Disposable measures
Needle for cleaning the lacrimal ductsSingle, sterile;
with a curved end;
sizes G23 or G25, G27.
Stopper with injection socketSterile;
without latex, with a membrane;
yellow or other colors.
Protective paste stomaiSticky skin-protecting paste;
Packed in 60 ± 5 g.
Slack12.1. With a plastic buckle:
fabric, elastic;
with a plastic fixative;
disinfected (indicate the method of preparation).
12.2. Slinging with a metal buckle:
fabric, elastic;
with a metal latch;
disinfected (indicate the method of preparation).
Bush for difficult intubationPacked in 1 pc.;
length 66 ± 4 cm.
Suction kit 300 cmSterile;
Ch 25 - Ch 35 transparent flexible tube with a length of at least 3 meters;
At the end of the diameter of 6 to 8 mm, transparent handbag, with or without vacuum control.
High concentration oxygen mask for adultsFits snugly to the face, the edges are soft, not sharp;
the mask is fixed with the help of a rubber band, has a nose clip;
nedeformuota;
transparent tank of at least 1 liter;
oxygen tube not less than 2 m long, with an internal profile.
Manual resuscitation systemAdults;
reserve bag 1.5 l;
an uneven-walled oxygen tube of at least 2 m in length;
with a transparent oxygen mask, a soft head;
packed in 1 pc..
Respiratory filterElectrostatic principle of operation;
tightly packed in bags of 1 pc.;
the necessary 24-hour test protocols, which must include a standard description of the efficacy procedure, the micro-organisms on which the filters have been tested: MS-2 coliphage, Bacillus Subtilis, Mycobacterium Tuberculosis and Pseudomonas diminuta, Hepatitis C virus. (TDC TESTING IS UNSATISFACTORY);
the efficiency of the breathing filters for the 24th hour must be at least 99,99%;connections 22F/15M to 22M/15F, with a Luer opening:
the body of the breathing filters is made of polypropylene or equivalent material;without latex;volume 50-60 ml.
AbsorbentFrom a mixture of calcium and sodium hydroxide with hardening additives;
interacts with anesthetic gases - Sevofluran;
1 kg absorbs at least 110 l of CO2 ;
packed in 5 kg ± 0.50 kg;
clear discoloration.
Ultrasonic Gelsoluble in water;
Odorless;
hypoallergenic, not irritating the skin, pH 5.5-6.5;
viscosity 60000-95000 Mpa.s;
formaldehyde-free;
non-stick, easy to wipe;
high viscosity;
on the packaging there must be clear information about the series and shelf life;
soft packaging of 4-6 liters.
Percutaneous gastrostomy setSterile;
Ch 14, Ch 18 optionally according to hospital need;
The set consists of: a transparent gastrostomy (PEG) tube, with depth marks, with X-ray contrast marks, with a locking ring;
stopper;
puncture needle;
substance – pravedėjas.
Introduction with a branch for washing and a damperThe distal end is hardened and has the shape of a truncated cone;
Diameters from 4F to 9F, optionally according to hospital need;
Not less than 11 cm long;
Hemostatic valve;
Not shorter than 45 cm 0.035-0.038 inches of wire.
Dentalinė adata21.1. Dentalinė adata - 27 G
21.2. Dentalinė adata - 30 G
Kandikliai endoskopijomsOne-time;
With a wide, not narrower than 19 mm, central opening for the bite, and two holes at the edges;
With an elastic bracket over the head.
Biopsy tongs for colonoscopy, hotSterile;
length of the instrument 230-240 cm;
scoops oval without teeth or with teeth, optionally according to hospital need, scoops perforated, turning for the collection of a lateral biopsy, with or without a needle, optionally according to the Hospital's need;
suitable for work in the duct of an endoscope with a diameter of 2.8 mm.
Bioptic forceps for gastroscopySterile;
length of the instrument 155-165 cm;
scoops oval without teeth, scoops perforated, turning to take a lateral biopsy;
with or without a needle optionally according to hospital need;
suitable for work in the duct of an endoscope with a diameter of 2.8 mm
Biopsy tongs for enteroscopySterile;
length of the instrument 230-240 cm;
scoops oval without teeth, scoops perforated, larger turio;
turning to take a lateral biopsy;
suitable for work in the duct of an endoscope with a diameter of 2.8 mm.
Polypectomy loop, hotSterile;
Single;
ready for use;
working length not less than 230 cm;
suitable for work in the endoscope channel with a diameter of 2.8 mm;
loop – hexagonal shape;
widths of the unfolded loop 10 mm and 15 mm, optionally according to the hospital's need;
the loop is suitable for both the "hot" or "cold" way.
Polypectomy loop, coldsterile, lumpy;
ready for use;
working length not less than 230 cm;
suitable for work in the endoscope channel with a diameter of 2.8 mm;
loop – oval shape;
widths of the unfolded loop from 10 mm to 25 mm, at least 3 different, optionally according to the hospital's need.
Disposable injectors, for stopping bleeding, length 1600-1700 mmSterile;
Needle diameter 23 G or 25G, optionally according to hospital need;
Prick depth 4 mm, 5 mm or 6 mm, optionally according to the hospital's need;
Suitable for min. 2.8 mm endoscope channel.
Disposable injectors, for stopping bleeding, length 2300-2400 mmSterile;
Needle diameter 23 G or 25G, optionally according to hospital need;
Prick depth 3 mm or 4 mm, 5 mm or 6 mm, optionally according to hospital need;
Suitable for the 2.8 mm endoscope channel.
ECG paper for machine Kenz Cardico 112mm x 90mm x 280-320 sheets112mm x 90mm x 280-320 sheets
Additional distal tip of the endoscopeSterile, disposable, with additional "wings", with an internal diameter of 11.2 mm, placed at the distal endoscope, to work in the intestine to improve the visualization of the area under study;
Have a real Olympus endoscope available in the hospital.
Ligation loopSterile;
single use, ligation loop for polyps;
the loop is made of nylon, with a handle;
open loop diameter 35±5 mm;
working length 2300-2400 mm;
suitable for channel Ø 2.8 mm.
Electrodes for tonsillectomy, adenoidectomyThe Arthrocare ENT radiofrequency ablator Coblator II is appropriate;
flexible cobbling and coagulation electrode with two integrated channels for feeding and pumping saline, integrated cable;
working part with three electrodes arranged in parallel, creating a stable plasma field and removing tissue during tonsillectomy or adenoidectomy;
length of the working stem (flexible part) 137 ± 0.5 mm;
diameter 5,8 ±0,3 mm, suction hole crossbar 1,6 ±0,3 mm;
the reflux pole of the electrode is integrated on the axis of the electrode, it does not need to be oriented to come into contact with the tissues;there is no need for an electrode that grounds the patient.
Plastic connector for transfusing sterile liquidswith a filter of 0,45 ±0,05 μm and a cap;
resistant to lipids and alcohol products;
PVC-free, latex-free.
Thick sheeting glue, packed after 10 meterspacked after 10 meters.
Disposable bedding setsnon-woven fiber, white color;
disposable, non-sterile;
The set consists of:
sheet 140 x 240 ± 10 cm;
blanket cover 190 x 140 ± 10 cm;
pillowcase not less than 70 x 65 cm.
Massage oilWithout dyes, flavors and preservatives;
Does not irritate and does not allergenicize the skin;
Packaging 4500-5500 ml.
Semi-automatic biopsy needle for stuttering fabrics 18G x 20cm18Gx20 cm
Containers for medical wasteContainers for medical waste with a double lid.
The main lid has a second lid, which can be opened and closed several times, until the container is filled;
Plastic, yellow or red in color;
Bear a special hazardous waste label.
Talpa:
0.5 liter
1 liter
2-litre
3-litre
5-liter
12-litre
ECG paper in roll 80mmx30mRulonėlyje 80mmx30m
ECG paper for mac500 90mm x 90mm x 90mm x 350-380laps90mm x 90mm x 350-380 leaflets
Timpanogramos 110 mm rulonėlis110 mm
Thermal paper for ultrasonography, brightness quality HD, 110 mm x 20mbrightness quality in HD,
110 mm x 20 m
Silicone Foley catheters Ch8 – Ch26Sterile;
from medical silicone;
latex-free;
bichannels, with an astringent, rounded end, with a canister;
length 270-400 mm.
Frost packageOne-time;