Installation of elevators.
The installation locations of the elevator systems are taken into account as follows:
1. people/freight elevator PA0 1 building axles U-V/2-1,
2. passenger/freight elevator PA0 2 building axes G-H/3-4,
3. Passenger/freight elevator PA0 3 building axes S-T/3-1.
Drives: PA01 drive disc drives with gearbox separate engine room PA02 and PA03 as gearless drive disc drives, each arranged in the shaft head Number of stops:
— PA 01 5 stops,
— PA 02 5 stops,
— PA 03 10 stops with full load.
Elevator system PA01:
— load capacity: 3 300 kg/44 people,
— cabin depth: 3000 mm,
— cabin width: 2 100 mm,
— cabin height: 2 600 mm in L.,
— door dimensions: width 2 000 mm/height 2,500 mm
— Head: 17.68 m
Elevator systems PA02 and PA03:
— load capacity: 1,200 kg/15 people each,
— cabin depth: 2 100 mm each,
— cabin width: 1,200 mm each,
— cabin height: 2 200 mm i.l.
— door dimensions: each width 1 000 mm/height 2 100 mm,
— Head: 17.68 m each
Arrangement of the control cabinets:
— PA 01 in the UG in a separate engine room behind the shaft
— PA 02 at shaft access UG,
— PA 03 at shaft access UG.