Bridge-procedure, open and aggregated, divided into lots, to be awarded with the criterion of the most economically advantageous offer, for the supply of implantable pumps and neurostimulators, until 31/12/2023, and without prejudice to the option of repetition of the service for a further 12 months if, upon expiry, the ARIA agreements were not yet active.
- Rechargeable dual channel pulse generator for DBS directional stimulation / simultaneous multifrequency / system compatible with conditional MRI / constant current
- Directional lead 8 contacts 2 rings 2 directional active tip length about 45cm distance between contacts about 1.5mm
- Directional lead 8 contacts 2 rings 2 directional active tip length about 45cm distance between contacts about 0.5mm
- Patient charger remote control
- Extension for lead 8 contacts length about 55 cm
- Patient charging system
- Tunnelizer for extensions
- Implantable device for cranial fixing DBS leads
- OR Cable and 2x8 Extension
- Antenna for IPG programming
- Clinical programmer
- Keyboard for clinical programmer
- Power supply for clinical programmer
Rechargeable pulse generator for SCS spinal epidural stimulation with burst train current delivery- Rechargeable pulse generator for SCS spinal epidural stimulation with current burst train eroration
- charging system
- Medical programmer
- Patient control unit
Non-rechargeable pulse generator for burst train SCS spinal epidural stimulation- Non-rechargeable pulse generator for SCS pulse train spinal epidural stimulation
- Magnet for IPG
- Patient control unit
Rechargeable pulse generator system for SCS multi wave stimulation MRI total body conditioned compatible- Generatore di impulsi per SCS multi wave stimulation MRI total body conditioned compatibile
-Lead
- Anchoring system
- Kit for charging system
Pulse generator for deep brain stimulation, rechargeable in dual channel with constant current delivery for replacement on systems with fully elastic extensions- Rechargeable implantable pulse generator for deep brain stimulation (DBS) 2 channels 4+4 constant current supply for replacement - compatible with native implant with fully elastic extensions
- charging system
- Patient remote control
SCS/PNS stimulation system with subcutaneous device for wireless stimulation with accessories- Permanent PNS four-pole system with single four-pole fins
- Four-pole SCS/PNS system without permanent single fins
- Programmable antenna for trial phase
Rechargeable SCS System for Multimodal Differential Target Stimulation- Rechargeable pulse generator volume approx. 14 cm3
- Neurostimolatore sternum wireless
- Patient remote control
- Definitive system recharging system
PNS nerve implant system- Non-rechargeable four-pole pulse generator
- Quadripolar lead with flat terminal electrode distance about 3mm
- Four-pole lead with plate terminal electrode distance about 6mm
- Patient remote control
- Medical programmer
Non-rechargeable, single-channel deep brain stimulation pulse generator with constant current or constant voltage delivery and accessories- Single channel pulse generator for non-rechargeable dbs
- Adapter for 1x4 extension connection
- Adapter for 2x4 extension connection
Rechargeable dual channel deep brain stimulation system with constant current delivery and constant voltage RM compatible (conditioned) and accessories- Dual channel pulse generator for DBS rechargeable with DC/VC
- Implantable device for cranial fixing DBS leads
- Rechargeable pulse generator charging system
- Patient programmer
- Four-pole electrode length about 40 cm neutral tip about 1mm 4 contacts spaced about 0.5mm
- Tunnelizer for extensions
- Quardipole electrode length about 40 cm neutral tip about 1mm 4 contacts spaced about 1.5mm
- Extension cable for four-pole electrode length about 60cm
- Clinical programmer
- Extension cable for four-pole electrode length about 95cm
Dual channel non-rechargeable deep brain stimulation pulse generator with constant current or constant voltage delivery and accessories- Dual channel pulse generator for non-rechargeable DBS
- Medical programmer with VTA optimization system interface
- Patient programmer
Non-rechargeable deep brain stimulation system with directional electrodes and accessories- Two-channel non-rechargeable pulse generator
- Patient control unit
- Medical programmer
- Cranial fixing system electrodes
- DBS directional leads 8 contacts 2 directional rings 2 neutral tip length about 40cm distance between contacts of about 0.5mm
- Flexible extensions length about 60cm with tunneling kit
- DBS directional leads 8 contacts 2 directional rings 2 neutral tip length about 40cm distance between contacts of about 1.5mm
- Cranial fixing system electrodes
- DBS directional leads for dx 8 contacts 2 directional rings neutral tip length about 40cm distance between contacts of about 0.5mm
- DBS directional leads with marker for dx 8 contacts 2 directional rings neutral tip length about 40cm distance between contacts of about 0.5mm
- DBS directional leads for left 8 contacts 2 directional rings 2 neutral tip length about 40cm distance between contacts of about 1.5mm
- DBS directional leads with marker for left 8 contacts 2 directional rings neutral tip length about 40cm distance between contacts of about 1.5mm
- Extension tunneler
- Cranial tunnelizer
- Cable for intraoperative macrostimulation
- Extension length about 60cm
- Extension length about 60cm with marker
- Extension length about 95cm
- Extension length about 95cm with marker
- Non-rechargeable pulse generator with software for real-time brain signal processing and analysis
- Patient remote control
SCS spinal stimulation system, 16-pole non-rechargeable (MRI compatible) and accessories- Pulse generator for SCS 16 poles non-rechargeable RMN conditioned compatible
- Compact octopolar lead length about 75 cm
- Flat lead 16 contacts
- Patient programmer
- Medical programmer
Programmable Implantable Pump with peristaltic action for intrathecal infusion of drugs and accessories MRI conditioned compatible- Programmable implantable pump with peristaltic action 20ml tank
- Programmable implantable pump with peristaltic action s 40ml tank
- Catheter tunnellizator - length approx. 38cm
- 4-layer intrathecal catheter length 66cm
- Medical programmer
Implantable and programmable system for the treatment of refractory epilepsy with vagus nerve stimulation and accessories- Pulse generator with heart rate detection and automatic HR related stimulation
- Helical electrode for vagus nerve measures 0.2mm
- Patient kit with magnet
- Subcutaneous tunnelizer