New extension Lichtigfeldschule, Westendstr. 45 + 47, 60325 Frankfurt am Main
18 classrooms, 1 cafeteria, underground, ground floor to 5 floor, floor area approx. 5,000 m
Drywall work according to DIN 18340
Manufacture of underlays, facing shells, fire protection clothing, partitions and similar constructions as space-forming components of the construction in dry construction.
Walls:
- Non-load-bearing internal partitions DIN 4103-1, substructure made of galvanized sheet steel profiles DIN EN 14195 and DIN 18182-1, as a single and double column, partly in fire wall construction, partly with requirements for sound insulation and / or fire resistance, gypsum wall cladding, fire protection boards, Cement boards and in combined construction,
- Attachment shells, substructure made of galvanized sheet steel profiles DIN EN 14195 and DIN 18182-1, as a single stand, cladding made of plasterboard
- Shaft walls DIN 4103-1, substructure made of galvanized sheet steel profiles DIN EN 14195 and DIN 18182-1, as a single stand, partly with requirements for sound insulation and / or fire resistance, cladding made of plasterboard and cement building boards,
- Connections, connections, corners, free wall ends, soffits, openings, backs of niches, T-joints, replacements and reinforcements of new constructions, connecting and adapting drywall, reinforcements of openings, trusses. Drywall profiles, Diffusion-inhibiting / -tight layers including connections.
Cover:
- suspended ceilings DIN 18168-1, interior, gypsum plasterboard, substructure made of galvanized sheet steel profiles DIN EN 14195 and DIN 18182-1,
- suspended ceilings DIN 18168-1, inside, linings made of plaster cassettes DIN 18180 and DIN EN 520, substructure made of galvanized sheet steel profiles DIN EN 14195 and DIN 18182-1,
- suspended ceilings DIN EN 13964, cladding as a cassette made of sheet steel, substructure made of galvanized sheet steel profiles,
- suspended ceilings DIN EN 13964, coverings made of mineral wool cover plates, substructure made of galvanized sheet steel profiles,
- Insulation in the ceiling cavity, substructure of galvanized sheet steel profiles DIN EN 14195 and DIN 181821-1, cladding made of plasterboard,
- Connections, Detachable clothing parts, free ceiling ends, friezes, height gaps, roof window soffits, openings, replacements and reinforcements of substructures, access hatches, drywall profiles, diffusion-inhibiting / -tight layers including connections
Protective membranes:
- Shaft walls DIN 4103-1, substructure made of galvanized sheet steel profiles DIN EN 114195 and DIN 18182-1, as a single stand, with requirements for sound insulation and fire resistance, linings made of fire protection boards,
- Shaft walls DIN 4103-1, substructure made of galvanized sheet steel profiles DIN EN 14195 and DIN 18182-1, as a single stand, with requirements for fire resistance, planking made of calcium silicate boards,
- Airline clothing with fire resistance requirements, calcium silicate board clothing,
- fire-protection clothing on girders and columns, with fire resistance requirements, with gypsum panels with fleece reinforcement,
- connections, corners, openings, T-connections.