Sanitary, ventilation and heating
for the new construction of four residential buildings (63 units)
2. BA White City,
Emil-Büge-Straße 2 A - 2 D in 16515 Oranienburg
House 2 ATHE 1 Haus 2 A:
approx. 300 m waste water pipe in building DN40-DN125,
approx. 55 m rainwater pipe with thermal insulation in the building DN100-DN125,
approx. 540 m drinking water pipe stainless steel with thermal insulation DN12-DN54,
ca. 385 m Trinkwasserleitung PE-HD DN12-DN25,
approx. 88 m internal circulation line,
19 pcs. bathroom with washbasin, toilet, bath or shower, washing machine connection, incl. fittings,
21 St. Einzelraumlüfter,
ca. 75 m Wickelfalzrohr DN80-DN140
approx. 315 m heating pipe stainless steel with thermal insulation DN15-DN50,
21 pcs heating circuit manifold with distribution cabinet,
approx. 1550 m² underfloor surface heating installation system,
House 2 BLot 2 House 2 B:
approx. 280 m waste water pipe in building DN56-DN110,
approx. 55 m rainwater pipe with thermal insulation in the building DN100-DN125,
approx. 500 m drinking water pipe stainless steel with thermal insulation DN12-DN54,
ca. 190 m Trinkwasserleitung PE-HD DN12-DN25,
approx. 60 m internal circulation line,
21 bathrooms with washbasin, WC, bathtub or shower, washing machine connection, incl. fittings,
13 St. Einzelraumlüfter,
ca. 50 m Wickelfalzrohr DN80-DN160
approx. 265 m heating pipe stainless steel with thermal insulation DN15-DN50,
13 pcs heating circuit distributor with distribution cabinet,
approx. 1200 m² underfloor surface heating installation system,
House 2 CLot 3 House 2 C:
approx. 240 m waste water pipe in building DN40-DN125,
approx. 60 m rainwater pipe with thermal insulation in the building DN100-DN125,
approx. 410 m drinking water pipe stainless steel with thermal insulation DN12-DN40,
ca. 225 m Trinkwasserleitung PE-HD DN12-DN25,
10 bathrooms with washbasin, WC, bathtub or shower, washing machine connection, incl. fittings,
10 St. Einzelraumlüfter,
ca. 40 m Wickelfalzrohr DN80-DN125
approx. 150 m heating pipe stainless steel with thermal insulation DN15-DN50,
10 pcs heating circuit distributor with distribution cabinet,
approx. 620 m² underfloor heating installation system,
House 2 DLot 4 House 2 D
approx. 181 m waste water pipe in building DN40-DN125,
approx. 56 m rainwater pipe with thermal insulation in building DN100-DN125,
approx. 350 m drinking water pipe stainless steel with thermal insulation DN12-DN40,
ca. 242 m Trinkwasserleitung PE-HD DN12-DN25,
19 pcs. bathroom with washbasin, toilet, bath or shower, washing machine connection, incl. fittings,
19 St. Einzelraumlüfter,
ca. 85 m Wickelfalzrohr DN80-DN140
approx. 345 m heating pipe stainless steel with thermal insulation DN15-DN50,
19 pcs heating circuit distributor with distribution cabinet,
approx. 1400 m² underfloor surface heating installation system,