Renovation, reconstruction and extension of the Otto Steiner School with curative day care center and sports hall - VE 430 ventilation.
New school building inventory HPT gym:
- Supply and exhaust air unit: 1 x with approx. 11,500 m
- 1 x with about 12 500 m
- Roof fans: 1 x about 2 000 m
- 1 x with about 1 500 m
Nb. School Stock HPT Gym:
- air duct, rectangular, L1, verz. Steel, up to 500 mm approx. 150 m
- air duct, rectangular, L2, verz. Steel, 500 mm to 1 000 mm approx. 850 m
- air duct, rectangular, L3, galvanized Steel, 1 000 mm to 1 500 mm approx. 200 m
- air duct, rectangular, L4, verz. Steel, 1 500 mm to 2 000 mm approx. 50 m
- Rectangular moldings, F1, verz. Steel, up to 500 mm approx. 100 m
- Rectangular shaped parts, F2, verz. Steel, 500 mm to 1 000 mm approx. 350 m
- Rectangular moldings, F1, verz. Steel, 1 000 mm to 1 500 mm approx. 40 m
- Rectangular moldings, F1, verz. Steel, 1 500 mm to 2 000 mm approx. 20 m
- Rectangular moldings, F1, verz. Steel, over 2,000 mm approx. 35 m
- Windelfalzrohr verz. Steel DN 80 - DN 160 approx. 550 m approx. 300 m approx. 125 m,
- Windelfalzrohr verz. Steel DN 180 - DN 250 approx. 190 m approx. 225 m approx. 70 m,
- Windelfalzrohr verz. Steel DN 300 - DN 500 approx. 140 m approx. 50 m,
- Refrigeration system as split unit with approx. 5.0 kW 1 St 1 St ..