Open procedure telematic tender for the supply of Medical Devices and specialized prosthetics for Thoracic Surgery divided into 34 batches for a period of 3 years
Endobronchial Prostheses and Accessories IGC 8952995532Endobronchial Prostheses and Accessories IGC 8952995532
CIG 8953103E4FDisposable balloon catheter with double coaxial hollow stem, to inflate the balloon and allow, if necessary, the use of guide wire to introduce and position the catheter.
Balloon with 2 radiopaque markers at the ends and centimeter markers on the catheter. Miscellaneous measures
Including inflation system.
CIG 8953113692Disposable sterile catheter, used to deliver heated water vapor from the Generator to the airway to be treated, with the following characteristics: Quick coupling for fixing to the generator handpiece. Balloon in the distal part for occlusion area to be treated. Two ways. Diameter 2.6 mm. Length 800 mm Accessories
• Non-sterile drainage bag for treatment liquid collection 2 lt. with tube and one-way quick coupling.
The Steam Generator will be used free of charge for each procedure.
CIG 895313049ASterile talc for chemical pleurodesis free of Asbestos with controlled grain size, ready to use sterile.
CIG 89531461CFResector flask in polyurethane, expandable, with suction system, diameter 10/15/20 mm for resection, dilation and haemostasis. Catheter length 120 cm. The material must be supplied sterile.
CIG 8953157AE0Disposable laser fibers compatible with Leonardo Dual 100 Laser supplied to the department.
• 600 µm fiber for remote use Ø 1.4mm length 3.5m with washing channel.
• 1000 µm fiber in contact complete with handpiece Length 2.6m.
CIG 895316517DDisposable laser fibers compatible with the Dornier Fibertom 8100 YAG Laser supplied to the department.
• 600 µm fiber for use at a distance Ø 2.2 mm, length 3.5 m with washing channel.
• 600 µm fiber in contact Length 3.5m
8953176 TO 8ESuction tubes diam 2,3 and 4 mm 60cm long for rigid bronchoscopy
CIG 89531873A4EBUS SYSTEM —TBNA (Trans-Bronchial Aspiration Needle). Nitinol needle about 22G, needle length 4 cm. Maximum device outer diameter 1.9 mm, operating length 700 mm.
CIG 89532041ACEndoscopic endoscopic endoscopy biopsy needle of about 22G with lateral window of about 1.5 mm located about 2mm from the tip for histological survey. Compatible with Olympus instruments
CIG 89532149EATeflon-coated 3 or 4-wire foreign body recovery pliers with ergonomic three-ring handle. Measurements: 150cm length and 2.3mm diameter
PTFE mesh with a single lamellar structure and differentiated porosity surfaces, can be shaped, suitable for the repair of the chest wall and as a reinforcement: thickness 2 mm. CIG 8953006E43PTFE mesh with a single lamellar structure and differentiated porosity surfaces, can be shaped, suitable for the repair of the chest wall and as a reinforcement: thickness 2 mm. CIG 8953006E43
CIG 895322315ATeflon-coated biopsy forceps for histological collection with ergonomic three-ring handle and oval grip. Measurements: 120cm length and 2.3mm diameter
CIG 895323071FSystem for minimally invasive correction of Pectus Excavatum and Pectus Carinatum composed of medical surgical steel bars with atraumatic smooth ends of various sizes and low profile high profile stabilizers smoothness with integrated fixing system. Possibility to have custom made bars covered with titanium alloy or other hypoallergenic material. Case Type for economic offer presentation: 1 bar, 1 stabilizer with fixing system
CIG. 8953242108Osteosynthesis system for traumatology and rib and sternal reconstruction exclusively in titanium composed of clips and bars without screws or fixing pins.
The adjustable system must have components of different sizes and angles that allow optimal longitudinal and transverse stabilization of the chest wall and sternum. Standard case for presentation of economic offer: reconstruction of 3 coasts.
CIG 895326325CSternum Reconstruction System and Osteosynthesis Fixation System
CIG 895326974ESterile silicone elastomer chest prosthesis, custom-made customizable measures, for the treatment of Poland Syndrome or for hypogenesis or agenesis of the pectoral muscles. Case type: a prosthesis
CIG 8953275C40Fully electronic/digital cardio-thoracic drainage system with dry valve, with display to monitor air and drained fluid leaks.
Possibility to view the last 72 hours of each type of loss directly on the device display. Possibility of charging resting on the charging station to facilitate the walking of patients being treated.
CIG 8953281137Aerostasis sealant of the damaged lung parenchyma.
CIG 89533119F6Bovine collagen sealing/haemostatic patch with amino protein and polyethylene glycol coating
CIG 8953321239Non-stick film consisting of carboxymethyl cellulose and sodium hyalunorate
CIG 89533298D1Disposable toothbrush with protection system on the distal end to protect the endoscope channel, for cleaning the channel of the Olympus fibro-video-bronchoscope. Channel size 2mm/2.8 mm
PTFE membrane with a single lamellar structure and differentiated porosity surfaces, can be shaped, suitable for the repair of the diaphragm CIG 8953016686PTFE membrane with a single lamellar structure and differentiated porosity surfaces, can be shaped, suitable for the repair of the diaphragm CIG 8953016686
CIG 89533477ACDisposable Biopsy Valve Multipurpose Toothbrush Disposable Latex Sheath (Balloon)
CIG 8953354D71EBUS TBNA Needle Adapter Valve
CIG 895336240EProbe in flexible plastic material, for bronchoalveolar washing, channel diameter 2 mm
CIG 8953368900Disposable balloon catheter for endobronchial contact haemostasis, compatible operating channel 2 mm, operating length 1050 mm, balloon diameter 11 mm and Endobronchial cytology brush (brushing) disposable.
CIG 895338248FDisposable biopsy forceps with double step valve, for non-contaminated endobronchial sampling, compatible operating channel 2.0/2.8 mm, adequate operating length, covered with external sheath to promote insertion into the channel of the fibro-video-bronchoscope;
Cross-Link porcine pericardium patch, with anti-release glutaraldehyde residue treatment, ready to use without the need for rinsing. Measure 8 x 14 cm CIG 8953036707Cross-Link porcine pericardium patch, with anti-release glutaraldehyde residue treatment, ready to use without the need for rinsing. Measure 8 x 14 cm CIG 8953036707
CIG 8953043CCCExpanded PTFE membrane 0.1 mm thick to be used as a substitute for the pericardium to isolate the heart structure, pore diameter less than one micron to prevent the creation of adhesions: measures 12 x 12 cm CIG 8953043CCC
CIG 895305243CHydrated bovine pericardium patch, with antimicrobial treatment using glutaraldehyde for prion inactivation but with very low release of amino residues, biocompatible, anti-adhesion and anti- calcification, resistant to biodegradation, nonyrogenic, similar to autologous tissue, ready to use, able to re-approximate around sutures IGC 895305243C
CIG 8953063D4DTracheobronchial prosthesis in medical silicone, anchoring with radiopaque feet. CIG 8953063D4D
CIG 89530713EAEndotracheal Prosthesis and Bronchial Prostheses
CIG 895309253ECap made of silicone and intended for bronchial occlusion in the treatment of various bronchus pleural lung diseases.