The Institute for Fluid Dynamics operates high-pressure systems for the investigation of thermofluid-dynamic phenomena. A system for the investigation of supercritical CO
The CO
- Compact diffusion-welded plate heat exchanger with counterflow according to the Pressure Equipment Directive (2014/68 / EU),
- Operating point 1:
—— Side A: Medium: CO
—— Side B: Medium: CO
- Operating point 2:
—— Side A: Medium: CO
—— Side B: Medium: CO
- Operation of the recuperator up to 300 bar and 570
- Design pressure: -1 bar (g) (evacuation of the system; at the same time -10
- Design temperature: -10
- Delivery of the recuperator after acceptance of the entire device by an approved monitoring body (ZÜS), issue of a declaration of conformity for the entire system and evidence of the certificate of conformity,
- Design for at least a service life of 10,000 h and number of load cycles of 1,000
- Design, manufacture, testing and documentation in accordance with the Pressure Equipment Directive (2014/68 / EU), issuing of a CE mark required,
- Maximum pressure loss for all operating points and sides: 1.5 bar,
- Materials: pressure device and flange:
a) 2.4663 (NiCr23Co12Mo, Inconel 617) according to VdTÜV material sheet 485,
b) 1.4401 (X5CrNiMo17-12-2, 316),
c) 1.4404 (X2CrNiMo17-12-2, 316L).
The cooling water driven countercurrent CO
- Compact diffusion-welded plate heat exchanger with counterflow according to the Pressure Equipment Directive (2014/68 / EU),
- Operating point 1:
—— Side A: Medium: CO
—— Side B: Medium: water, mass flow: adjustable between 0.1 kg / s and 4.2 kg / s, inlet temperature: 35
Operating point 2:
—— Side A: Medium: CO
—— Side B: Medium: water, mass flow: adjustable between 0.1 kg / s and 4.2 kg / s, inlet temperature: 35
- Operation of the liquid cooler up to 300 bar and 260
- Design pressure: -1 bar (g) (evacuation of the system; at the same time -10
- Design temperature: -10
- Delivery of the liquid cooler after acceptance of the entire device by an approved monitoring body (ZÜS), issue of a declaration of conformity for the entire system and evidence of the certificate of conformity,
- Design for at least a service life of 10,000 h and number of load cycles of 1,000
- Design, manufacture, testing and documentation in accordance with the Pressure Equipment Directive (2014/68 / EU), issuing of a CE mark required,
- Maximum pressure loss for all operating points on the CO
- Materials: pressure device and flange:
a) 1.4401 (X5CrNiMo17-12-2, 316),
b) 1.4404 (X2CrNiMo17-12-2, 316L).
The offer price includes:
- Delivery according to DDP Dresden (Incoterms 2020),
- Acceptance of the recuperator by a central monitoring point and issuing of a CE mark before delivery,
- Acceptance of the liquid cooler by a central monitoring point and issuing of a CE mark before delivery,
- Complete documentation, documentation language German, including:
Operating and assembly instructions
Acceptance test certificates
Calculation of the heat exchanger surface with regard to the given thermal output and the operating points
- Guarantee of at least 24 months,
- Descriptive files and lists in MS Office, drawings in Auto-CAD,
- Issuance of a declaration of conformity for the entire system, evidence of the certificate of conformity and complete delivery including documentation within a maximum of 32 weeks after placing the order.