Fire fighting group vehicle LF 10 for the extinguishing group Ohle in accordance with DIN 14530-5, DIN EN 1846 Part 1-3, DIN 14502-2 in 3 lots.
Lot 1:: Chassis for a fire-fighting group vehicle based on DIN 14530-5, DIN EN 1846 1-3, DIN 14502- 2, Cat. 3, weight class M, according to DIN 1486-1
Lot 2.1: Firefighting equipment for a LF 10 incl. signalling, radio and communication equipment based on DIN 14530-5, DIN EN 1846 1-3, DIN 14502 -2
Lot 2.2: Firefighting loading for an LF 10 according to DIN 14530-5, DIN EN 1846 1-3, DIN 14502 Part 2
It may be offered by the tenderer only for lot 1 (chassis) or only for lots 2.1 and 2.2 (bodywork and loading) or for lots 1 and 2.1 and 2.2 (chassis and bodywork and loading).
Chassis for a fire-fighting group vehicle based on DIN 14530-5, DIN EN 1846 1-3, DIN 14502-2, Cat. 3, weight class M, according to DIN 1486-1Cab-over-engine chassis with all-wheel drive for the construction of a fire fighting group vehicle LF 10 according to EN 1846 / DIN 14502 and based on DIN 14530 Part 5 in the currently valid version. The standard equipment is supplemented by the application-specific special equipment. Weight class M.
If the minimum requirement with standard loading and additional loading is met, a mass reserve of 5% of the total mass must be available.
Further details can be found in LV 1
Fire brigade technical setup for a LF 10 incl. signalling, radio and communication equipment based on DIN 14530-5, DIN EN 1846 1-3, DIN 14502 -2Fire service structure:
The assessment within the scope of quality/functionality is carried out in particular according to the following evaluation criteria:
- Spatial conditions
- Ergonomics of the cockpit
- Entry and exit
-Comfort
- Internal and external security
- Quality chassis in general
- Quality of the general structure
- Quality of interior fittings, material
- Spatial conditions
- Accomodation of equipment/removal equipment
- Operability of additional equipment
The detailed information can be found in the document LV 2-1 Structure
Firefighting loading for an LF 10 according to DIN 14530-5, DIN EN 1846 1-3, DIN 14502 Part 2Firefighting loading for an LF 10 according to DIN 14530-5, DIN EN 1846 1-3, DIN 14502 Part 2
The detailed list can be found in the document LV 2-2 loading list.