotation system, independent of the opening, up to 360°, controllable by the doctor and repositionable several times.

Disposable endoclip opening of 11 and 17 mm. with dedicated rotation system, independent of the opening, up to 360°, controllable by the doctor and repositionable several times.

System for the treatment of lesions (perforations and fistulas) and bleeding of the gastrointestinal wall, including ENDOCLIP

System for the treatment of lesions (perforations and fistulas) and bleeding of the gastrointestinal wall, including ENDOCLIP

ANCHOR CLAMP

ANCHOR CLAMP

TWO-BITE PLIERS

TWO-BITE PLIERS

Pre-mounted nitinol clip on an applicator cap that is mounted on the tip of the endoscope and connected to the rotating handpiece for release through a special wire, designated for anchoring self-expandable metal stents

Pre-mounted nitinol clip on an applicator cap that is mounted on the tip of the endoscope and connected to the rotating handpiece for release through a special wire, designated for anchoring self-expandable metal stents

Disposable probes with integrated filter for argon gas coagulator + adapter

Disposable probes with integrated filter for argon gas coagulator + adapter

COMPLETE SET OF STERILE DISPOSABLE "ENDOLOOP" BINDING SYSTEM

COMPLETE SET OF STERILE DISPOSABLE "ENDOLOOP" BINDING SYSTEM

Ready-to-use biocompatible haemostatic gel

Ready-to-use biocompatible haemostatic gel

Sengstaken - blackmore hemostasis probes

Sengstaken - blackmore hemostasis probes

BALLOON DILATORS, DISPOSABLE, STERILE, FOR ESOPHAGUS-PYLOR-COLON DILATATION

BALLOON DILATORS, DISPOSABLE, STERILE, FOR ESOPHAGUS-PYLOR-COLON DILATATION

STERILE DISPOSABLE EXPANDABLE METAL ENTERAL PROSTHESES

STERILE DISPOSABLE EXPANDABLE METAL ENTERAL PROSTHESES

SET OF ACHALASIA FLASKS + PUMP

SET OF ACHALASIA FLASKS + PUMP

COMPLETE SET OF SAVARY DILATORS FOR ESOPHAGUS.

COMPLETE SET OF SAVARY DILATORS FOR ESOPHAGUS.

Probes with removable PULL method for traction, in silicone or similar material

Probes with removable PULL method for traction, in silicone or similar material

PEG REPLACEMENT PROBE WITH BALLOON ANCHOR

PEG REPLACEMENT PROBE WITH BALLOON ANCHOR

Y-replacement fittings for PEG

Y-replacement fittings for PEG

BUTTONS FOR ENDOSCOPIC GASTROSTOMY

BUTTONS FOR ENDOSCOPIC GASTROSTOMY

transparent polyurethane catheter for insertion into the jejunal loop with ENFIT seldinger attack technique

transparent polyurethane catheter for insertion into the jejunal loop with ENFIT seldinger attack technique

Fasting feeding tube to be used through percutaneous gastrostomy, compatible with Enfit fitting.

Fasting feeding tube to be used through percutaneous gastrostomy, compatible with Enfit fitting.

Percutaneous introduction system of gastrostomy probe with push technique to be used with balloon gastric probes for enteral nutrition.

Percutaneous introduction system of gastrostomy probe with push technique to be used with balloon gastric probes for enteral nutrition.

Kit consisting of: enteral feeding probe with atraumatic weighted tip in stainless steel or similar; flexible guide wire covered with Teflon; transfer cannula.

Kit consisting of: enteral feeding probe with atraumatic weighted tip in stainless steel or similar; flexible guide wire covered with Teflon; transfer cannula.

Self-expandable TTS esophageal prostheses partially covered and totally covered in silicone or similar, removable.

Self-expandable TTS esophageal prostheses partially covered and totally covered in silicone or similar, removable.

Fixing system for long-stay probes with positioning procedure type AMT BRIDLE.

Fixing system for long-stay probes with positioning procedure type AMT BRIDLE.

Probe for long-term enteral feeding (approx. three months)

Probe for long-term enteral feeding (approx. three months)

Polyurethane transnasal probe in three lumens for gastric decompression with ventilation and for enteral nutrition

Polyurethane transnasal probe in three lumens for gastric decompression with ventilation and for enteral nutrition

System for the recovery of polyps in multiple fragments or foreign bodies

System for the recovery of polyps in multiple fragments or foreign bodies

Transparent container for the recovery and identification of removed polyps

Transparent container for the recovery and identification of removed polyps

Protective bell for gastro-esophageal foreign bodies, to be applied to the terminal of the gastroscope.

Protective bell for gastro-esophageal foreign bodies, to be applied to the terminal of the gastroscope.

Needle with metal sheath for sclerotherapy

Needle with metal sheath for sclerotherapy

Bipolar coagulation probe for endoscopic hemostasis of the gastrointestinal tract.

Bipolar coagulation probe for endoscopic hemostasis of the gastrointestinal tract.

Mesh basket for octopus recovery

Mesh basket for octopus recovery

Polypectomy loop complete with relative handle, for enteroscope with coaxial system

Polypectomy loop complete with relative handle, for enteroscope with coaxial system

OTW esophageal prostheses with anti-migration system, self-expandable, self-conforming completely covered and removable with double proximal and distal suture thread for extraction.

OTW esophageal prostheses with anti-migration system, self-expandable, self-conforming completely covered and removable with double proximal and distal suture thread for extraction.

Biopsy forceps, oval valve with needle, for coaxial system enteroscope

Biopsy forceps, oval valve with needle, for coaxial system enteroscope

Probe for enteroscope with coaxial system, compatible with Argon Plasma Coagulator in use in the various areas of the customer

Probe for enteroscope with coaxial system, compatible with Argon Plasma Coagulator in use in the various areas of the customer

Sterile disposable system for placement of endoclips for hemostasis, preloaded.

Sterile disposable system for placement of endoclips for hemostasis, preloaded.

Fine Needle Needle Aspiration Cytology

Fine Needle Needle Aspiration Cytology

19 G flexible nitinol endoscopic ultrasound aspiration/biopsy needle.

19 G flexible nitinol endoscopic ultrasound aspiration/biopsy needle.

Needle Biopsy and cytological histological collection.

Needle Biopsy and cytological histological collection.

Fully covered self-expandable metal prostheses type lumen apposing

Fully covered self-expandable metal prostheses type lumen apposing

Self-expanding metal prostheses for ultrasound-guided drainage dedicated to hepatic gastroanastomosis.

Self-expanding metal prostheses for ultrasound-guided drainage dedicated to hepatic gastroanastomosis.

Cistotome with diathermic metal tip

Cistotome with diathermic metal tip

20 G needle for celiac plexus neurolysis

20 G needle for celiac plexus neurolysis

OTW self-expandable esophageal prosthesis with metal mesh, partially covered and totally covered in silicone or PTFE or similar

OTW self-expandable esophageal prosthesis with metal mesh, partially covered and totally covered in silicone or PTFE or similar

Ago precaricato precaricato con FIDUCIAL in oro

Ago precaricato precaricato con FIDUCIAL in oro

Forceps give Moray type biopsy

Forceps give Moray type biopsy

Linear and radial echoscope balloon compatible with Fuji, Pentax, Olympus echoendoscopes

Linear and radial echoscope balloon compatible with Fuji, Pentax, Olympus echoendoscopes

Multifunction catheter for endoscopic necrosectomy

Multifunction catheter for endoscopic necrosectomy

Endoscopic system for non-thermal mechanical necrosectomy of pancreatic collections by rotating probe

Endoscopic system for non-thermal mechanical necrosectomy of pancreatic collections by rotating probe

ENDOSCOPIC OBESITY TREATMENT KIT (BALLOON + NEEDLE + FORCEPS)

ENDOSCOPIC OBESITY TREATMENT KIT (BALLOON + NEEDLE + FORCEPS)

Kit for endoscopic gastric plication, without incisions, for the treatment of primary obesity

Kit for endoscopic gastric plication, without incisions, for the treatment of primary obesity

Disposable marker made of ready-to-use charcoal in syringe for marking lesions of the digestive tract.

Disposable marker made of ready-to-use charcoal in syringe for marking lesions of the digestive tract.

KIT FOR PERFORMING ORIENTED BIOPSIES

KIT FOR PERFORMING ORIENTED BIOPSIES

Disposable endoscopic valve set for suction, insuflation/irrigation, biopsy compatible with Olympus, Fujinon and Pentax endoscopes

Disposable endoscopic valve set for suction, insuflation/irrigation, biopsy compatible with Olympus, Fujinon and Pentax endoscopes

OTW self-expanding stent in nitinol completely covered in silicone also composed of polyurethane foam sponge and catheter in luer lock connection and Y connection for the pump.

OTW self-expanding stent in nitinol completely covered in silicone also composed of polyurethane foam sponge and catheter in luer lock connection and Y connection for the pump.

Valve with irrigation line for washing pump with connection to the operating channel adaptable to any type of endoscope.

Valve with irrigation line for washing pump with connection to the operating channel adaptable to any type of endoscope.

Adult mouthpiece with and without fastening strap.

Adult mouthpiece with and without fastening strap.

Mouthpiece for paediatric use with and without fastening strap

Mouthpiece for paediatric use with and without fastening strap

Adult mouthpiece with fixing strap with O2 oxygen connection

Adult mouthpiece with fixing strap with O2 oxygen connection

Cannulas with distal end able to carry out the vital coloring of the mucosa with spray effect.

Cannulas with distal end able to carry out the vital coloring of the mucosa with spray effect.

ENDOSCOPE CLEANING SYSTEMS

ENDOSCOPE CLEANING SYSTEMS

DIGESTIVE PATHOPHYSIOLOGY STUDY MATERIAL compatible with Menfis DYNO SMART equipment

DIGESTIVE PATHOPHYSIOLOGY STUDY MATERIAL compatible with Menfis DYNO SMART equipment

Catheter for impedance planimetry

Catheter for impedance planimetry

pH impedance probe to monitor and measure gastro-oesophageal reflux

pH impedance probe to monitor and measure gastro-oesophageal reflux

Ago da dissezione tipo Hook Knife

Ago da dissezione tipo Hook Knife

Download full details as .pdf
The Buyer:
AZIENDA USL DELLA ROMAGNA
CPV Code(s):
33190000 - Miscellaneous medical devices and products