Repair and maintenance services of medical and surgical equipment

Contract Value:
-
Notice Type:
Contract Notice
Published Date:
20 September 2023
Closing Date:
23 October 2023
Location(s):
PL613 Bydgosko-Toruński (PL Poland/POLSKA)
Description:
Inspections and repairs of medical equipment

Inspections and repairs of medical equipment

System reviews for non-invasive diagnostics of the circulatory and autonomic systems

According to SWZ records and price form

Spare parts for review:

- Pompa ContBP 12V

- Pompa OscBP 6V

- Elektrozawór OscBP

Inspections:

- Regulacja ECG, ICG, OscBP, ContBP

- Kalibracja ECG, ICG, OscBP, ContBP

-Disinfection

- Electrical safety tests

- Leak tests

Inspections of GDX-70/C2H4O measuring heads (with replacement equipment)

According to SWZ records and price form

- Dismantling the head

- Installation of a replacement head

- Calibration in the measurement laboratory

- Dismantling the replacement head

- Head assembly

Replacement equipment included in the price of the inspection

Inspections of the cryo-surgery apparatus CRYO-S ELECTRIC II and the cryosurgery apparatus CRYO-S CALSSIC

According to SWZ records and price form

- General assessment of the condition of the camera

- Cleaning the device

- Functionality tests

- Replacement of O-rings and leak check

- Verification of measuring instruments of the device

- Electrical safety tests

X-ray diagnostic monitor reviews

According to SWZ records and price form

- External control of the device

- Safety measurement with the right meter

- Replacement of bactericidal radiator

- Cleaning and maintenance

- Measurement of functional parameters

- Monitor calibration

Inspections of the VNG device, the ENTHERMO 304T water caloric simulator and the SMART EP ARRS OAE auditory evoked potentials test device

According to SWZ records and price form

Annual review including:

- Checking the technical condition

- Validation of work

- kalibrację

Electrocardiograph reviews ascard green v.06.101

According to SWZ records and price form

Annual review, which includes:

- Electrical safety test in accordance with IEC 60601-1 (meeting the safety standard PN EN 62353) carried out with a dedicated Rigel 288 tester.

- Control the condition of the case, the operation of the keyboard, printer and fastening of elements.

- Functional test carried out with the Rigel Uni-Pulse 400 tester (ECG simulator) and a test confirming the correct operation of all functions in accordance with the technical documentation.

Electrocardiograph reviews LUMED EUROECG with trolley

According to SWZ records and price form

Technical Inspection

-Maintenance

- Electrical safety tests

- Checking the operation of the camera for WTO compliance 25/2020

- Necessary instruments:

* Electrical safety tester RIGEL 277

* RIGIEL 33 Simulator

* BRYMEN digital meter

Surgical laser reviews VELAS PRO-30B15D

According to SWZ records and price form

- Electrical safety check

- Checking the level of laser radiation emission

Inspections of the NWM monitoring apparatus and diagnosis of breathing disorders during sleep

According to SWZ records and price form

Annual review, which includes:

- Visual inspection, checking the serial numbers of components.

- Verification of sensors / all system components / verification of correct operation of channels (impedance)

- Checking the video path

- Software update/replacement

- Consumable check, condition and expiration date

- Performing a test test.

A-SCAN PACSCAN 300 Ophthalmic Ultrasound Reviews - BIOMETER

According to SWZ records and price form

- Electrical safety tests

- Function test

- Visual assessment

- Checking the correctness of operation

FISH System Overview

According to SWZ records and price form

Annual review, which includes:

- cleaning of optical surfaces (lenses, glasses, spectacle cap, condenser, glass plate - at field aperture, available filters, polarizing elements)

- cleaning of mechanical surfaces (table tripod, handle of preparations, caps),

- Koehler lighting setting,

- setting polarizing filters,

- checking the correctness of the electrical system,

- regulation of the video path,

- checking the centering mechanism in the universal condenser,

control and possible lubrication of table guides.

Reviews of GENERAL MIDITECH transport cardiac monitors

According to SWZ records and price form

- Technical review

- Technical maintenance \measurements and functional tests

- Tests and calibration

- Electrical safety test

- Control of operating parameters

Inspections of the VIVID IQ ultrasound echocardiography machine

According to SWZ records and price form

- Camera maintenance

- Calibration of transducers

-Electrical safety tests according to IEC 606001-1

Przeglądy diatermii AUTOCON III 400

According to SWZ records and price form

-Cleaning

- Power measurement

- Functional tests

- Electrical safety tests

Inspections of the MESOTEST II nyctometer

According to SWZ records and price form

- Odkurzenie

- Washing optics

- Checking the correctness of operation

- Check connections

- Software update (if newer version is available)

- Camera calibration

- Electrical safety test according to 62353

Reviews of the device for controlled hypothermia CRITICOOL

According to SWZ records and price form

- Visual inspection

- Functional tests

- Control of operating parameters

- Filter replacement

Inspections of washer-disinfector type PWD 82545 SAD

According to SWZ records and price form

- Leak check

* Water inflow/outflow

* Dosing system

* Pressure booster pump

* Door, door gasket

- Visual inspection and operation

* Washing arm: pan/bolt function control

* Basket insert: control of correct locking

* Inspection of washing nozzles

* Tank: float switch control, cleaning if necessary

* Water drainage check

* Door lock control

* Rollover protection

- Dosing system control

* Check dispensing systems, including emptying message

* Optical dosing control in tank and/or boiler

* Dosing calibration

- Dosing/calibration of process chemicals

* Stone binder

*Detergents

- Security checks

* Thermoelectric measurement

* Security control

- Parameter changes

Przeglądy kardiomonitorów Cardio 9000 STANDARD

According to SWZ records and price form

- full control of the safety of the cardiac monitor,

- full control of cardiac monitor operating parameters,

- visual inspection of the cardiac monitor:

* assessment of the visual condition,

* assessment of the condition of the wires,

* assessment of the earthing condition,

* assessment of the condition of equipment,

- cleaning the cardiac monitor and internal components of the device from dust and dirt,

- service calibrations if calibration is necessary:

* Capnography sensor

* NIBP module

- functional tests,

- service tests (if the software provides for the possibility of performing tests or the software is not blocked),

- control of operating parameters using control and measurement equipment (ECG, SpO2, NIBP, TEMP, IBP, CO2, CO, ICG),

- electrical safety test,

- Reset the alert regarding the required inspection and programmatically set the date of the next review

Inspections of the NEOPROBE 2300 NPCU23 gamma radiation detector and SCM23 mammotome

According to SWZ records and price form

Replacement equipment for the time of inspection included in the price of the inspection

Detector:

- Checking accessories

- Cleaning the unit

- Functional test

- Electrical safety test

- Test according to instruction number 00-0298

Mammotom:

- Cleaning the unit

- Functional test

- Electrical safety test

- Checking accessories

Inspections of the THOPAZ digital chest drainage system

According to SWZ records and price form

- Control and visual verification of the device

* Verification of the external condition of the device - checking the occurrence of: cracks, mechanical damage, discoloration on the housing and manometer

* Inspection of the presence of technical socket covers (power supply and data ramping)

* Checking the correct operation of the mounting brackets

* Readability of the nameplate

* Control of the efficiency of the canister release button

* Checking the presence of canister gasket

* Device cleanliness rating

* Efficiency of the docking station and power supply

- Device tests

* Making an FPT test with a measuring pressure gauge

* Conducting a functional test

* Checking the correct operation of battery power

* Checking the acoustic signal (alarms)

* Battery charging test

- Spare parts available

* Dren

*Can

* Uszczelka

- Electrical safety test standard 62353

Przeglądy kabiny z promiennikami emitującymi UVB/UVA WALDMANN UV 7002

According to SWZ records and price form

Annual review, which includes:

- Checking and calibrating the intensity of UVA and UVB radiation emitted by the cabin,

- Performing a functional test

- Taking possible measures to eliminate the problem (without the use of spare parts)

- Electrical safety test

- Every 24 months replacement of air filters in the UV7002 cabin - 1 time during the term of the contract

Przeglądy kardiotokogramu BTL FC

According to SWZ records and price form

- Checking the technical condition

- Electrical safety tests

Inspections: ABATOR 50AE, AERATOR XL, EO gas sterilizer with equipment and 5XL gas sterilizer

According to SWZ records and price form

Sterylizator:

- Review every 6 months

- Dismantling of compressed air filters, replacement of 0.3 micron and 0.1 micron filter with O-rings

- Checking the ventilation line

* Check for tightness of connections between the sterilizer and the installation in the hospital

* Check for bends and other blockages that may interfere with proper air circulation

* Checking if the installation is done according to the specification

Humidification system

- Replacement of the stem and O-rings of the humidification valve; if necessary, replacement of the solenoid valve

Vacuum system

- Cleaning the air solenoid valve stem. Replacement if necessary

- Replacement of air reducer components using a repair kit

- Vacuum pump cleaning

- Door locking system

* Cleaning the door closing solenoid valve. Cleaning the stem and socket; replacement if necessary

* Control of the door lock mechanism

- Vent system

* Disassembly of the breather solenoid valve. Cleaning the stem and socket; replacement if necessary.

* Replacement of the bacterial filter

- Dismantling of the punch solenoid valve. Replacement of mandrel and O-rings.

- Cleaning of the water system

* Dismantling of the water tank

* Rinse with clean water

* Checking the PVC pipe connecting the tank with the solenoid valve for cracking; if necessary, replacement with a silicone tube of the same diameter

Abattoir:

- Abator filter replacement

- Air flow measurement (fan check)

- Catalyst temperature check

Aerator:

- Replacement of the bacterial filter - 2 pcs.

Autoefractometer inspections with non-contact tonometer function TONOREF II NIDEK

According to SWZ records and price form

AUTOREFRACTOMETER WITH NON-CONTACT TONOREF II NIDEK FUNCTION

- external visual inspection;

- control of the nameplate;

- housing wear assessment;

- tightening the screws fixing the housing;

- control of the operation of buttons;

- power outlet control;

- electrical safety test according to PN:EN 62 353

- control on work using an artificial eye

Inspections of ultrasonic knife PIEZOMED SA-320

According to SWZ records and price form

A review once every 3 years, which includes:

- Check for errors in the device's memory.

- Verification of all functions.

- Verification of the correctness of the piezoelectric transducer.

- Software upgrade (if available).

- Check the condition of the water pump rollers.

- Maintenance of connections on the electronics board.

Harmonic knife inspections GEN11 (with replacement equipment)

According to SWZ records and price form

-Disinfection

- Visual inspection

- Functional test

- Software update

- Output verification

- Electrical safety test

- Quality assurance test

Replacement equipment for the time of inspection included in the price of the inspection

Przeglądy kriokomory ALASKA AL01

According to SWZ records and price form

- Checking the condition of the outer and inner cryochamber plating

- Checking the condition of glass and seals

- Checking the condition of the door: the treatment chamber and the entrance to the vestibule 1 and 2

- Checking the condition of floor panels

- Checking the tightness of the power supply system

- Checking the patency of the power supply system and the condition of the nozzles

- Checking the chamber supply system with cryogenic liquid

- Checking the cryochamber drying system

- Control system check

- Control software check

- Checking the condition of lighting: external cryochamber, treatment chamber, atria

- Checking the status of door lock sensors

- Checking the light condition of the visualization of the location of the doors of the vestibules 1 and 2 and the treatment chamber

- Checking temperature sensors

- Checking the functioning of the controller

- Checking the functioning of the T1 and T2 temperature measurement system in the treatment chamber

- Check of the emergency shutdown system (safety)

- Checking the condition of the panel with filters for dust removal from ice dust cryochamber

- Checking the condition of the blinds between the accumulation chamber and the treatment chamber

- Check the status of the emergency exit panel

- Checking the functioning of the voice communication system with the patient

Inspections of syringe infusion pumps SP-12 SPRO-N

According to SWZ records and price form

- Checking the correctness of operation

- Technical maintenance

- Measurements and functional tests

- Tests and calibrations

- Electrical safety test

Inspections of the OCULIGHT GL IRIDEX Ophthalmic Laser

According to SWZ records and price form

- Checking the laser beam power with a dedicated meter

- Electrical safety test in accordance with PN-EN 62353

Skull trepan repairs

According to SWZ records and price form

1 - skull trepan GB304R 12/15 mm with HUDSON tip - GB 304 R - 051097

2 - TREPAN SKULL - GB 304 R - 049393

3 - TREPAN SKULL TE563 - GB 304 R - 062168

4 - skull trepan GB304R 12/15 mm with HUDSON tip - GB 304 R - 51098

5 - skull trepan GB304R 12/15 mm with HUDSON tip - GB 304 R - 51101

6 - trepan skull GB304R 12/15 mm with HUDSON tip - GB 304 R - 051077

7 - Skull bone perforator - GB 304 R - 047982

8 - skull trepan GB304R 12/15 mm with HUDSON GB 304 R 051076 tip

9 - trepan skull - GB 304 R - 049198

10 - skull trepan GB304R 12/15 mm with HUDSON tip - GB 304 R - 051085

11 - TREPAN SKULL - GB 304 R - 051520

12 - TREPAN SKULL - GB 304 R - 049703

13 - TREPAN SKULL - GB 304 R - 048201

14 - TREPAN SKULL - TE 563 - 063650

15 - TREPAN SKULL TE563 - TE 563 - 062168

16 - TREPAN SKULL TE563 - TE 563 - 063668

17 - TREPAN SKULL - TE 563 - 063679

18 - TREPAN SKULL - TE 563 - 063674

19 - trepan skull - TE563 - TE 563 - 062968

20 - trepan of the skull - TE 563 - 050361

21 - Trepan skull TE563 - TE 563 - 062242

22 - TREPAN SKULL - TE 563 - 050480

23 - TREPAN SKULL - TE 563 - 062669

24 - trepan skull GB304R, TE563 12/15MMTE - TE 563 - 050368

25 - trepan skull GB 300R - TE 563 - 036808

26 - skull trepan GB302R 9/12 mm with HUDSON tip - TE 561 - 063082

27 - skull trepan GB302R 9/12 mm with HUDSON tip - GB 302 R - 063124

28 - skull trepan GB302R 9/12 mm with HUDSON tip - GB 302 R - 063121

29 -Trepan skull GB302R - GB 302 R - 060671

30 - skull trepan GB302R 9/12 mm with HUDSON tip - GB 302 R - 063115

31 - TREPAN SKULL - GB 302 R - 062283

32 - skull trepan GB302R 9/12 mm with HUDSON tip - GB 302 R - 063118

33 - TREPAN SKULL - GB 302 R - 0644150

34 - TREPAN SKULL - GB 302 R - 062272

35 - trepan skull GB302R 9/12 mm with HUDSON tip - GB 302 R - 063084

36 - Climb 9x12 - GB 302 R - 064681

37 - skull trepan GB302R 9/12 mm with HUDSON tip - GB 302 R - 63099

38 - skull trepan GB302R 9/12 mm with HUDSON tip - GB 302 R - 63114

39 - TREPAN SKULL - GB 302 R - 053561

40 - Trepan skull TE562 - TE 562 - 062210

41 - TREPAN SKULL - TE 562 - 062807

42 - trepan skull GB302R - TE 562 - 063019

43 - trepan skull GB302R - TE 562 - 061615

44 - TREPAN SKULL - TE 562 - 061693

45 - TREPAN SKULL - TE 562 - 064513

CLEMENT-CLARK Synoptophore 2001 and CANON RK-F1 autorefractometer

According to SWZ records and price form

- external visual inspection;

- control of the nameplate;

- housing wear assessment;

- tightening the screws fixing the housing;

- control of the operation of buttons;

- power outlet control;

- electrical safety test according to PN:EN 62 353

- in the case of autorefractometer, there will be an additional check on the work using an artificial eye;

Inspections of BTL 4625 SMART electrotherapy devices

According to SWZ records and price form

-Electrical safety tests

- Checking the correctness of operation

Reviews of BRAINLAB neuronavigation systems

According to SWZ records and price form

- Visual and mechanical inspection of all system hardware components and instruments (if available) according to Brainlab inspection protocols

- Comprehensive maintenance of the computer unit (replacement of filters, cleaning of the hard disk, installation of the latest security patches, etc.)

- Electrical safety test

- Verification of third-party integration (e.g. C-arms, microscopes, etc.)

In addition, with neuronavigation - 2021:

- Checking the accuracy of the optical tracking device (Vega camera)

Inspections of the apparatus for magnetic isolation of genetic material Maxwell RSC 48

According to SWZ records and price form

Annual review of the Maxwell RSC 48 including:

- Full system control,

* Cleaning and inspection of all components,

* External enclosure cleaning and inspection

* Cleaning and inspection of the device platform and internal surfaces

- Control of adjustment and adjustment of the device

- Software update

Technical inspections of Bechtold ELTRON 80 surgical diathermy and Bechtold ELTRON 80 surgical diathermy with ELTRON SE smoke suction with trolley

According to SWZ records and price form

- Security and functionality tests

- Measuring equipment necessary to perform the inspection - CHIROTEST Measuring Tester

Inspections of RADICAL7 capnometers with ROOT with ISA/Nomoline MASIMO module

According to SWZ records and price form

-Check

- Kalibracja

- Electrical safety test

Download full details as .pdf
The Buyer:
10 Wojskowy Szpital Kliniczny z Polikliniką Samodzielny Publiczny Zakład Opieki Zdrowotnej
CPV Code(s):
50420000 - Repair and maintenance services of medical and surgical equipment