Miscellaneous medical devices and products | Tenderlake

Miscellaneous medical devices and products

Contract Value:
-
Notice Type:
Contract Notice
Published Date:
22 September 2023
Closing Date:
31 October 2023
Location(s):
PL POLSKA (PL Poland/POLSKA)
Description:
Delivery of sterile medical devices used in the Neonatal Ward and the Obstetrics and Gynecology Clinic.

1. The subject of the contract is: Delivery of sterile medical devices used in the Neonatal Ward and the Obstetrics and Gynaecology Clinic.

2. The subject of the contract has been divided into 32 lots. The contracting authority allows partial bids to be submitted.

3. A detailed description and manner of execution of the order is included in the OPZ, constituting Annex 1-32 to the SWZ. The contractor may submit a bid for any number of tasks.

Task No. 1

1 Polypropylene newborn feeding bottle (not containing bisephenol A), drink. 130 ml, for storing breast milk and feeding, sterile, individually packed in bags. Opak 100 pcs. Suitable for Medela breast pumps. 16 000 pcs

2 Polypropylene bottle (free of bisephenol A and phthalates), poj. 50 ml for storing breast milk and feeding,sterile, individually packed in bags. Opak 200 pcs. Suitable for Medela breast pumps. 21 000 pcs

Task No. 10

1. Endotracheal tube stabilizer designed for premature babies and newborns, free of latex and BPA, preventing palate injuries, easy to remove in case of emergency. Fastening with a hydrocolloid patch, fixing plasters must not be located directly at the mouth of the newborn. Possibility of maintenance up to 1 week. Included tape measure for easy selection of the right size. Sizes depending on the weight of the newborn: up to 600g; 600-800g; 800-1200g; 1200-1500g; 1500-2000g; above 2000g. Bulk packaging max. 5 pcs.-140 pcs.

2 Bacterial and noise suppression filter for gas flow.-150pcs.

3 nCPAP adapter/connector for Fabian ventilator, Fabian Therapy device, 0.6m long. -160pcs.

4 Respiratory system for resustitation with heated arm, novating chamber, T-valve – compatible with MR850 humidifiers owned by the Ordering Party10pcs.

Task No. 11

1 Standard teats – for full-term newborns, simple – without chokeins, standard shape, made of TPE – thermoplastic elastomer, without latex and without Bisephenol A, with vent hole. Individually packed with a nut (4 cm diameter nut), color-coded, with three holes – medium milk flow, usable length 3.5 cm, disposable. Pack max 100 pcs.-2 000pcs.

2Symphony breast pump collection kit. For one day or up to 8 pumps. Ready to use. Microbiologically pure. made of polypropylene, free of Biseptol A or phthalates.

Included:

• a connector with a removable funnel enters,

• drain at avg. 4mm connected to the connector and piston cap;

• removable membrane surrounding the edges of the cap for full tightness after applying to the piston;

• possibility of using 24, 27 and 30mm funnels.

Compatible with all standard thread bottles, paper-foil packaging, containing information about production date, expiration date, LOT number and reference number. Individually packed - 1 600pcs.

3 Bacterial filter for nebulizer: compatible with inhalers: MEDEL PRO, MEDEL MAXI, MEDEL PRO – MINI, has anti-infective and antibacterial effects, disposable product. Pack of 10 pcs.-120pcs.

Task No. 12

1. Newborn earphones designed to protect hearing -50pcs.

2 Covers for temperature sensor, dimensions:

2a 2,5 x 2,5 cm 50pcs

2b 3,5 x 3,5 cm 50pcs

3. Urine collection bags for boys and girls. Disposable, For use in newborns. No adhesives. Hypoallergenic. After application, it adheres well to the patient's skin. Persisting on the skin of the newborn only on the principle of adhesion adhesion phenomenon thanks to the use of a thin layer of silicone. Universal use: for boys and girls. Available in two capacities: 75ml and 100ml. Individually packed, individually. Not causing chafing. Visible scale on the bag to measure the volume of urine collected. On the wrapping: name, manufacturer, batch number, catalogue number, expiry date. In a collective package of 50 pieces. 500 pcs.

per piston;

• removable membrane surrounding the edges of the cap for full tightness after applying to the piston;

• possibility of using 24, 27 and 30mm funnels.

Compatible with all standard thread bottles, paper-foil packaging, containing information about production date, expiration date, LOT number and reference number. Individually packed - 1 600pcs.

3 Bacterial filter for nebulizer: compatible with inhalers: MEDEL PRO, MEDEL MAXI, MEDEL PRO – MINI, has anti-infective and antibacterial effects, disposable product. Pack of 10 pcs.-120pcs.

Task No. 13

1. Insulating bag (newborn, polyurethane bag), size 38 x 30 cm closure by pulling ribbons. Each bag packed individually, multipack 10 pcs. -250 pcs.

2. Insulating bag (newborn, polyurethane bag), size 44 x 38 cm closure by pulling ribbons. Each bag packed individually, multipack 10 pcs. -20pcs.

3. Set for inserting a catheter into the vein of a newborn from a Premicath type circuit. Transcutaneous microcatheter with a mandrin inserted peripherally, intended for chronic use, made of polyurethane, shading in X-ray, marker, every 1 cm with a size of 1F (0.15 x 0.3 mm) and a length of 20 cm. Catheter terminated with flexible wings. Built-in catheter protection against bending of the catheter lumen. Catheter inserted with a burstable needle 24G, sterile.- 50pcs.

Task No. 14

1. Paediatric chest drainage kit -10 pcs.

2. Pleural drainage kit -100 pcs.

Task No. 15

1. Disposable respiratory system for Neopuff without mask, including inspiratory arm not heated, inspiratory line length min. 120 cm, at the end of the system there must be a PEEP valve, the entrance to the valve with an internal diameter. 15 mm, date of manufacture on the package-550 pcs.

2 Respiratory masks for Neopuff, in sizes:

2a 490 -40pcs.

2B 50mm-300pcs

2c 60 mm 200

3 Patches to protect the nose of the newborn during intranasal ventilation. Patches protecting the delicate skin of the nasal septum and nostrils, improve the seal maintaining the effectiveness of CPAP, Infant-F low, do not contain latex, phthalates (DEHP and BPA). Micro (length 20 mm, width 10 mm), small (length 25 mm, width 12.5 mm) and large (length 30.5 mm) packaging: 150 pcs.-1,000 pcs.

4. Hydrocolloid patch, disposable, to protect the nose during the use of neonatal masks for nCPAP ventilation in the shape of a connected triangle with the letter T. Small and large size, package 20 pcs.-440 pcs.

Task No. 16

1. Tuberculin syringe with needle. Sterile, disposable, airtight. Three-piece, transparent cylinder accurately showing the contents of the syringe, made of polypropylene. Easy and even piston movement, piston extension protection ring for good visibility of the contents, accurate and visible determination of administered doses, scale every 0.01 ml, luer joint, needle size 0.45 x 10 mm. Individually packed with needle included. Pack of 120 pcs.-100pcs.

2. Three-way faucet. Sterile, disposable, non-toxic, transparent housing, three-arm knob white, having an optical and perceptible position indicator in each position, does not contain latex (manufacturer's designation on the unit packaging), independently rotating Luer-Lock nut, all tap inputs secured with corks, resistant to cracking. Pack max 100 pcs.-100 pcs.

3. Three-way tap with drain (extension cord 9 cm + 2 cm). Sterile, disposable, non-toxic, transparent housing, three-spoke knob, white, having an optical and perceptible position indicator in each position, does not contain latex (manufacturer's designation on the unit packaging), all tap inputs protected with corks, resistant to cracking. Pack max 50 pcs.-100 pcs.

4. Picc catheter stabilizing device for adults. Seamless attachment of catheters to central punctures, crescent-shaped foam pad, designed to minimize complications from catheter movement, eliminates suture protection and accidental needle. It has sliding "posts" for placing the catheter in the stabilizer. Pack of 50 pcs. -18 pcs.

Task No. 17

A cannula for puncture of the pericardium and conducting rapid infusions inserted into the central veins or large peripheral vessels of roses. 18G x 90mm; 16G x 130mm; 16G x 160mm, 14G x 160mm with sliding ball shut-off valve, pre-puncture mandryn and stabilizing wings-50 pcs.

Task No. 18

Sharp-sharp surgical scissors straight 14.5 cm. For cutting the frenulum in newborns. Made of durable brushed anti-reflective steel. Disposable sterile tool, ready to use. Op. 25 pcs.-250 pcs.

Task No. 19

1. Pacifier, latex free, sterile, premature size. Awry. 100 pcs. Blue. On the lid of the package there is an expiration date and flight number. Latex-free teat with reduced milk flow. The offered pacifier is suitable for use from the first day of the baby's life. The pacifiers fit all bottles from Sterifeed, Ameda and others, with a standard screw cap diameter of 7,000 pcs.

2. Newborn pacifier, latex free, sterile, standard size. Awry. 100 pcs. Red. On the lid of the package there is an expiration date and flight number. Latex-free teat with medium milk flow. The offered pacifier is suitable for use from the first day of the baby's life. The teats fit all bottles from Sterifeed, Ameda and others, with a standard screw cap diameter of 6,000 pcs.

Task No. 2

Newborn kit containing:

• absorbent base made of cellulose pulp 60x60cm (+/-2cm)

• non-woven napkin 80 x 60cm (+/- 2cm), 40g/m², absorbency 900% - 2 pcs;

• cap for newborns, circumference 20cm (+/- 1cm), height 12cm (+/- 1cm), made of knitted fabric, 100% cotton – 1 pc;

• flannel blanket 160x75cm (+/-2cm) - 1pc;

• measuring tape 70cm (+/- 5 cm) - 1 pc.

Set sterilized in ethylene oxide, packed in a paper-foil bag with a double self-adhesive label containing information: name of manufacturer, expiration date, batch number.

Awry. 12 pcs. 3 000 pcs

Umbilical cord clamp cutting kit containing:

• gas compress 17N 8W 7,5 x7,5 cm – 3 pcs;

• device for cutting umbilical cord terminals – 1 pc

The set is packed in a hard blister packaging, fulfilling the function of a 10x20 cm container, sterile, disposable. Awry. 25 pcs.

800 pcs.

Task No. 20

1. Nasal cannula for high flow therapy, with fixing pad, with soft nasal arms made of silicone. In the paranasal part, a protrusion allowing for an aseptic adjustment to the nostrils. Two independently adjustable fixing pads attached under the nose, glued to the skin with anti-allergic, silicone medical tape, which allow correction of the cannula position and its removal. Latex-free cannula, intended for MRI examinations. Sizes: premature, flow 1-8L; neonatal, flow 1-8L; infant, flow 1-10L; infant large, flow 1-20L: pediatric, flow 1-25L.-30pcs.

Task No. 21

1. Neonatal system with humidifier chamber, universal. Heated inspiratory section 1.2 m long, unheated exhaust section with water trap, extension section to the incubator 0.3 m long, pressure drain 1.5 m long, adapter set, port for supply and NO measurement. Humidifier chamber with a design to prevent excessive accumulation of condensate in the breathing circuit with a drain supplying water 1.2m - 20 pcs.

Task No. 22

Disposable obstetric vacuum pipe, having a properly contoured, ergonomic handle, with an indicator of the value of the vacuum created in the form of a legible graduation and an easily accessible vacuum release valve. The thrust indicator avoids exceeding the safe value and thus reduces the possibility of complications. The flexible connection between the pelota and the handle allows for trouble-free maneuvering and proper placement of the pellet. Atraumatic mushroom-shaped cups with a diameter of 50mm are available, suitable for use in any fetal position and caesarean section, or flexible bell-shaped soft cups with a diameter of 59mm-60 pcs.

Task No. 23

Puncture needles for ovarian biopsy, single-light manual puncture needles with Luer Lock termination, without cord. The connector allows you to connect the syringe as well as directly the cable itself. The lancet needle blade has an echogenic tip and a blade in a shape that ensures atraumaticism. Size: 16G x 330mm. Pack of 10 pcs. -400 pcs.

Task No. 24

Set of disposable guides Ultra – Pro II. The set includes 24 sets. Guides. Aseptic needle guide with 3.5 x 20 cm (1.4" x 7.9") latex shield, slide fits 16 - 18GA instruments, needle length is 18 cm (7.1"). Ultra-Pro II slide inserts, CIV-Flex probe and probe cable covers, telescopically folded 14 x 91.5 cm, ultrasound gel, flexible fastening bands Multipack containing 24 sets - 72 pcs.

Task No. 25

1. 5mm device for fixation of hernia meshes with 15 absorbable, spiral screws. Staple size: height 5.1mm; active staple height 4.1mm. Total absorption time up to about 1 year after implantation. Awry. 6 pcs.- 6 pcs.

2 5 mm device for fixation of hernia meshes with 30 absorbable, spiral screws. Staple size: height 5.1mm; active staple height 4.1mm. Total absorption time up to about 1 year after implantation. Awry. 6 pcs - 6 pcs.

3 Disposable, reinforced microwave ablation electrode, generator compatible, length 15cm; 20cm; 30cm. The length of the radiation zone is 2.8 cm, ceramic tip, cooled shield with markers every 1 cm, additional markers every 5 cm, 2 clips / clips on the electrode cable enabling its stabilization by connecting it to the material that the patient is covered. Orange pump tubing with liquid/coolant direction markers - 30 pcs.

Task No. 26

Rapid immunochromatographic immersion test for the detection of premature rupture of fetal membranes. The package contains test strips packed individually, with desiccant, sterile swabs, tubes with extraction buffer.-270 pcs.

Task No. 27

1. Laparoscopic (LAP) pump drain, rinsing with two needles compatible with Karl Storz pump type Hamou Endomat (type 26331120), for laparoscopic procedures, sterile, disposable, op. max 10 pcs.-2 op.

2. Hysteroscopic (HYS) pump drain, rinsing with two needles, compatible with Karl Storz pump type Hamou Endomat (type 26331120), for hysteroscopic procedures, sterile, disposable, op. max 10 pcs. -13 op.

3. Suction and rinsing drain set, compatible with Storz pistol grips owned by the Ordering Party, sterile set, disposable, op. max 10 pcs. -1op.

Task No. 28

Table-tube splinting set type Double-J. Catheter size 6 Fr. The kit includes a double pigtail catheter, clamps, pusher, guide, guide cap. Distance between loops 26 cm; chain diameter 0.035"", chain length 110 cm. -50 pcs.

Task No. 29

1. Bipolar probe straight microfork (working length 4.5 cm, wire 3 m) for direct nerve stimulation, disposable product, bulk packaging 10 pcs.-3 op.

2. 4-channel electrode glued on endotracheal tubes 7-0, electrode surface 37x37 neutral electrode included, multipack 10 pcs-3 op.

Exercise NR 3

1. Scissors for cutting the umbilical cord, metal, disposable, sterile, individually packed in dispensers of max. 25 pcs. 1,625 pcs

2. Central puncture set, packed in a rigid blister pack serving as a container, on the outside of the package there is a label with a minimum of two TAG labels to be pasted into the medical documentation.

Set line-up:

• tablecloth made of waterproof laminate 45x75cm,

• tablecloth made of 2-layer laminate 45x75cm with hole diameter. 8 cm and adhesive around the hole,

• gauze compresses 17N, 8W 7,5x7,5cm - 10 pieces,

• tupfer ball -10 pieces,

• plastic pennet 13 cm - 1 piece,

• 10ml syringe,

• 20ml syringe,

• needle 1.2x40mm,

• needle 0,8x40mm,

• blade No. 11,

• metal forceps for needle 13 cm. 1 000

3 Lumbar puncture kit, packed in a rigid blister pack serving as a container, on the outside of the package there is a label with a minimum of two TAG labels to be pasted into the medical records.

Set line-up:

• serweta foliowana 75x45cm,

• 2layer laminate napkin. 50x60cm with a 10cm hole and 2 adhesives on the corners,

• syringe 3ml,

• strzykawka 5ml LL,

• plastic penseta 13 cm,

• needle 1.2x40mm,

• needle 0,5x25mm,

• non-woven compress 30 grams, 4W 7.5x7.5cm - 10 pieces.

Island dressing 5x7,2cm. -1 800 pcs

Task No. 30

Endosampler - A probe for taking material from the cervix and uterine cavity. The kit includes a sterile 10ml syringe with a self-locking plunger and a folded probe with graduation and a large 6mm hole for collecting material from the cervix. Probe screwed into the syringe with markers every 1cm. The set does not include a stopper and a limiter-270 op.

Task No. 31

Bakri balloon for the treatment of postpartum hemorrhages. 100% silicone design, latex-free, easy-to-place catheter avoids threatening hysterectomy, includes syringe 60ml, 24 Fr, length 54cm, polymer hose, infusion bag spike and three-way valve, maximum filling volume 500ml.-8pcs.

Task No. 32

Endorette (pipelle). Disposable sterile endorette for collecting material from the uterine cavity and other body cavities. For aspiration biopsy of the endometrium, sterile. 4 holes. Length 26.5 cm. Flat handle 3cm-100pcs

Task No. 4

11. Disposable diapers for newborns and premature births, absorbent, airy, having a soft and delicate coating, providing the child with comfort and reducing the risk of skin irritation, having durable Velcro reusable fastening and cutting out has an umbilical cord stump, which allows you to avoid irritation of this place, packed in a max of 46 pcs.

Size from 0 to 2 kg.-30 000 pcs.

2. Disposable diapers for newborns and premature births, absorbent, airy, having a soft and delicate coating, providing the child with comfort and reducing the risk of skin irritation, having durable Velcro reusable fastening and cutting out has an umbilical cord stump, which allows you to avoid irritation of this place, packed in a max of 82 pcs.

Size from 2 to 5 kg.-40 000 pcs.

Task No. 5

1. Neonatal set for inserting catheters type PICC-50 pcs.

2. Set for inserting umbilical cannulas.-30 pcs.

3 Umbilical cannula. Neonatology, polyurethane cannula for vein and / or umbilical artery with an atraumatic distal tip, visible in X-ray, packed with a three-way tap forming an integral whole after connection and providing protection for the proximal tip of the cannula – due to the long period of use (up to 3 weeks). Size to choose by the ordering party from the range: 2.5F – length 30cm (outer diameter 0.5mm); 3.5F (outer diameter 0.8mm); 4F (outer diameter 0.8); 5F (outer diameter 1.5mm) – cannula length 40 cm. -120pcs.

4 Endotracheal tube for surfactant administration: without balloon, dual-light, designed for long-term intubation, opaque, soft, made of thermoplastic material adapting to the shape of the respiratory tract with a strip contrasting in X-ray and 25mm distal tip also contrasting in X-ray, marked with a length of 0.5cm. Individually packed, sterile, disposable. Size no 2,0; No 2.5; No 3.0; No 3.5; No 4.0; No. 4,5. -130 pcs.

5 Exchange transfusion set - 8 pcs.

6 Catheter for administering surfactant by the Lisa method. Catheter length 20 cm in size 6 Fr. Catheter tip bent at 30º in black. Marking on the catheter every 1 cm and every 5 cm-35 pcs.

Task No. 6

1. Disposable paediatric intubation tubes with full graduation from 0, without sealing cuff, oro-nasal, Murphy type. Made of thermoplastic PVC, transparent, X-ray line along the entire length of the tube, without latex and phthalates. Size from 2.0 to 4.0.-220 pcs.

2 Sensor in patented Masimo SET RD technology for newborns under 3kg, Sp O2 accuracy: 7-100% +/-1.5% during movement (confirmed by folder). L-type sensor with flesh-colored flexible wrapper, cable embedded in flat foam - 70 pcs.

3 Replaceable sensor tapes for newborns under 3kg, roll - 102 tapes-102 pcs.

4 Electrostatic filter for children up to 30kg, antibacterial, anti-virus with cap port protected by a cap on a TPE rope, with heat and moisture exchanger. Bacterial and viral filtration efficiency >99.99%, confirmed by protocols from independent laboratories. Gas distribution system over the entire filter surface, anti-occlusive protection mechanism, dead space 11 ml, weight 11 g, humidification capacity 26.8 ml H2O/l, flow resistance at @10L/min 1.0 cm H2O, tidal volume min. 35ml, straight connector 15M-15F, with a time of application 24h, packed individually - 100 pcs.

Task No. 7

1. Phototherapy glasses: made of soft, adjustable and transparent polyurethane film covered on one side with a soft silicone surface (not glue). The glasses are intended for use in patients with sensitive and delicate skin, i.e. newborns. They provide effective placement and completely painless removal. The gentle adhesion of the silicone gel layer ensures proper eye protection during phototherapy. . They do not contain latex. They do not contain glue. Thanks to the use of high-density black material, the glasses completely retain external light. The material in contact with the eye is pure cotton without the addition of dyes, pack. 50 pieces.

1a rozme XS 50 st.

1b size S 150 pcs.

1c size M 250 pcs.

Quest 8

Neo-natal neo-natal pulse oximetry sensor LNCS Neo L, single-patient with plug and cable length 46 cm in Masimo SET technology, for patients weighing less than 3 kg and over 40 kg, with the possibility of revitalizing the adhesive layer. For EDAN X8 cardiac monitors and RAD97-1100 pulse oximeter op.

Task 9

1. Disposable pads measuring 60 x 90 cm (+/- 1 cm) for changing newborns – having a soft, pleasant to the touch top non-woven fabric. The bottom part is foiled, waterproof. Packaging max. 30 pcs.-7 000s

2 Gastric tube for feeding a newborn through the nose: CH 06; 08, length up to 400mm. Non-toxic catheter, soft, rounded atraumatic end, alternating holes, anti-fracture design, including a connector with a plug with an X-ray thread. Sterile, disposable -500 pcs.

3 Cellulose towels 30x40 cm (+/- 3 cm), white; weight 50 g/m2 (+/-5g); made of airlaid material; characterized by strength during both dry and wet use; absorbent, soft, with very low dust; Package 30pcs.-3300pcs.

4 Non-woven towels 40x70 cm (+/- 3 cm), white; weight 50 g/m2 (+/-5g); made of viscose fibres with the addition of polyester or polypropylene; characterized by strength during both dry and wet use; absorbent, soft, with very low dust; not irritating the skin. Pack of 30 pcs.-1500 pcs.

Download full details as .pdf
The Buyer:
Samodzielny Publiczny Szpital Kliniczny Nr 1 w Lublinie
CPV Code(s):
33190000 - Miscellaneous medical devices and products