Specialist planning technical equipment, plant group 3, acc. §§ 55 ff. HOAI at the University of Duisburg-Essen on the Essen and Duisburg campuses.
Asbestos-containing fire dampers (BSK) were still found in various buildings on the Duisburg and Essen campuses. These asbestos-containing fire dampers are to be replaced. The exact number of fire dampers containing asbestos is not known. There are test reports in which asbestos-containing fire dampers are identified. The information is not complete and comprehensive. There are still reports from the maintenance company. Fire dampers containing asbestos are also identified in these reports. The information provided by the maintenance company is also not complete and comprehensive. The reports must be checked and the BSK must be inspected on site.
The BLB guidelines for handling "Fire dampers containing asbestos" must be observed and taken into account during planning. The TRGS guidelines must be observed and implemented during planning and implementation.
After completion of the work, it must be demonstrated by measurement according to VDI 3492 that a fiber concentration of 500 fibers / m
The asbestos-containing fire dampers must be replaced immediately and as soon as possible.
The fire dampers are replaced during operation. Maintenance intervals should be used whenever possible. The measures are to be coordinated with the user in terms of time and organization for each building in order to keep the restrictions as low as possible.
Please refer to the tender documents for more details.
Planning services for the technical equipment, plant group 3, service phases 1-3 and 5-9.
The order is optionally placed in stages.