Lot 7.1 - Drywall construction - Walls and ceilings
Drywall
150 m² single stud walls with and without insulation, various wall thicknesses, double-layer planking on both sides GKB/ GKBI
40 m² single stud walls without insulation, planking on both sides two-layer aqua panel
105 m² double/installation stud walls with insulation, various wall thicknesses, double-layer planking on both sides GKB/ GKBI
42 m² double/installation stud walls without insulation, various wall thicknesses, planking on one side two-layer Aquapanel, one-sided two-layer GKB/ GKBI
100 m² double/installation stud walls without insulation, rear not planked, planking on one side two-layer GKB/ GKBI
85 m² single stud walls without insulation, as floor-to-ceiling facing shell, planking on one side in two layers Aqua panel
130 m² single stud walls without insulation, as floor-to-ceiling facing shell, planking on one side in two layers GKBI
6 m² single stud walls without insulation, as floor-to-ceiling cladding, F90
23 m² opening closure installations free-span
33 pcs inspection openings in plasterboard walls
750 m reinforcement profiles for fixtures
60 pcs installation bushings for electrical, HLS in various sizes
Drywall ceilings with ceiling fixtures and extensions
370 m² acoustic slab ceiling with mineral wool overlay, offset round perforation, with edge frieze made of smooth GK panels
780 m² GK slab ceiling, planking 1 x GKB
300 m² GK slab ceiling, planking 1 x GKBI
115 m² GK slab ceiling, planking 1 x aqua panel
117 m² GK slab ceiling F90, planking 2x 20 mm solid construction panels
1150 m wall connection with shadow gap
210 m wall connection without shadow gap
240 m Free ceiling end/ ceiling sail
95 m² GK ceiling aprons, planking GKB/ GKBI/ solid construction board (F90)
87 pcs inspection openings in plasterboard ceilings
8 inspection openings F90 in plasterboard ceilings