Repair and maintenance services of medical equipment | Tenderlake

Repair and maintenance services of medical equipment

Contract Value:
-
Notice Type:
Contract Notice
Published Date:
22 August 2019
Closing Date:
25 September 2019
Location(s):
PL225 Bielski (PL Poland/POLSKA)
Description:
Provision of post-warranty service for radiotherapeutic equipment of the manufacturer Varian Medical Systems together with accompanying devices, installed in BCO-SM in Bielsko-Biała

The subject of the order is the provision of post-warranty service for radiotherapeutic equipment of the manufacturer Varian Medical Systems together with accompanying devices installed at the Radiotherapy Plant of the Beskid Oncology Center-City Hospital in Bielsko-Biała.

The subject of the order is the provision of post-warranty service for radiotherapeutic equipment of the manufacturer Varian Medical Systems together with accompanying devices installed in the Radiotherapy Plant of the Beskid Oncology Center-City Hospital in Bielsko-Biała in the scope of:

- Clinac 2300CD Silhouette S / N: 954 accelerator with MLC120 multi-leaf collimator, Portal Vision aS500 imaging system, Exact therapeutic table, Aria Treat system, Laser centrators - 3 pcs, monitor in the therapy room,

- Clinac 2300CD Silhouette S / N: 859 accelerator with MLC120 multi-leaf collimator, Portal Vision aS500 visualization system, Exact therapeutic table, Aria Treat system, 3 laser centers, monitor in the LCD therapy room,

- Clinac iX S / N: 1023 accelerator with multi-leaf collimator MLC120, Exact therapeutic table, Portal Vision aS1000 visualization system, Aria Treat system, OBI radiographic system, 3 laser centers, monitor in the therapy room,

- VitalBeam S / N: 3248 accelerator with MLC120 multi-leaf collimator, Portal Vision aS1200 visualization system, RapidArc option, VCD option, RG option, 3 laser centers, monitor in the therapy room,

- Acuity iX S / N: 265 radiotherapy simulator with equipment,

- Acuity iX S / N: 420 radiotherapeutic simulator with CBCT CTCT option of the Acuity Simulator with equipment,

- Aria Eclipse HIT 3583 radiotherapy management system and treatment planning with the Aria system server, DELL PowerEdge R820 server, disk array, IBM LTO5 streamer, DELL 2700W UPS, 8 station ARIAEDIT system, 5 unit Eclipse station, Eclipse BrachyVision 1 station piece, SomaVision system station 4 pieces, active elements of the computer network: switch 3Com 24x10 / 100 + 2x1000Base-T, UPS 1000VA

- RGSC HGS2167– Respiratory Gating for Scanner - an advanced respiratory synchronization system.

Download full details as .pdf
The Buyer:
Beskidzkie Centrum Onkologii - Szpital Miejski im. Jana Pawła II w Bielsku-Białej
CPV Code(s):
50421000 - Repair and maintenance services of medical equipment