1. The subject of the order is the delivery of test apparatus with technical parameters in accordance with the specification indicated in the OPZ - Annex No 1 to the SWZ.
2. Individual packages correspond to separate parts of the order.
3. A factory new apparatus is required, free from physical and legal defects, having the relevant certificates, complying with all applicable legal standards.
4. The test apparatus shall have the warranty period indicated separately for individual packages calculated from the date of signing the receipt protocol.
5. The Contractor will provide warranty service for the provided apparatus.
6. Warranty service will be provided with the Ordering Party. In case of impossibility of on-site repairs with the Contracting Authority during the warranty period, the costs of ship/transport shall be borne by the Contractor.
7. The Contractor, together with the apparatus, will provide instructions for use in Polish and warranty card.
Package no. 1 - Gas chromatographs set - 1 kplPackage No 1 — Gas Chromatographs Set — 1 kpl
1) Set of 3 gas chromatographs with equipment
General requirements and the required minimum parameters and parameters of the additionally scored set are indicated in OPZ - Annex No 1 to SWZ.
2) Required warranty period for the entire set: 24 months.
3) The Contractor shall provide, contribute and mount the apparatus to the Ordering Party at his own expense. Insurance and transport of the apparatus to the place of delivery of the Ordering Party will be carried out at the expense and risk of the Contractor. The Contractor shall provide such packaging of the object of the order in order to prevent its damage or deterioration during transport.
4) The Contractor will launch the apparatus and give instruction to the employees of the Ordering Party.
Package No. 10 — Shoulder — 1 pcs.Package No. 10 — Shoulder — 1 pcs.
1) Description:
Minimum technical requirements:
• Maximum load — at least 50 g
• Minimum reading accuracy — 0.1 mg
• Addiction — Automatic
• Color Touch Capacitive Display
• Interface — at least the following interfaces: USB (at least version 2.0), Ethernet, Wi-Fi.
• Power supply in the range of at least 220 ÷ 240 V.
• Operating temperature in the range of not less than 10 — 40 °C.
• Heating element — infrared heater.
• Repeatability of humidity not less than +/ -0.05% (sample ~ 2g), +/ -0.01% (sample ~ 10g).
• Minimum humidity reading accuracy — 0.0001%.
• Drying temperature range at least up to 160 °C
• At least 4 drying profiles.
• Identification of the sample.
2) Delivery date: up to 30 days from the date of conclusion of the contract.
3) Place of delivery: Skierniewice, 15/17 Rybicki Street.
4) Required warranty period: 24 months.
5) The Contractor shall provide, contribute and mount the apparatus to the Ordering Party at his own expense. Insurance and transport of the apparatus to the place of delivery of the Ordering Party will be carried out at the expense and risk of the Contractor. The Contractor shall provide such packaging of the object of the order in order to prevent its damage or deterioration during transport.
Package no. 11 — Analyzer of oxygen (O2) and carbon dioxide (CO2) concentrations in MAP-type packs — 1 pcs.Package no. 11 — Analyzer of oxygen (O2) and carbon dioxide (CO2) concentrations in MAP-type packs — 1 pcs.
An analyzer of oxygen (O2) and carbon dioxide (CO2) concentrations in MAP packs with a small intake of gas for analysis (not more than 10 ml) and a wide measuring range.
Specific requirements are set out in Annex 1 to SWZ - Description of the object of the order.
Required warranty period: 12 months.
The Contractor shall provide, contribute and mount the apparatus to the Ordering Party at his own expense. Insurance and transport of the apparatus to the place of delivery of the Ordering Party will be carried out at the expense and risk of the Contractor. The Contractor shall provide such packaging of the object of the order in order to prevent its damage or deterioration during transport.
The Contractor will launch the apparatus and give instruction to the employees of the Ordering Party.
Package No. 12 — Laboratory, Automatic System of Controlled Atmospheres (KA) — 1 kpl.Package No. 12 — Laboratory, Automatic System of Controlled Atmospheres (KA) — 1 kpl.
1) Description:
Laboratory automatic controlled atmospheres system (KA) designed to operate 100 experimental containers (90 existing experimental, stationary containers KA and 10 new ones to be delivered) with integrated high-purity nitrogen generator and PLC and PC control systems and 10 new independent containers, including equipment, for storage in RQ technology consisting of:
• System for handling 90 test channels of experimental containers KA (with a capacity of 0.4 m3 to 0.5 m3 and 0.8 m3 to 1 m3), consisting of three modules of 32 channels for containment testing using the following technologies: NA, MA, KA, ULO, ILOS Plus and DKA (in cooperation with technology-dedicated sensors — not on system equipment).
• Portable oxygen and carbon dioxide concentration analyzer, for controlling measurement of gas concentrations (O2 and CO2) directly from the experimental containers KA
• High-purity nitrogen generator from atmospheric air
• Central control unit (e.g. PC)
• System 10 containers for storage in RQ technology
• Ethernet modules for local and remote connectivity to the parent PC, providing the ability to preview, change parameters (s), archive and display measurement data (graphs)
• Essential connection and installation materials of the system
Specific requirements are set out in Annex 1 to SWZ - Description of the object of the order.
Required warranty period: 12 months.
The Contractor will provide, and bring the apparatus to the Ordering Party at his own expense. Insurance and transport of the apparatus to the place of delivery of the Ordering Party will be carried out at the expense and risk of the Contractor. The Contractor shall provide such packaging of the object of the order in order to prevent its damage or deterioration during transport.
The Contractor shall launch the apparatus and give instruction to the employees of the Ordering Party within a separate date indicated by the Ordering Party, but not later than 6 months from the date of delivery.
Package No. 2 - System for ozonation - 1 pcPackage 2 — System for ozonation — 1 pcs.
Laboratory air-containment and water ozonation system for obtaining the following ozone concentrations:
• in air/storage atmosphere up to 100 ppm (in experimental containers with a capacity of 50 to 1000 liters)
• in air/storage atmosphere up to 20 ppm (in a chamber with a volume of up to 20m3)
• distilled water with a temperature of about 0°C to 15 ppm (stainless steel bath with a total capacity of about 0.9 m3 — dimensions length 190 cm x width 85 cm x depth 55 cm)
Specific requirements are indicated in OPZ - Annex No 1 to SWZ.
Required warranty period: 24 months.
The Contractor shall provide, contribute and mount the apparatus to the Ordering Party at his own expense. Insurance and transport of the apparatus to the place of delivery of the Ordering Party will be carried out at the expense and risk of the Contractor. The Contractor shall provide such packaging of the object of the order in order to prevent its damage or deterioration during transport.
The Contractor will launch the apparatus and give instruction to the employees of the Ordering Party.
Package no. 3 - Computer Tomograph with hardware and technical facilities - 1 kpl.Package no. 3 — Computer Tomograph with hardware and technical facilities — 1 kpl.
High-energy stationary computer microtomography system with equipment and technical facilities
Specific requirements are indicated in OPZ - Annex No 1 to SWZ.
Required warranty period: 12 months.
The Contractor shall provide, contribute and mount the apparatus to the Ordering Party at his own expense. Insurance and transport of the apparatus to the place of delivery of the Ordering Party will be carried out at the expense and risk of the Contractor. The Contractor shall provide such packaging of the object of the order in order to prevent its damage or deterioration during transport.
The Contractor will launch the apparatus and give instruction to the employees of the Ordering Party.
Package No. 4 - Chromatographic set - 1 pc1) Description:
Two-channel gas chromatograph with FID, TCD and MS detectors, factory new, allowing for analysis of O2, CO2, HCN, volatile saturated and unsaturated hydrocarbons (in particular the possibility of separation of ethane, ethylene and acetylene) on FID and TCD detectors, as well as analysis of substances Volatile using MS type detector using backflush technology.
Configuration:
dual-channel gas chromatograph with fast cooling furnace (GC)
automatic liquid sample feeder (AS)
Automatic Hypersurface Phase Analysis (HS)
Programmable dispensers for capillary columns of PTV type
MS type detector
heat-conductivity detector (TCD) and flame-ionization detector (FID) connected in series.
System configuration allowing the use of backflush technique and the ability to analyze the sample on an MS detector or on connected TCD-FID detectors regardless of the method of specimen (headspace or automatic liquid sample feeder).
Minimum parameters and specific requirements are contained in OPZ - Annex 1 to SWZ.
Required warranty period: 24 months.
The Contractor shall provide, contribute and mount the apparatus to the Ordering Party at his own expense. Insurance and transport of the apparatus to the place of delivery of the Ordering Party will be carried out at the expense and risk of the Contractor. The Contractor shall provide such packaging of the object of the order in order to prevent its damage or deterioration during transport.
Package No. 5 - Incubator with cooling — 12 pcsPackage No. 5 — Cooling Incubator — 12 pcs.
1) Description:
Minimum technical requirements:
• Vertical (cabinet) construction
• Capacity min. 100 liters
• Maximum external dimensions:
width 850 mm
depth 650 mm (excluding protruding external elements mounted on the door, e.g. handle, display)
• Minimum internal dimensions:
width 550 mm
depth 350 mm
• Stainless steel shelves with suspension height adjustment (minimum 3 pcs.)
• Interior made of stainless steel
• Forced air circulation
• PID controller-controlled heat.
• Temperature setting range at least from -10°C to +60°C
• Microprocessor controller, operating parameters displayed on the liquid crystal display.
• Spatial homogeneity of temperature at a set of +35°C not worse than 0,5°C.
• The ability to construct programs containing at least up to 12 temperature changes over time. Programs repeated at least 1 to 99 times or in an infinite loop.
• Built-in memory for a minimum of 10 programs.
• Working in 24-hour real time clock or independent timer mode
• Work parameter registration function with the ability to preview history from a period of at least 10 weeks back.
• Possibility to set the device on the countertop or to set the devices on top of each other.
• Capability to retrofit the interface for communication with the PC
• Equipment with a dedicated optional lamp set providing light with a minimum intensity of 3000lx.
• Automatic diagnostics system with fault identification.
• Power supply 220V-240V.
• Device new in factory configuration according to manufacturer's specifications, not undergoing alterations and modifications.
2) Required warranty period: 24 months.
3) The Contractor shall provide, contribute and mount the apparatus to the Ordering Party at his own expense. Insurance and transport of the apparatus to the place of delivery of the Ordering Party will be carried out at the expense and risk of the Contractor. The Contractor shall provide such packaging of the object of the order in order to prevent its damage or deterioration during transport.
The additionally scored requirements are included in Annex 1 to SWZ - Description of the item of the order.
Package no. 6 - Analytical Weight - 1 pcPackage no. 6 - Analytical Weight - 1 pc
1) Description:
Minimum technical requirements:
• Maximum load — not less than 50 g
• Minimum load — not more than 1 mg
• Minimum reading accuracy of 0.01 mg
• Addiction — internal (automatic)
• Color Touch Capacitive Display
• Databases — at least 7
• Interface — at least USB, Wi-Fi, Ethernet
• Power supply in the range of not less than 220 ÷ 240 V
• Operating temperature in the range of not less than 10 — 40 °C
2) Required warranty period: 24 months.
3) The Contractor shall provide, contribute and mount the apparatus to the Ordering Party at his own expense. Insurance and transport of the apparatus to the place of delivery of the Ordering Party will be carried out at the expense and risk of the Contractor. The Contractor shall provide such packaging of the object of the order in order to prevent its damage or deterioration during transport.
Package No. 7 — Lab Weight — 1 pcsPackage No. 7 — Lab Weight — 1 pcs
1) Description:
Minimum technical requirements:
• Maximum load — at least 310 g
• Minimum load — not more than 10 mg
• Read-Accuracy — 0.1 mg
• Addiction — Automatic
• Color Touch Capacitive Display
• Databases — not less than 7
• Interface — at least the following interfaces: USB (at least version 2.0), Wi-Fi, Ethernet
• Power supply in the range of not less than 220 ÷ 240 V.
• Operating temperature in the range of not less than 10 — 40 °C.
2) Required warranty period: 24 months.
3) The Contractor shall provide, contribute and mount the apparatus to the Ordering Party at his own expense. Insurance and transport of the apparatus to the place of delivery of the Ordering Party will be carried out at the expense and risk of the Contractor. The Contractor shall provide such packaging of the object of the order in order to prevent its damage or deterioration during transport.
Package No 8 — Precision Weight — 1 pcsPackage No 8 — Precision Weight — 1 pcs
1) Description:
Minimum technical requirements:
• Maximum load — not less than 4.5 kg
• Read-Accuracy — 0.001 g
• Addiction — Automatic
• Color Touch Capacitive Display
• Databases — not less than 7
• Interface — at least the following interfaces: USB (at least version 2.0), Ethernet, Wi-Fi.
• Power supply in the range of not less than 220 ÷ 240 V AC 50/60 Hz
• Operating temperature — not less than 10 - 40 °C
2) Required warranty period: 24 months.
3) The Contractor shall provide, contribute and mount the apparatus to the Ordering Party at his own expense. Insurance and transport of the apparatus to the place of delivery of the Ordering Party will be carried out at the expense and risk of the Contractor. The Contractor shall provide such packaging of the object of the order in order to prevent its damage or deterioration during transport.
Package No. 9 — Conduccometer — 1 pcsPackage No. 9 — Conduccometer — 1 pcs
1) Description:
Minimum technical requirements:
• Resistance range of at least 0.001 µS/cm to 1 S/cm, and 3 salinity scales
• EC calibration at least at 4 points and at 1 salinity point
• Registration:
- continuous, automatic registration of measurements or on request,
- automatic record of a minimum of 100 series with at least 50000 records,
- the possibility of carrying out at least 200 reports,
• USB port (at least version 2.0) for data transfers to your PC.
2) Required warranty period: 24 months.
3) The Contractor shall provide, contribute and mount the apparatus to the Ordering Party at his own expense. Insurance and transport of the apparatus to the place of delivery of the Ordering Party will be carried out at the expense and risk of the Contractor. The Contractor shall provide such packaging of the object of the order in order to prevent its damage or deterioration during transport.