For a detailed description of the item of the order, see Annex 2 to SWZ “Price Form”
PART I“Universal set reinforced
Minimum composition and dimensions:
1) Servet with adhesive tape 175x175cm, layered construction, additional absorbent reinforcement in the critical zone, in the napkin integrated conductor organizers — 1pcs.
2) Service with adhesive tape 240x150cm, layered construction, additional absorbent reinforcement in the critical zone, in the napkin integrated conductor organizers — 1pcs.
3) Servets with adhesive tape 75x75cm, layered construction, additional absorbent reinforcement in the critical zone — 2pcs.
4) Table coverlet 150x190cm, absorbent layer 75x190cm — 1pcs.
5) Adhesive tape impermeable elastic 9x49cm - 1pc
6) Absorbent towels 18x25cm — 4pcs
7) Mayo table cover 79x145cm, absorbent layer 65x85cm - 1pcs
Material requirements:
Items 1,2,3, made of three-layer min. laminate with a weight of > 79 g/m2 having additional reinforcement (fourth layer) in the non-woven critical zone of 50g/m2, total weight in the critical zone 129 g/m2, resistance to liquid penetration (hydrostatic pressure) throughout the entire surface of the napkins min. 100cm H2O, one of the layers was PE film, dry/wet push strength (critical zone) > 280/160 kPa, the napkins meet the requirements of PN EN 13795-3 High quality,
Packaging paper-foil bag or foil with label in Polish with at least two stickers to be pasted in medical records as no. The product sterilized according to the standards required by law.
Quantity in pack 12 pcs” pcs 83
Part of the 10thVelcro self-adhesive tape with a size of 5x15cm of 2 pcs. Quantity in pack 240 pcs. "pcs 250
Medical tape self-adhesive fixing, barren 50x9 cm, single packaged pcs 500
Adhesive pocket used during dislocation of the hip joint with a size of 75x120cm. Quantity in pack 84 pcs. "pcs 60
Part 100Compress non-woven sterile 4-layer weight 40 g\ m2 packed 5 pcs. 5 cm x 5 cm op 2000
7.5 cm x 7.5 cm op 2000
10 cm x 10 cm op 2000
Compress non-woven sterile 4-layer weight 40 g\ m2 packed 10 pcs. 5 cm x 5 cm op 2000
7.5cm x 7.5cm op 3000
10 cm x 10 cm op 3000
Part 101Straps for no traumatic wound closure, self-adhesive straps so called external seams made of reinforced nylon non-woven fabric, covered with acrylic glue, air permeability enables gas exchange between strap and leather, easy and fast application, hypoallergenic packaged 3 pcs. 75 mm x 6 mm op 300
38 mm x 6 mm op 200
Part 102Surgical tape, dressing made of hydrophobic non-woven with microperforations allowing gas exchange between the skin and the external environment. The tape has a silicone paper rear protection with a metric pitch for precise splitting with scissors. Packaging: carton -dispenser. After the lid is torn off, it is possible to eject the tape without removing it from the carton. Picture instructions for use on the package. Non-alloy tape. 5 cm x 10 m op 20
10 cm x 10 m op 20
15 cm x 10 m op 100
20 cm x 10 m op 100
25 cm x 10 m op 20
30 cm x 10 m op 20
Part 103Dressing with absorbent cartridge, self-adhesive, made of hydrophobic non-woven, covered with hypoallergenic acrylic adhesive, micropores in non-woven structure provide adequate vapor permeability, centrally placed absorbent cartridge coated with polyethylene mesh, rounded edges, has Silicone paper safety layer, hypoallergenic, barren. (6 cm x 15 cm) 50 pcs
(6 cm x 10 cm) 50 pcs op 30
(5 cm x 7.2 cm) of 100 pcs op 10
(10 cm x 30 cm) 25 pcs op 20
(10 cm x 25 cm) of 25 pcs op 100
(10 cm x 20 cm) 25 pcs op 80
(10 cm x 15 cm) 30 pcs op 50
(10 cm x 10 cm) 30 pcs op 80
An islet dressing, surgical, self-adhesive, made of hydrophobic non-woven with microperforations for gas exchange between the skin and the external environment, having an absorbent cartridge of viscose and polyester coated with a polyethylene mesh to prevent adhesion to the wound. Dressing with cut and hole O, for protecting drains. The dressing has a rear security made of silicone paper. Paper packaging, on each package picture instructions for use of dressing. 9 cm x 10 cm.x 30pcs op 50
"
12cm x 14cm.x 25pcs” op 20
Part 104Bone wax made of 70% beeswax and 30% petroleum jelly reduces bone bleeding by closing bone vessels, double depleted and double-packed. Packaging 20 envelopes x 2.5 g. op 1
Part 105Non-woven patch with dressing, self-adhesive made of hydrophobic non-woven in absorbent cartridge, white color, has microperforation for proper air permeability, good air and water vapor permeability, has a protective layer of silicone paper facilitating painless and effective application, hypoallergenic, non-alloy. X 1pcs 6cm x 1m pcs 100
8 cm x 1 m pcs. 200
Non-woven, elastic coated with acrylic glue, has a two-stage application system to facilitate precise, painless and effective adhesive, flesh-colored, self-adhesive, hypoallergenic, non-alloy. (5.9 cm x 6.2 cm) 50 pcs.
(7 cm x 7.1 cm) 50 pcs. 1
Stabilizing pint for the intubation tube - the set consists of 2 washers and a fastening strap. The pads are fixed to the patient's cheeks with an adhesive part, having on the other side a layer of Velcro, washers and strap covered with hypoallergenic glue, non-alum. Set consists of 2 washers and 1 strap. set 1
Stabilizing for drains - a two-piece stabilizer composed of a fastening part to the skin and a part fastening of the drain, the possibility of repositioning and correcting the position of the drain due to the use of Velcro, covered with hypoallergenic glue. Size 9 cm x 3 cm Barren x 50 pcs 2
Size 9 cm x 3 cm Non-sterile. x 50 pcs. 2
Surgical, hypoallergenic, cotton fabric, with serrated edges, facilitating splitting without the use of scissors across and along, with waterproof acrylic adhesive evenly applied over the entire surface with high adhesion, without latex, rubber and zinc oxide, large tearing strength and high adhesion, including oily skin, easy to mark with a pen on the surface. X 1 2.5 cm x 9.14 m pcs 10
5cm x 9.14m pcs 30
Surgical, hypoallergenic, made of transparent polyethylene film, with macro-perforation on the entire surface, allowing splitting without scissors along and across, elastic, with waterproof acrylic adhesive evenly applied over the entire surface, without latex, rubber and oxide zinc 12sz=1op 2.5 cm x 9.14 m op 10
Part 106Non woven gauze soaked in 70% isopropyl alcohol with good sanitizing properties and a wide spectrum of bactericidal and fungicidal effects, packed 100 pcs. 3 cm x 6.5 cm op 1
Part 107Warm-cold compress made of strong, non-toxic film, included with non-woven cover, Compress can be washed, disinfected, cooled or heated, hypoallergenic, non-alloy. X1pcs Size 12 x 29 cm. pcs 10
Size 13 x 14 cm pcs. 10
Size 16 x 26 cm pcs. 10
Size 21 x 38 cm pcs. 4
Size 30 x 40 cm pcs. 2
Part 108Sterile, disposable blanket for burns and large wounds. It is a barrier against bacteria and promotes the healing and granulation process of the wound. Non-adhesive aluminum layer (for burn/wound) and outer soft layer of viscose non-woven fabric. It allows exudates and blood to penetrate without sticking to the wound surface, which reduces the risk of infection. Hypoallergenic, has high breathable properties, high fluid absorption capacity (>750%). Blanket weight 225 g/m2. Product sterilized with ethylene oxide. Packing foil/paper or paper/paper. Medical device class IIa pursuant to Medical Devices Directive 93/42/EEC Size 75 cm x 250 cm pcs 50
Part 109Sterile polyurethane dressing for fixing central catheters with two small cutouts. Size 10 x 12 cm with wide applicators (min. 2.5 cm), laminated tag and wide laminated non-woven strap with a notch. Ponacinane transversely edged reinforced from the underside with a non-woven on each side. Quick application in 2 steps (security paper and frame). Acrylic glue applied to the mesh (film) in a way that guarantees high vapor permeability. Resistant to alcohol-containing disinfectants. Packing of foil type. 10 cm x 12 cm pcs 500
Bactericidal adhesive polyurethane dressing for fixing central catheters with excision and with hydrogel containing 2% chlorhexidine gluconate. Instant bactericidal effect after application. Size 8.5 x 11.5 cm with wide applicators (min. 2.5 cm), price tag and 2 non-woven strips. The edging reinforced from the underside with a non-woven on each side. Quick application in 2 steps (security paper and frame). Acrylic adhesive applied in a way that guarantees high vapor permeability. Resistant to alcohol-containing disinfectants. Paper film wrapping 8.5 cm x 11.5 cm pcs 100
Sterile polyurethane dressing for fixing peripheral cannulas with a notch. Size 6 x 7 cm with frame and tag. Resistant to alcohol-containing disinfectants. Acrylic glue applied evenly. Packing of foil type. 6 cm x 7 cm pcs 3 000
Sterile polyurethane dressing for fixing peripheral cannulas in children with a notch. Size 5 x 5.7 cm with wide applicator (min. 3 cm). Colorful app for kids. Strengthening with non-woven. Resistant to alcohol-containing disinfectants. Acrylic glue applied evenly. Packing of foil type. Packaging: 100 pcs 5 cm x 5.7 cm pack 84
Barren blade for securing perimeter inserts for mounting cannul, self-adhesive made of hydrophobic non-woven, covered with hypoallergenic acrylic adhesive, has a protective layer of silicone paper to facilitate precise painless and effective application, measuring 7.6 x 5,1 cm 7.6 cm x 5.1 cm pcs 50,000
Surgical, hypoallergenic, of microporous non-woven polyester without viscose and cellulose content, with macro-perforation over the entire surface, allowing scissor-free split along and across, with acrylic adhesive evenly applied over the entire surface, without the content of oxide zinc, rubber and latex, waterproof, high adhesion at the time of application and long time. 2.50 cm x 9.14 m pcs 4,000
5.0cm x 9.14pcs 100
Surgical, hypoallergenic, microporous non-woven, with waterproof evenly applied to the entire surface with acrylic glue, without latex, rubber and zinc oxide, extremely delicate for the skin. 7.50 cm x 9.14 m pcs 40
5.00 cm x 9.14 m pcs 40
2.50cm x 9.14m pcs 2,000
Surgical, hypoallergenic, elastic foam (PVC), with waterproof acrylic adhesive, evenly applied over the entire surface, without latex, rubber and zinc oxide, stretchable along and across, allowing compression dressings and on moving parts of the body. 00 cm x 5.00 m pcs 20
7.50 cm x 5.00 m roll 10
Part of the 11th"
Sterile surgical napkin in size 75x90cm made of three-layer laminate (two layers of non-woven with a total weight of 43g/m2 and PE film 40μ), with adhesive tape along the longer side. High resistance to fluid penetration min. 900cm H2O. On the unit packaging shall be the manufacturer's information, REF No, series No, expiry date. Double packaging system in cardboard boxes. The material must comply with the requirements of EN 13795, confirm by the technical card of the finished sterile product. Quantity in pack 168 pcs” pcs 120
Buttock cartridge 75x100 cm barren, single packaged 100
Part 110Diapers for adults with problems of incontinence and feces in medium and severe degrees, having a breathable laminate on the entire surface - size XS (minimum absorbency 1400g), retention according to. NAFC min. 390g, frills along the absorbent cartridge facing outward, four elastic adhesives for multiple attachment, 2 waist pulls (front and back), double humidity indicator: black print blurring under the influence of liquid, adhesive - 2 yellow stripes, changing colour to green under the influence of liquid, belt circumference 40 - 60cm). Two anatomically shaped absorbent cartridges of cellulose pulp with superabsorbent. Minimum sizes: total length of diaper 640mm, width 420mm. Weight 1 pcs diaper min. 53g. Packaging A'10, op 10
Diapers for adults with a breathable laminate on the entire surface - size S (minimum absorbency 1600g), retention according to. NAFC min. 480g, frills along the absorbent cartridge facing outwards, preventing urine and feces outflow, four flexible adhesive corpses for multiple attachment, 2 waist pulls (front and back), double humidity indicator: black blurring imprint under the influence of liquid, adhesive - 2 yellow stripes, changing the color to green under the influence of liquid, belt circumference 55 - 80cm). Two anatomically shaped absorbent cartridges of cellulose pulp with superabsorbent. Minimum sizes: total length of diaper 720mm, width 520mm. Weight 1 piece of diaper min 67g. Packaging A'30. op 50
Diapers for adults with problems of incontinence and feces of medium and severe degrees, having a breathable laminate on the entire surface - size M (minimum absorbency 2300g), retention according to. NAFC min. 640g, frills along the absorbent cartridge facing outwards, preventing urine and feces outflow, four elastic adhesives for repeated attachment, 2 waist pulls double humidity indicator: black print blurring under the influence of liquid, adhesive - 2 yellow stripes, changing color to green under the influence of liquid, belt circumference 75 - 110cm). Two anatomically shaped absorbent pulp absorbent cartridges with superabsorbent. Packaging A'30. op 200
Diapers for adults with problems of incontinence and feces of medium and severe degrees, having a breathable laminate on the entire surface - size L (minimum absorbency 2600g), retention according to. NAFC min. 690g, frills along the absorbent cartridge facing outwards, preventing urine and feces outflow, four flexible adhesive corpses for multiple attachment, 2 waist pullers (front and back), double humidity index: black imprint blurring under the influence of liquid, adhesive - 2 yellow stripes, changing the color to green under the influence of liquid, belt circumference 100 - 150cm). Two anatomically shaped absorbent cartridges from pulp with superabsorbent Minimum Sizes: total diaper length 970mm, width 790mm. Weight 1 piece of diaper min 107g. .Packaging A'30. op 1500
Diapers for adults with problems of incontinence and feces of medium and severe degrees, having a breathable laminate on the entire surface - size XL (minimum absorbency 2600g), retention according to. NAFC min. 690g, frills along the absorbent cartridge facing outward, preventing urine and feces outflow, four flexible Velcro adhesive for multiple attachment, 2 waist pullers (front and back), double humidity indicator: black print blurring under the influence of liquid, adhesive - 2 yellow stripes, changing the color to green under the influence of liquid, belt circumference 130 - 170cm). Two anatomically shaped absorbent pulp absorbent absorbent. Minimum sizes: total diaper length 970mm, width 860mm. weight of 1 piece diaper not less than 109g. Upper absorbent cartridge length 490mm, lower 820mm, absorbent cartridge width: front 280mm, center 160mm, rear 280mm. Weight 1 piece of diaper min 109g. ON
Part 111Hygiene primer for use as additional protection. The underside layer is a white non-slip insulating film with a print. In the absorbent cartridge there is shredded cellulose, additionally covered with tissue paper. The top layer is non-woven. Total size 90x60cm, primer weight min. 42.5g, absorbency not less than 940g according to ISO 11948-1.
Hygiene primer for use as additional protection. The underside layer is a white non-slip insulating film with a print. In the absorbent cartridge there is shredded cellulose, additionally covered with tissue paper. The top layer is non-woven. Total size 40x60cm, primer weight min. 48g, absorbency not less than 847g according to ISO 11948-1.
Hygiene primer for use as additional protection. The underside layer is a white non-slip insulating film with a print. In the absorbent cartridge there is shredded cellulose, additionally covered with tissue paper. The top layer is non-woven. Total size 60x60cm, weight of primer min. 65g, absorbency not less than 1395g according to ISO 11948-1.
Hygiene primer for use as additional protection. The underside layer is a white non-slip insulating film with a print. In the absorbent cartridge there is shredded cellulose, additionally covered with tissue paper. The top layer is non-woven. Total size 90x60cm, weight of primer min. 95g, absorbency not less than 2000g according to ISO 11948-1.
Hygiene primer with special non-woven wings to roll under the mattress, for use as additional protection. The underside layer is a white non-slip insulating film with a print. In the absorbent cartridge there is shredded cellulose, additionally covered with tissue paper. The top layer is non-woven. Total size of the primer 90x170cm, cartridge size min. 82cm x 58cm, primer weight min. 109g, absorbency not less than 2000g according to ISO 11948-1.
Barren hygiene primer for use as an additional protection. The underside layer is a white non-slip insulating film with a print. In the absorbent cartridge there is shredded cellulose, additionally covered with tissue paper. The top layer is non-woven. Size 60x60cm, primer weight min. 64.5g, absorbency not less than 1400g according to ISO 11948-1. Paper and foil bag type. The packaging contains a large, legible bipartite, triple-perforated barcode label with two TAG type labels, containing: index, series number, LOT, for keeping medical records. After the TAGs are peeled off, the main label remains on part of the package. Required document in the form of a report validation of the sterilization process.1 op a 1pc op 50
Non-allium napkins made of non-woven compress 40g, pack A'50 pieces, white, size 80x60cm. op 45
"
Tissue and film roll primers, width 33cm, perforation every 50cm for easy peeling off, roll length 25m (50 pieces on roll), blue color, cellulosic and polyethylene laminate, weight min. 40g/m2, including hygiene paper min. 24 g/m2, thickness of polyethylenene film 16 μm, glue layer 3 g/m2, water barrier min. 700cm H20, longitudinal tear strength min. 20 N/5cm, transverse 10N/5cm.
“op 300
Primers on paper and film roll, width 51cm, perforation every 80cm for easy peeling off, roll length 40m (50 pieces of primers on roll), blue color, cellulosic and polyethylene laminate, weight min. 40g/m2, including hygiene paper min. 24 g/m2, thickness of polyethylene film enowa 16μm, glue layer 3 g/m2, water barrier min. 700cm H20, longitudinal tear strength min. 20 N/5cm, transverse 10N/5cm. op 975
Part 112Bib and foil bibs, size 51x65cm on roll, number 30 pieces, blue color, cellulosic and polyethylene laminate, weight min. 40g/m2, including hygiene paper min. 24 g/m2, thickness of polyethylene film 16μm, glue layer 3 g/m2, water barrier min. 700cm H20, rip-off strength longitudinal min. 20 N/5cm, transverse 10N/5cm. op 50
“Care wipes soaked, ph 5.5 - 3 in 1, moisturizing, refreshing and cleansing. Size of single handkerchief min. 25x30cm, pack A'52. Without the content of parabens, alcohol and fragrance compositions.
“op 200
Part 113Absorbent panties (closed system), designed for people with medium to severe urinary incontinence. Laminate breathable all over the surface. Absorbent cartridge made of cellulose pulp with superabsorbent. A special layer distributing urine. Side casings along the absorbent cartridge and frills with elastic yarn in the inguinal area. Humidity indicator as an ink print, blurring under the influence of contact with liquid. Panties equipped with a special tapeworm for wrapping the worn product, placed in the back part. Size S belt circumference 55-85cm),. Packaging A'10. op 4
Absorbent panties (closed system), designed for people with medium to severe urinary incontinence. Laminate breathable all over the surface. Absorbent cartridge made of cellulose pulp with superabsorbent. A special layer distributing urine. Side casings along the absorbent cartridge and frills with elastic yarn in the inguinal area. Humidity indicator as an ink print, blurring under the influence of contact with liquid. Panties equipped with a special tapeworm for wrapping the worn product, placed in the back part. Size M belt circumference 80-110cm), Packaging A'10. op 33
Part 114Diapers for adults having a breathable laminate on the entire surface - size XXL (minimum absorbency 3200g), retention according to. NAFC min. 1140g, frills along the cartridge facing outward, absorbent to prevent the outflow of urine and feces, four elastic 3-layer fasteners: adhesive Velcro for multiple attachment, 2 waist pullers (front and back), double humidity indicator: black print blurring under Effects of liquid, adhesive - 2 yellow stripes, changing the color to green under the influence of liquid, belt circumference (160 - 210cm). Two anatomically shaped absorbent absorbent cartridges from pulp with superabsorbent. Minimum sizes: total length of diaper 1015mm, width 640mm-1620 mm (front back with belt). Weight 1 piece of diaper 153g. Packaging A'10. op 30
Part 115Diapers for adults having a breathable laminate on the entire surface - size XXL (minimum absorbency 3200g), retention according to. NAFC min. 1140g, frills along the cartridge facing outward, absorbent to prevent the outflow of urine and feces, four elastic 3-layer fasteners: adhesive Velcro for multiple attachment, 2 waist pullers (front and back), double humidity indicator: black print blurring under Effects of liquid, adhesive - 2 yellow stripes, changing the color to green under the influence of liquid, belt circumference (160 - 210cm). Two anatomically shaped absorbent absorbent cartridges from pulp with superabsorbent. Minimum sizes: total length of diaper 1015mm, width 640mm-1620 mm (front back with belt). Weight 1 piece of diaper 153g. Packaging A'10. op 30
Part 116Gypsum band, quick-moving up to 5 min, roll made of eco-friendly cardboard or wound on a perforated pin made of plastic 3 m x 10 cm pcs 3 000
3m x 12cm pcs 3,000
3 m x 14 cm pieces 6,000
Padding band for plaster dressings made of synthetic cotton wool 3 m x 6 cm pcs. 100
3 m x 10 cm pc 1 000
3 m x 12 cm pc 1 000
3 m x 15 cm pcs 1 000
3 m x 20 cm 800 pcs.
3 m x 25 cm pcs 800
Part 117Gypsum band, quick-moving up to 5 min, roll made of eco-friendly cardboard 3 m x 10 cm pcs. 2 100
3m x 12cm pcs 3,000
3 m x 14 cm pcs.
Padding band for plaster dressings made of synthetic cotton wool 3 m x 6 cm pcs. 50
3 m x 10 cm pcs 700
3 m x 12 cm pc 1 000
3 m x 15 cm pcs 2,500
3 m x 20 cm pc 1 000
3 m x 25 cm pcs 800
Part 118Box with box for description x 50 packs 50
Part 119Operating servets, of gauze min. 17 to threadbare, 4 layer with radiation thread and tapeworm, package A'1. Packaged in a paper-foil bag with special welding along the shorter side with an obtuse V-shape - the so-called chevron, which further facilitates dust-free opening of the package, in the bag there are cut cuts for the thumb to capture the film with your thumb for easier opening. packaging.Paper and foil bag with large readable double-perforated label with 2 TAGs on the package (information on tags: expiration date, index, LOT number, barcode). After the 2 tags are peeled off, the main label remains on the part of the package. Dressing material yarn min. 15 TEX, type of sterilization: steam. Required validation report of the sterilization process. Dressing Material Class 2a Rule 7. 45 cm x 45 cm Op. 900
Operating servets, of gauze min. 17-to threadbare, 4 layer with radiation thread and tapeworm. Packaged 5 pcs. Packaged in a paper-foil bag with special welding along the shorter side with an obtuse V-shape - the so-called chevron, which further facilitates dust-free opening of the package, in the bag there are cut cuts for the thumb to capture the film with your thumb for easier opening. packaging.Paper and foil bag with large readable double-perforated label with 2 TAGs on the package (information on tags: expiration date, index, LOT number, barcode). After the 2 tags are peeled off, the main label remains on the part of the package. Dressing material yarn min. 15 TEX, type of sterilization: steam. Required validation report of the sterilization process. Dressing material class 2a rule 7. 45 cm x 45 cm, op. 1 200
Operating servets, of gauze min. 17-to threadbare, 8 layer with radiation thread and tapeworm. Packaged 5 pcs. Packaged in a paper-foil bag with special welding along the shorter side with an obtuse V-shape - the so-called chevron, which further facilitates dust-free opening of the package, in the bag there are cut cuts for the thumb to capture the film with your thumb for easier opening. packaging.Paper and foil bag with large readable double-perforated label with 2 TAGs on the package (information on tags: expiration date, index, LOT number, barcode). After the 2 tags are peeled off, the main label remains on the part of the package. Dressing material yarn min. 15 TEX, type of sterilization: steam. Required validation report of the sterilization process. Dressing Material Class 2a Rule 7. 45 cm x 45 cm Op. 800
Non-allium operating servets, of gauze min. 17-to threadbare, 4 layers with radiation thread and tapeworm .Packed 10pcs Yarn min. 15 TEX. Class 2a, Rule 7. Designed for sterilization min water vapor 45 cm x 45 cm Op. 10
Non-elastic operating servets, of gauze min. 17-to threadbare, 8 layers with radiation thread and 25pc tapeworms. Yarn min. 15 TEX. Class 2a, rule 7. Designed for sterilization min water vapor. 45 cm x 45 cm, op. 5
Operating servets, of gauze min. 17-to threadbare, 4 layer with radiation thread and tapeworm. Packaged 5 pcs. Packaged in a paper-foil bag with special welding along the shorter side with an obtuse V-shape - the so-called chevron, which further facilitates dust-free opening of the package, in the bag there are cut cuts for the thumb to capture the film with your thumb for easier opening. packaging.Paper and foil bag with large readable double-perforated label with 2 TAGs on the package (information on tags: expiration date, index, LOT number, barcode). After the 2 tags are peeled off, the main label remains on the part of the package. Dressing material yarn min. 15 TEX, type of sterilization: steam. Required validation report of the sterilization process. Dressing material class 2a rule 7. 75 cm x 90 cm, op. 150
Operating services,17 thread.16 layer with X-ray contour and 30cmx30cm tapeworm, set a'2 pcs Service unsewn on the sides, giving
Part of the 12th"
Sterile three-layer surgical napkin in size 150x175cm made of two non-woven layers with a total weight of 43g/m2 and PE film thickness 40μ. Fluid penetration resistance min. 900cm H2O. On the unit packaging shall be the manufacturer's information, REF No, series No, expiry date. Double packaging system in cardboard boxes. The material must comply with the requirements of EN 13795, confirm by the technical card of the finished sterile product. Quantity in package 36 pcs
“pcs 150
Part 120Colored surgical marker, made by knitting technique from multifilament polyester yarns in the form of strands with side tailors wrapped inward. Made of 100% polyester. Expiration date min 5 years. Barren product. Bag type unit packaging Foil paper with lashings label in one color. Extracts in 4 colors to choose from: red, blue, yellow, white. Extract length 900 mm and 3 types of width: 2mm, 3mm, 4mm. Tear strength: 2mm/900mm-9daN, 3mm/900mm-15daN, 4mm/900mm-20daN. Packaging A'10 pcs., Op. 10
Caesarean section set, barren, comprising: Gas servet with X-ray contrast and 30 cm x 30 cm tapeworm, 17 threads,16 layers (4 pcs), Service unsewn on the sides, unsewn, Gas compresses 17 threads 12 layers with contrast RTG 10 cm x 10 cm. 10 pcs (40 pcs .). Weight 1 piece of compress min. 3 g, size of cut min. 31 x 39 cm. Cotton ribbon with canvas weave length 260 cm, width 1 cm (1 pc). Set packaged in 2 paper-foil bags with large readable double perforated label with 2 TAGs on the outer packaging (tag information: expiration date, index, LOT number). After the 2 tags are peeled off, the main label remains on the package. Dressing material yarn min. 15 TEX, type of sterilization: steam. Medical device registered in Class IIa Rule 7. Op. 500
Part 121Tupspheres (tampons) barren gauze ball min. 17-to thread, with radiation thread packed 10 pcs. Packaged in a paper-foil bag with special welding along the shorter side with an obtuse V-shape - the so-called chevron, which further facilitates dust-free opening of the package, in the bag there are cut cuts for the thumb to capture the film with your thumb for easier opening. packaging.Paper and foil bag with large readable double-perforated label with 2 TAGs on the package (information on tags: expiration date, index, LOT number, barcode). After the 2 tags are peeled off, the main label remains on the part of the package. Dressing material yarn min. 15 TEX, type of sterilization: steam. Required validation report of the sterilization process. Dressing material class 2a rule 7. 9.5 cm x 9.5 cm according to p. Zaof Beans Op. 10
15 cm x 15 cm, Op. 500
20 cm x 20 cm, Op. 600
Gas sterile setons with X-ray thread 17N 4W. Packaged 1 pcs. Packaged in a paper-foil bag with special welding along the shorter side with an obtuse V-shape - the so-called chevron, which further facilitates dust-free opening of the package, in the bag there are cut cuts for the thumb to capture the film with your thumb for easier opening. packaging.Paper and foil bag with large readable double-perforated label with 2 TAGs on the package (information on tags: expiration date, index, LOT number, barcode). After the 2 tags are peeled off, the main label remains on the part of the package. Dressing material yarn min. 15 TEX, type of sterilization: steam. Required validation report of the sterilization process. Dressing Material Class 2a Rule 7. 2 m x 5 cm Op. 250
2 m x 7.5 cm Op. 150
2 m x 10 cm Op. 150
Part 122Washing foam for use instead of water and soap, gently cleanses the skin, leaving a protective layer, effectively moisturizes. 500 ml — in composition: olive oil, lactic acid, D-Panthenol. op. 300
Concentrated three-polymer cream with silicone to protect the skin from fluids and incontinent/faeces, provides moisturizing of dry and chapped skin, without zinc oxide and alcohol content, 24 hours (application every 3-4 episode of incontinent/fecal incontinence), effectiveness skin protection is clinically confirmed on a group of 200 patients (attach a list of publications of clinical trials). Tubka 92 g. pcs 50
Protective cream with zinc oxide to prevent the formation of inflammation, vaporization and pressure ulcers. 200 ml, Op. 200 ml
Sterile non-alcoholic three-polymer formulation with silicone for the protection of healthy and damaged skin, the addition of plasticizer provides a non-cracking barrier on the skin. Protective effect for 72 hours, the effectiveness of protecting the skin from damage by ur/feces clinically confirmed at the minimum group 900 patients (attach a list of publications of clinical trials). Flakon with atomizer 28 ml. (140 sprays) pcs 25
Part 123Shampoo in foam for washing hair without using water. For all types of hair. It cleanses and gives the hair softness without loading them. The shampoo is intended to contain a nourishing and irritation-soothing linen bioplex and a fragrance scientralizer. Recommended when washing hair with water use is hindered, including after procedures within the head or bedridden. Active ingredients: DeoPlex or equivalent, linseed biocomplex. Packaging Foam Pump Bottle with 200ml. Op10
Part 124Gelatin sponge with hemostatic effect, made of pork or fish gelatin, completely absorbable, absorbs on average 50 times its mass, hemostasis time 2-4 minutes, the time after which it is completely absorbed 3-4 weeks.x 1 7 cm x 5 cm x 1 cm x 1 cm pcs.
7 cm x 5 cm x 0.1 cm pcs 200
8 cm x 0.3 cm - tampon. 20 pcs.
Gel with anaesthetic properties in the form of a pre-filled syringe sterilized with the safest method of vapor sterilization 5 ml having tests for chlorhexidine biocompatibility. x 25pcs 200
Part 125Concentrated three-polymer cream with silicone to protect the skin from fluids and incontinent/faeces, provides moisturizing of dry and chapped skin, without zinc oxide and alcohol content, 24 hours (application every 3-4 episode of incontinent/fecal incontinence), effectiveness skin protection is clinically confirmed on a group of 200 patients (attach a list of publications of clinical trials). Tubka 92 g. pcs 80
Sterile non-alcoholic three-polymer formulation with silicone for the protection of healthy and damaged skin, the addition of plasticizer provides a non-cracking barrier on the skin. Protective effect for 72 hours, the effectiveness of protecting the skin from damage by ur/feces clinically confirmed at the minimum group 900 patients (attach a list of publications of clinical trials). Flakon with atomizer 28 ml. (140 sprays) pcs 50
Part 126Disposable toothbrush made of polypropylene with the possibility of sucking. On one side covered with soft bristles, on the other side a sponge. Total length 18cm, length of cleaning part 2.5cm. Suction hole both on the side of the bristles and in the space between the sponge and bristles. Registered as a medical device of class I. Packaged individually in foil packs, pack a'1 pcs 30
Disposable sponge applicator for oral moisturization. Total length 15.5cm, length of sponge part 2.5cm. sponge made of polypropylene. Registered as a medical device of class I. Packaged individually in foil packaging, packaging a'1 pcs 875
Two-layer disposable body wash in the form of a rectangular glove soaked with two sided nautical PH 5,5 washers, made of 100% polyester fibres. Both layers of washcloth not subfoliated. Size 15cm x 22cm, weight 60g/m2. Produced in accordance with the requirements of ISO 22716:2007 and ISO 9001:2008. Microbial purity confirmed by studies not older than 2017. Packaging a'1pcs The product lacking latex. Expiration date: 5 years from the date of manufacture, the product must be used up to 12 cm after opening packaging pcs 2660
Part 127Absorbent mat for the operating table; sterile for absorption of a large amount of fluids (absorbency of approximately 8l water); double-sided, absorbent from above and underneath; absorbent cartridge equipped with superabsorbent, enabling permanent fluid retention in the core; size 60x38cm (52cm x 30cm); op. 1pc 59
Single use sheet - sterile made of polypropylene non-woven.Green color. Weight 35 g Dimensions 160 x 210 op. and 1 pcs. 1459
Disposable medical - sterile made of polypropylene non-woven woven 25 g/m
Single use heating blanket with dimensions of 210x110 cm; outer layer - non-woven weight 22g/m2, internal layer - polyester weighing 60g/m2 in accordance with EN 13795:2011; possibility of heating a blanket in a greenhouse, 1 p. and 1 pcs. 175 pcs.
Absorbent primer with absorbent on the operating table to allow the transfer of the patient. The absorbent surface reinforced with a resistant film. It provides permanent retention of bacteria including MRSA. Total size 210 cm x 80 cm, absorbent surface size 200 cm x 60 cm. 1 p. and 1 pcs 59
Absorbent primer in size 60 x 90 cm, with absorbent cartridge 60x90 cm, entirely made of breathable non-woven fiber.Absorbent cartridge equipped with superabsorbent, reduces odor, without cellulose content. Provides persistent retention of bacteria including MRSA, Coke in the absorbent core. 1 p. and 1 pcs 205
Hand absorbent napkin 40 cm x 40 cm, barren. 1p. and 1 pcs 292
Wire cover 16 cm x 250 cm, barren 1p and 1 pcs 94
Single use sheet made of polypropylene non-woven foiled. Green color. Weight 25 g Dimensions 160 cm x 210 cm 1op. and 1 pcs 3792
Flexible Case for Operating Lamps Op.1 Op.1 pcs 2334
Part 128Clothing made of non-woven SMS gr. 35g. Untranslucent. Sweatshirt with short sleeve cut, has a “V” cutout completed with a colored clothing, 3 pockets Pants with trots at the waist. Available in 3 colors: blue, purple, green. 13795 compliant material, penetration resistance 1 op a 1pc pc 1459
A cap in the form of a van on the back, pulled off with an elastic band. Made in a side part of non-woven Spunlace 45 g/m2 and polypropylene non-woven. Packaging a'1pcs pcs 5834
A cap in the form of a van tied on the back for the troks. Made entirely of perforated non-woven Spunlace Mesh with a weight of 35g/m2 for excellent breathability and comfort. Dimensions of the bottom: 17cm x 25cm. White troki 25 cm long. Packaging a'1 pcs Available in blue, with white troks pcs 2917
Shoe protectors made of strong and durable polyethylene film with a thickness of 18 μm Blue color. 1p. and 1 pcs 5834
Medical mask made of three layers of non-dusting non-woven fabric, dimensions of the mask 17.5cm x 9.5cm. The length of the troks is 40 cm. Green color. Compatible with 14683 1op. and 1 pcs 50000
Medical mask made of three layers of non-dusting non-woven mask dimensions 17.5cm x 9.5cm. The length of the rubber bands in the non-stretched state 17 cm. Green color. Compatible with 14683 1op. and 1 pcs 50000
Handcuffs with cotton puller 54 pcs packaged a 1 pc 59
Part 129Non-sterile foil apron, individually packaged, pack 1 pcs 4084
Patient shirt made of non-woven SMS 35g in blue. With a V cut under the neck. Size L 1op. a 1 pcs. 2917
Patient shirt made of non-woven SMS 35g in blue. With a Y cut under the neck. Size L 1op. a 1 pcs. 759
Colonoscopy shorts made of polypropylene non-woven fabric 40 g/m
“Disposable barren surgical apron
Full barrier compatible with EN 13795 1-3. Minimum weight 70g/m2, non-woven.
Sleeve finished with an elastic knitted cuff. Seams made by the technique of traditional sewing. Each apron is accompanied by a cellulosic towel 40x40cm X 2, Packed in paper-foil packaging Size: M, L, XL, XXL.
Disposable barren surgical apron with reinforcements.
1p. a 1 pcs” pcs 3063
Part of the 13th"
“pcs 30
Part 130Fiber surgical cap of the Philip type weighing 30 g/m2 with sweat absorbing tapeworm. Tied for troki. Number in packaging1 op a 1 pcs. 292
Full-body surgical mask made of four layers of high-quality nonwovens with a minimum weight of 17g/m2 (one layer). The face layer with no microhairs and specially smoothed without feeling, equipped with a rigid for easy matching of the mask to the shape of the face, tied for trots of up to 40 cm. Steep-resistant, waterproof, with evaporation protection layer, fitted with plastic eye cover. Mask complying with PN EN 14683 IIR. Bacterial barrier of the mask 99.7% (it is necessary to document the bacterial filtration of the mask) .1 op a. 1 pc., designated in accordance with the Medical Devices Act. Color blue pcs 2217
Part 131Lamp holder cover in diameter 4.5cmx15cm. Packaging 1 pcs 47
Sterile surgical napkin in size 75x90cm made of three-layer laminate (two layers of non-woven with a total weight of 43g/m2 and PE film 40μ), with adhesive tape along the longer side. High resistance to fluid penetration min. 900cm H2O. On the unit packaging shall be the manufacturer's information, REF No, series No, expiry date. Double packaging system in cardboard boxes. The material must comply with the requirements of EN 13795, confirm by the technical card of the finished sterile product. Quantity in pack 1 pcs 294
Part 132Fluid capture bag measuring 100x80cm, having a hole filled with a surgical film measuring 38x32cm. The bag is equipped with a stiffer, a valve for connecting the drain and organizers of the wires. Quantity in pack 1 pcs 52
Velcro self-adhesive tape with a size of 5x15cm of 2 pcs. Quantity in pack 1 pcs 420
Sterile three-layer surgical napkin in size 150x175cm made of two non-woven layers with a total weight of 43g/m2 and PE film thickness 40μ. Fluid penetration resistance min. 900cm H2O. On the unit packaging shall be the manufacturer's information, REF No, series No, expiry date. Double packaging system in cardboard boxes. The material must comply with the requirements of EN 13795, confirm by the technical card of the finished sterile product. Quantity in pack 1 pcs 147
Part 1333 layer surgical mask, with rubber bands, weighing 55g/m2, color green packaged 1pcs 2334
3 layer surgical mask, tied to troks, weighing 55g/m2, green or blue, packaged 1pcs 2334
Beret-shaped surgical cap made of perforated polypropylene non-woven, weighing 14g/m2, color green, blue, packed 1pcs 9917
Surgical cap with forehead, tied on the back, made of perforated non-woven, weighing 25g/m2, green colour 1pcs 4084
Unsterile visitation apron, made of soft airy polypropylene non-woven, 21 g/m2, knotted at the waist for troks, green color, universal size, packaged in a pack of 1pcs 5834
“Set — single-use surgical clothing, consisting of hoodies and trousers. Made of breathable non-woven type SMS with a weight of min. 38 g/m2. Antistatic, not fraying. V-neckline, trimmed with white piping, 3 large pockets: one at the top, two at the bottom of the sweatshirt. Latex Free Clothing Finish:
• Pocket finish — top pocket — roll the material inward min. 2 cm
• bottom of the legs of the trousers rolled up, covered
• sleeves of sweatshirts,
• trousers with strap, with sewn troks.
Clothing sizes from S to XXL (clothing in blue in size from XS to XXXL), color availability in other sizes: green, pink or purple. Urbanie complies with absolute use requirements for clothing for operating blocks — standard PN-EN 13795.
“pcs 4200
“Head washing cap for washing the head of the patient without requiring additional soaking of the head, containing in the composition: water, not requiring rinsing, with shampoo and delicate conditioner, odorless. Latex free product. Cap diameter 32 cm (+/- 2 cm). For use at room temperature or for heating in a microwave, for 15-20 seconds.Suitable to wash contaminated hair.
“pcs 234
“Patient shirt inserted through the head, with a cut at the front of the Y type,
Blue, non-lucent, patient intimacy, non-woven SMS type, minimum weight 35 g/sq m in universal size, (equivalent to L), shirt dimensions: girth — 140 cm, length — 120 cm.
Cut under the neck type V plus 20 cm +- 1j
Packed 1 pcs.
“pcs 1634
“Ready-to-wash moisturized gloves with soap and lotionem-for immediate use
Packaging a 1 pcs. Disposable moisturized gloves for washing measurable 15x22 cm. for the patient's toilet, without the need for water, bowls, additional bedridpatient, etc. Glove made of soft, delicate and strong non-woven, in white.Non-woven: 100 g/m2, (composition: 70% polyester, 30% viscose) .Textured non-woven - pattern of squares - for strengthening the efficiency of washing the body. Glove washcloth due to composition provides both skin cleansing and an appropriate degree of moisturizing of the skin.
PH level neutral.
It contains delicate washing and moisturizing substances.
It must not contain phenoxyethanol and silicones.
The product can be heated in a microwave 30 sec. max. 900 W, up to a maximum temperature of 40oC.
“pcs 934
Two-piece clothing for the patient disposable, consisting of hoodies and trousers, of delicate breathable non-woven type SMS 30 g/m2, antistatic, V-neckline, 1 pocket in the bottom of the sweatshirt, elastic trousers, color clothes: dark navy, sizes to choose from S, M, L, XL, XXL to XXXL, foil - packaging method enabling individual selection of pcs size 875
Part 134“Half-masks
Required documents confirming the quality of the assortment by compliance with standards:
1. PN-EN 149+A 1:2010 (or EN 149:2001 +A 1:2009 respectively)
2. Declaration of conformity to comply with the requirements of EU Regulation 2016/425
3. Declaration of conformity with the requirements of the Regulation of the Minister of Health of 17 February 2016 on essential requirements and procedures for assessing the conformity of medical devices (Journal of Laws, item 211) or declaration of compliance with the requirements of Directive 93/42/EEC
4. CE marking
The Ordering Party at the stage of action will require the provision of a copy of the documents confirming the fulfillment of the requirements. "FFP2 pcs 5000,00
“Half-masks
Required documents confirming the quality of the range:
1. Document confirming compliance with PN-EN 149+A 1:2010 (or EN 149:2001 +A 1:2009, respectively)
2. Declaration of conformity to comply with the requirements of EU Regulation 2016/425
3. Declaration of conformity with the requirements of the Regulation of the Minister of Health of 17 February 2016 on essential requirements and procedures for assessing the conformity of medical devices (Journal of Laws, item 211) or declaration of compliance with the requirements of Directive 93/42/EEC
4. CE marking
The Ordering Party at the stage of action will require the provision of a copy of the documents confirming the fulfillment of the requirements. "FFP3 pcs 5000,00
Part 135'Category III protective suit complying with the essential requirements of Regulation (EU) 2016/425 of the European Parliament and of the Council on individual protection measures, including standard EN 14126:2003 on clothing, providing protection against infectious agents, according to at least specified conditions:
• resistance to penetration of contaminated liquid under the influence of hydrostatic pressure - class 4 or higher, resistance to penetration of infectious agents under mechanical contact with substances containing contaminated liquids - class 4 and above,
Resistance to penetration of contaminated liquid aerosols - Class 2 and above
• minimum tearing and piercing strength according to EN 14325:2018 (class 1),
• at least type 4 according to EN 14605:2005+A 1:2009 or type 6 acc. to EN 13034:2005 +A 1:2009,
• hooded, with elastic welts on the cuffs, hood and waist,
• Indoor zipper with adhesive tape In sizes S to XXL, suits must be CE marked and CE certified. The assortment on the basis of standards and equivalent substitutions will require proof of compliance with the relevant document indicated in the SIWZ. ATTENTION! The complete description of the item of the order in this column should be confirmed in the folders and documentation sent on confirmation of compliance with the requirements circled by the Ordering Party” item 1500
Part 136“set for percutaneous tracheotomy by Seldinger technique
With a single-stage “rhino horn” shaped extension with an ergonomic reinforced grip, the distal section smooth with a soft end, covered with a slip layer which, when previously immersed in water, forms a hydrophilic layer, containing a tracheostomy tube with a low pressure cuff (in Sizes: 7mm, 8mm or 9mm) having a mandrin with a hole for a guide catheter with a soft tapered end and handle, 2 inner cannules, tube band, canniul brush” pcs 25
Part 137Seams: absorbable, braided, coated; made of glycolide and L-lactide (90:10); coated with glycolide and L-lactide (35:65) and calcium stearate; tissue support min. 75% after 14 days, 40-50% after 21 days; absorption 56-70 days.
Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 2 4 5 6 7
2/0 26 1/2 Round 70 36
1 43 1/2 round with trocar end in bold 90 72
2 26 1/2 round bold 70 36
2 37 1/2 round bold 70 36
2 48 1/2 round 90 1368
1 40 Hooks Round 70,396
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part 138Seams: absorbable, braided, coated; made of polyglactin 910; coated with polyglactin 370 and calcium stearate; tissue support min. 50% after 5 days after implantation; absorption of approximately 42 days, colorless. Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 2 3 4 5 6
3/0 22 1/2 round 45,144
3/0 22 1/2 round 70,900
1 43 1/2 round with short cutting ending 90 108
1 48 1/2 round with short cutting ending 90,972
1 48 1/2 round 90,612
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part 139Seams: absorbable, monofilament, made of glycconate (72% glycolide, 14% caprolactone, 14% trimethylene carbonate); 70-80% tissue support after 5 days after implantation, absorption after 56 days, colorless. Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 2 3 4 5 6
2/0 51 straight inversely cutting 70 756
2/0 37 1/2 inversely cutting 70 36
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part 14Fiber surgical cap of the Philip type weighing 30 g/m2 with sweat absorbing tapeworm. Tied for troki. Number in a pack of 500 pcs
“pcs 200
Part 140Seams: absorbable, monofilament; made of poly-4-hydroxybutyrate; tissue support 100% - 14days from implantation, 70% - 42 days from implantation, 25% - 140 days from implantation; absorption 13-36 months; filoet.
Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 2 3 4 5 6
1 48 1/2 round 150 loop 216
2 1 1/2 round 150 loop 456
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part 141Seams: absorbable, monofilament; made of poly-p-dioxanone; tissue support min. 90% - 14 days from implantation, 50%-70% - 28-35 days from implantation; absorption 180-210 days, purple.
0 37 1/2 round with trokar-end thickened 90 72
0 40 1/2 round with trokar-end thickened 90 360
1 40 1/2 round 90,252
2 48 1/2 round 90,288
2 48 1/2 Round 90,144
2/0 26 1/2 round 70 72
4/0 2 x 17 1/2 round 90 108
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part 142Seams: absorbable, monofilament; made of glycconate (72% glycolide, 14% caprolactone, 14% trimethylene carbonate); tissue support 50% - 13-14 days from implantation; absorption 60-90 days; folet or colorless.
Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 2 3 4 5 6
5/0 17 1/2 round with trocar ending 70 72
4/0 18 3/8 round with trocar completion 70 36
4/0 26 1/2 round bold 70 108
3/0 22 1/2 round 70,540
3/0 24 3/8 inversely cutting 70 756
3/0 26 3/8 round with trocar completion 70 36
3/0 26 1/2 round 70,396
3/0 x x x 3x45 324
2/0 37 1/2 round with trocar end 90 864
2/0 37 1/2 round with trocar completion 70 432
2/0 26 1/2 round 70 undyed 180
2/0 24 3/8 inversely cutting 70 undyed 72
2/0 26 3/8 round with trocar completion 70 108
2/0 26 3/8 round 70 72
2/0 2x26 2x1/2 round 70 36
2/0 22 3/8 round 70 108
2/0 26 1/2 Round 70 36
2/0 x x x 3x45 648
0 37 1/2 round with trocar termination 70 288
0 40 1/2 round with trocar completion 90 108
0 48 1/2 round with trocar completion 90 360
0 48 1/2 inversely cutting 90 undyed 108
1 37 1/2 round 90,216
1 40 1/2 inversely cutting 90 undyed 72
1 40 1/2 round with trocar termination 90 504
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part 143Seams: non-absorbable, braided; made of polyester; coated with silicone; dyed.
Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 2 3 4 5 6
2/0 30 1/2 round 75 72
0 30 1/2 round 75 108
3 48 1/2 Round 75 White 96
5 60 1/2 cutting round 4x75 48
2 48 1/2 round 75 24
3 48 1/2 Round 75 48
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part 144Seams: non-absorbable, monofilament; made of polyamide; colorless.
Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 2 3 4 5 6
6/0 12 3/8 inversely cutting 75 36
5/0 19 3/8 inversely cutting 75 108
4/0 19 3/8 inversely cutting 45 216
4/0 19 3/8 inversely cutting 75 216
4/0 16 3/8 inversely cutting 75 108
3/0 30 3/8 inversely cutting 75 216
3/0 24 3/8 inversely cutting 75 1152
3/0 24 3/8 inversely cutting 45 1260
2/0 24 3/8 inversely cutting 75 396
2/0 24 3/8 inversely cutting 45 180
2/0 39 3/8 inversely cutting 75 1296
2/0 39 3/8 inversely cutting 90 756
0 39 3/8 inversely cutting 75 504
0 39 3/8 inversely cutting 90 432
1 90 3/8 inversely cutting 100 216
2 90 3/8 inversely cutting 100 48
2 90 3/8 inversely cutting 100 72
4/0 19 3/8 inversely cutting with precision blade 45 72
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part 145Seams: non-absorbable, monofilament; made of polypropylene-polyethylene; blue.
Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 2 3 4 5 6
7/0 2X10 2X1/2 2XRound 75 36
5/0 17x2 needles 2X1/2 2XRound 90 72
2/0 30 1/2 round 75,252
1 37 1/2 round 75,144
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part 146Seams: non-absorbable, braided; made natural silk fibers; coated with pure beeswax; black.
Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 2 3 4 5 6
0 48 3/8 inversely cutting 75 72
0 30 1/2 round 75,144
1 37 1/2 round 75 108
2 37 1/2 round 75 180
2 37 1/2 round bold 75 36
2/0 24 3/8 inversely cutting 75 36
2/0 26 1/2 round 75,144
2/0 51 3/8 inversely cutting 75 36
4/0 15 1/2 inversely cutting 75 36
4/0 — — 150 48
4 — — — 150 108
1 — — — 2 x 75 108
3/0 22 3/8 round 70 108
4/0 21 1/2 inversely cutting 75 36
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part 147Seams: absorbable; braided; made of polyglycolic acid; coated with glycconate; tissue support 50% - 5days after implantation, 0% - 10-14 days from implantation,; absorption 42days; colorless.
Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 2 3 4 5 6
1 43 1/2 Trocar Round 90 108
1 48 1/2 Trocar Round 90 180
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part 148Seams: non-absorbable, monofilament; made of polypropylene;; blue.
Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 2 3 4 5 6
1 37 1/2 round 75,144
1 30 1/2 round bold 75 36
2/0 30 1/2 round 75 72
5/0 2 X 17 1/2 Round 90 72
7/0 2 X 10 1/2 Round 75 36
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part 149Stitches: absorbable, braided; made of glycolide and lactide; coated with captolactan, glycolide and calcium stearyoilclate, tissue support 80% - 14days from implantation, 30% - 21 days from implantation; absorption 2-3 months; filoet.
Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
5 6 7 8 9 10
1 - - - 150,180
4/0 22 1/2 round 75 144
1 37 1/2 circles 75 1296
0 37 1/2 round 75,684
0 27 1/2 rounds 75,396
1 30 1/2 round 75 72
2 37 1/2 circles 75,504
2 48 1/2 rounds 90 2772
2/0 37 1/2 round 75 216
2/0 26 1/2 round 75,396
3/0 26 1/2 round 75,576
1 37 1/2 round 90,144
1 48 1/3 round 90 144
0 6 x 75 24
0 3 x 75,384
1,150,108
2 12 x 45,144
2,13,144
2/0 3 x 75,168
2/0 6 x 75,192
3/0 6 x 75 48
3/0 150 48
2/0 52 Loop 6
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part of the 15th“Barren dressing set for vacuum wound therapy consisting of foam dressing made of elastic black hydrophobic foam measuring 10cm x 7.5cm x 3.3cm, self-adhesive pad with port height 5 mm and within 8x8 cm connected by a two-light silicone drain and plug enabling closure of the drain light and 3 self-adhesive transparent polyurethane films 15cmx20 cm.
All barren packed, placed on a polyprpylene tray.” pcs 72
“Barren dressing set for vacuum wound therapy consisting of: foam dressing of elastic, black hydrophobic foam measuring 18cm x 12.5cm x 3.3cm, self-adhesive pad with port 5 mm height 8 x8 cm combined with a two-light silicone drain and plug enabling closure of the drain light and 2 self-adhesive transparent polyurethane films 20cmx30 cm.
The whole barren packed, placed on a polyprpylene tray.” pcs 36
“Barren dressing set for vacuum wound therapy consisting of: foam dressing made of elastic black hydrophobic foam measuring 25cm x 15cm x 3.3cm +/- 1 cm, self-adhesive pad with a port of 5 mm height 8 x8 cm combined with a two-light silicone drain and plug to close the drain light and 3 self-adhesive transparent polyurethane films 20cmx30 cm.
The whole barren packed, placed on a polyprpylene tray.” pcs 15
Part 150Seams: absorbable, braided, coated; made of polyglactin 910; coated with polyglactin 370 and calcium stearate; tissue support min. 75% after 14 days after implantation; 50% after 21 days after implantation; 25% after 28 days after implantation; absorption of approximately 70 days, purple.
Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 2 3 4 5 6
2 48 1/2 stratifying 90 324
2 36 1/2 round 90,684
1 31 cutting round hook 70 672
1 70 1/2 Round 70 12
1 48 1/2 round 75 12
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part 151Seams: absorbable, monofilament; made of PDO; two-way arrangement of anchors; tissue support 80% - 14days from implantation, 70% - 30 days from implantation, 40% - 45 days from implantation; absorption 6 months; filoet.
Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 2 3 4 5 6
1 48 1/2 round 36 x 36 300Deviations in thread length are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part 152Non-absorbable, polypropylene mesh, monofilament for supplying inguinal hernias, elastic structure, with the possibility of notching and bluntness of edges; thickness: 0.39 - 0.40 mm, weight 36-38 g/m2, size 6cm x 14 cm (TOL.+1 cm) factory-shaped iron shape without incisions 70
Non-absorbable, polypropylene mesh, monofilament for supplying inguinal hernias, elastic structure, with the possibility of notching and bluntness of edges; thickness: 0.39 - 0.40 mm, weight 36-38 g/m2, size 6cm x 14 cm (TOL.+1 cm) factory-shaped iron shape incision and opening for seed return 15
Non-absorbable, polypropylene mesh, monofilament for supplying inguinal hernias, elastic structure, with the possibility of notching and bluntness of edges; thickness: 0.39 - 0.40 mm, weight 36-38 g/m2, size 4,5cm x 10 cm (TOL.+1 cm) factory-shaped iron shape without incisions 30
Non-absorbable, polypropylene mesh, monofilament for supplying inguinal hernias, elastic structure, with the possibility of notching and bluntness of the edges; thickness: 0.39 - 0.40 mm, weight 36-38 g/m2, size 7,5cm x 15 cm (TOL.+1 cm) 70
Part 153Absorbable band 3mm wide for supplying parenchymal organs, length 60cm, needle length 85mm, 1/2 circular blunt. Absorption 60-90days pcs 6
Part 154Disposable leather stapler for closing long wounds. 35 staples made of Teflon-coated stainless steel, dimensions of staple after closing 6.9x4,2mm 606 pcs.
“Circular stapler with an anvil outer diameter of 25.5mm and a blade diameter of 17mm, curved single use for internal use. Anvil stocked with a hole for dragging the guide seam. The Stapler is equipped with:
— an integrated automatic safety lock that prevents accidental firing, before and after anastomosis,
— a rotating blade system that minimizes the traumatization of tissues during cutting,
— 20 titanium alloy staples in two rows with controlled tissue pressure and adjustable staple closure height ranging from 1mm to 2.5mm, open staple height 5mm
- Butterfly control knob for easy closing and opening of the stapler.
Stapler packaged one at a time.
“pcs. 5
“Circular stapler with an anvil outer diameter of 29.5mm and a blade diameter of 20.5 mm, curved single use for internal use. Anvil stocked with a hole for dragging the guide seam. The Stapler is equipped with:
— an integrated automatic safety lock that prevents accidental firing, before and after anastomosis,
— a rotating blade system that minimizes the traumatization of tissues during cutting,
— 24 titanium alloy staples in two rows with controlled tissue pressure and adjustable staple closure height ranging from 1mm to 2.5mm, open staple height 5mm
- Butterfly control knob for easy closing and opening of the stapler.
Stapler packaged one at a time.
“pcs. 20
Part 155Seams: non-absorbable, monofilament; made of polyamide;
Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 2 3 4 5 6
5/0 19 3/8 inversely cutting 75 108
4/0 19 3/8 inversely cutting 45 216
4/0 19 3/8 inversely cutting 75 216
4/0 16 3/8 inversely cutting 75 108
3/0 30 3/8 inversely cutting 75 216
3/0 24 3/8 inversely cutting 75 1152
3/0 24 3/8 inversely cutting 45 1260
2/0 24 3/8 inversely cutting 75 396
2/0 24 3/8 inversely cutting 45 180
2/0 39 3/8 inversely cutting 75 1296
2/0 39 3/8 inversely cutting 90 756
0 39 3/8 inversely cutting 75 504
0 39 3/8 inversely cutting 90 432
1 90 3/8 inversely cutting 100 216
2 90 3/8 inversely cutting 100 48
2 90 3/8 inversely cutting 100 72
5/0 16 3/8 cosmetic inverse cutting (biconcave) PRIME 45 12
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
Part 156Rapid-absorbable suture made of synthetic digestible monofilament composed of glycopolymer and e-caprolactone. Tissue support: 7 days - 60-50%, 14 days - 30-20%, 21 days - 11-0%. Total absorption of the seam - 90-120 days
Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 2 3 4 5 6
3/0 22 1/2 round 70,540
3/0 24 3/8 inversely cutting 70 756
3/0 26 1/2 round 70,396
3/0 x x x 3x45 324
2/0 37 1/2 round-cutting 90 864
2/0 37 1/2 round-cutting 70,432
2/0 26 1/2 Round 70 36
2/0 x x x 3x45 648
0 37 1/2 round-cutting 70,288
0 48 1/2 round-cutting 90 360
1 40 1/2 round-cutting 90 504
4/0 16 3/8 cosmetic inverse cutting (biconcave) PRIME 45 12
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
Part 157Seams: absorbable, braided, coated; made of glycolide and L-lactide (90:10); coated with glycolide and L-lactide (35:65) and calcium stearate; tissue support min. 75% after 14 days, 40-50% after 21 days; absorption 56-70 days.
Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 2 3 4 5 6
2 37 1/2 round bold 70 36
2 48 1/2 round 90 1368
1 40 Round cutting hooks 70,396
1 37 1/2 round 90,144
1 48 1/2 round 90,144
1 - - - 150,180
4/0 22 1/2 round 75 144
1 37 1/2 circles 75 1296
0 37 1/2 round 75,684
0 27 1/2 rounds 75,396
1 30 1/2 round 75 72
2 37 1/2 circles 75,504
2/0 37 1/2 round 75 216
2/0 26 1/2 round 75,396
3/0 26 1/2 round 75,576
0 5 x 70 24
0 2 x 70,384
1,150,108
2,13,144
2/0 3 x 75,168
2/0 5 x 70,192
3/0 5 x 70 48
3/0 150 48
3/0 19 3/8 cosmetic inverse cutting (biconcave) PRIME 45 12
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
Part 158Seams: absorbable, braided, coated; made of polyglactin 910; coated - glycolide and L-lactide (30:70) and calcium stearate; tissue support min. 50% after 5 days after implantation; absorption of approximately 42 days.
Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.) Price of one sachet (net)
1 2 7 8 9 10 11
3/0 22 1/2 round 70,900 £9.95
1 43 1/2 round-cutting 90 108 15,72 zł
1 48 1/2 round-cutting 90,972 £15.72
1 48 1/2 round 90,612 £15.58
5/0 11 3/8 cosmetic inverse cutting (biconcave) PRIME 45 12 20.79 zł
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
Part 159Seams: non-absorbable, monofilibres; made of stainless steel; designed for patella treatments
Poz. Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 5 6 7 8 9 10
1 7 120 1/2 inversely cutting 60 12
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braided/monofilament), absorbability (absorptive/non-absorbable)
Seams: non-absorbable, braided; coated with silicone, made of polyethylene terephthalate. ;
Part 16A 300 ml barren discharge tank with air and carbon filters, gelling agent built into the tank, internal chamber system and revision window combined with two-light drain 180 cm. pcs 48
Barren 800 ml discharge tank, with air and carbon filters, gelling agent built into the tank, internal chamber system and revision window, combined with a two-light drain of 180 cm. pcs 15
Part 160Seams: non-absorbable, braided; coated with silicone, made of polyethylene terephthalate. ;
Poz. Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 5 6 7 8 9 10
1 5 77 3/8 inversely cutting 75 216
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part 161Seams: absorbable, monofilament; made of PDO; two-way arrangement of anchors; tissue support 80% - 14days from implantation, 70% - 30 days from implantation, 40% - 45 days from implantation; absorption 6 months; purple. Poz. Thickness of the thread length of the needle (mm) Curvature of the needle section/Type of needle thread length (cm) Number of sachets (pcs.)
1 5 6 7 8 9 10
1 1 48 1/2 round 36 x 36 648
Deviations in the length of the threads are allowed: +/- 5cm
Deviations in the length of the needle are allowed: with a needle length of 22 mm +/- 1 mm, with a needle length of 26 mm +/-2 mm, with a needle length of 40 mm +/-4 mm,
All items in the package - seams of one manufacturer, legibly marked unit and bulk packaging, folded packaging secured with foil with banderol,
All sachet with description in whine. Polish - chemical composition, thread structure (braid/monofilament), absorbability (absorptive/non-absorbable)
Part 162Poz. DESCRIPTION and grid size
1 2
1. Sterile surgical separating mesh, polypropylene, monofilament (83%), having an anti-adhesion layer made of ePTFE (17%) and a marker to facilitate the arrangement of a grid with a weight of 120g/m
2. Sterile surgical polypropylene mesh, monofilament for supplying groin hernias with elastic strutur, light weight 37.8 g/m
3. Sterile surgical polypropylene mesh, monofilament for supplying groin hernias with elastic strutur, light weight 37.8 g/m
4. Sterile surgical polypropylene mesh, monofilament for supplying groin hernias with elastic struture, light weight 37.8 g/m
5. Sterile surgical polypropylene mesh, monofilament for supplying inguinal hernias with elastic structure, weight 100 g/m
6. Sterile surgical polypropylene mesh, monofilament for supplying inguinal hernias with elastic structure, weight 100 g/m
7. Sterile surgical polypropylene mesh, monofilament for supplying inguinal hernias with elastic structure, weight 100 g/m
Seam Removal Kit - Sterile, disposable set consisting of: 3 pcs tupfer Tampons 20 cm x 20 cm, 1 pc Anatomical Metal Tweezers 12 cm, 1 pc plastic tweezers 12.5 cm, 1 pcs blade No. 12. All packed in a Hard Blister package. The set contains a large, legible bar code label with two TAG labels, containing: index, series number, LOT, for keeping medical records. pcs 2 400
Part of the 18thCentral insert kit - sterile consisting of 6 pcs cotton-gauze compresses 7.5 cm x 7.5 cm, 4 cotton-gauze tupfers 20 cm x 20 cm, 1 pc plastic handles 14 cm, 1 pcs plastic tweezers 12.5 cm, 1 pc non-adhesive non-clingy non-clingy dimensions 45cm x 75cm, 1pc 45cm x 75cm non-woven napkin with adjustable barrier, adhesive hole; 1pc luer syringe 10 ml, 1 pc needle 1.2 x 40 mm (18G x 1 ½), 1 pc needle 0.8 x 40 mm (21G x 1 ½), 1 pc scalpel no 12, 1 pc needle 13 cm, 1 piece of dressing Transparent of polyurethane film 10 cm x 15 cm. Entire packaged in a Hard Blister package. The set contains a large, legible barcode label with two TAG labels, containing: index, series number, LOT, for keeping medical records. pcs 660
Part of the 19thWire Anesthesia Kit — sterile consisting of: 1 pc Mayo Table napkin 75cm x 45 cm, 1 pc injection needle 0.5 x 38 mm (25G), 1 pc injection needle 1.2 x 40 mm (18 G), 1 pc Luer type syringe capacity 2 ml, 1 pc Luer capacity 5 ml, 1 pc made of double-layer, pha-barrier non-woven conforming to standard (EN 13795- 1,2,3) weighing min 55g/m2, absorbency of the outer layer min 440%, fluid penetration resistance > 200 cm H2O (according to EN 20811), tear-resistant > 290 kPa (according to EN 13938-1), hole in shape Rhombus 10x12 cm and adhesive area for attaching to the patient's back, 1 pc pean forceps 14 cm, 6 pcs tupfers 15 cm x 15 cm, 3 pcs non-woven compresses 10 cm x 10 cm. The whole thing packed in a foil paper bag. The set contains a large, legible bar code label with four TAG labels, containing: index, series number, LOT, for keeping medical records. pcs 1 380
Part 22 “Kit with U cutout napkin
Minimum composition and dimensions:
1) Top Surgical Service with Adhesive Tasma 240x175 — 1pcs
2) Bottom Surgical Service 200x260cm with self-adhesive excision 20x102cm - 1pc
3) Self-adhesive tape cover 90x75cm, layered construction, additional absorbent reinforcement in the critical zone — 1 pcs.
4) Table coverlet 150x190cm, absorbent layer 75x190cm — 1pcs.
5) Adhesive tape impermeable elastic 9x49cm - 1pc
6) Absorbent towels 18x25cm — 4pcs
7) Mayo table cover 79x145cm, absorbent layer 65x85cm - 1pcs
Material requirements:
Items 1,2, made of three-layer min. laminate with a weight of > 63 g/m2 having additional reinforcement (fourth layer) in the non-woven critical zone of 50g/m2, total weight in the critical zone min. 113 g/m2, resistance to liquid penetration (hydrostatic pressure) to the entire surface of the servets min. 100cm H2O, one of the layers was PE film, dry/wet push strength (critical zone) > 62/49 kPa, the napkins meet the requirements of PN EN 13795-3 High quality,
Packaging paper-foil bag or foil with label in Polish with at least two stickers to be pasted in medical records as no. The product sterilized according to the standards required by law.
Quantity in pack 10 pcs” pcs 70
Part 20“Absorbent barren dressing built of 4 layers of materials with different properties; absorbent layer of soft fibrous cellulose, absorbent layer surrounded by thin non-woven, to evenly distribute effusion over the entire absorbent surface; The other side of the non-woven layer permeable for air, but fluid non-permeable, which counteracts the penetration of the secretions outward and protects the wound from dirt; The whole of a two-layer non-woven, whose outer layer, of hydrophobic polyamide fibers, prevents the dressing from sticking to the wound. Inner layer, of fibres
Cellulosic, hydrophilic properties and allows rapid movement of the exudate to
Absorbent layer; Individual packaged dressing, visible name on the unit packaging, expiration date, series.
Size 10 cm x 20 cm” pcs 1000
“Absorbent barren dressing built of 4 layers of materials with different properties; absorbent layer of soft fibrous cellulose, absorbent layer surrounded by thin non-woven, to evenly distribute effusion over the entire absorbent surface; The other side of the non-woven layer permeable for air, but fluid non-permeable, which counteracts the penetration of the secretions outward and protects the wound from dirt; The whole of a two-layer non-woven, whose outer layer, of hydrophobic polyamide fibers, prevents the dressing from sticking to the wound. Inner layer, of fibres
Cellulosic, hydrophilic properties and allows rapid movement of the exudate to
Absorbent layer; Individual packaged dressing, visible name on the unit packaging, expiration date, series.
Size 13.5cm x 25cm” pcs 500
Part of the 21stBarren silicone contact layer protects the skin and prevents adhesion of secondary dressing 7.5 x 10 cm (S) pcs 50
Barren silicone contact layer protects the skin and prevents the adhesion of the secondary dressing, left 20 x 10 cm (M) pcs 50
Barren silicone contact layer protects the skin and prevents the adhesion of the secondary dressing, left 20 x 30 cm (L) pcs 50
Part of the 22nd“Occupancy for hip surgery. Set packaged in outer film packaging - paper,
Included:
1 Instrumentary table cover made of polypropylene film reinforced with three-layer polypropylene SMS, 152x228 cm ±10cm.
1 Mayo table cover made of polypropylene film reinforced with three-layer polypropylene SMS 80x144 cm ±5cm.
1 Adhesive tape made of polypropylene -10 cm ±2cm x 55 cm ±5cm.
1 Lib cover made of polypropylene, elastic (enabling easy application and fitting to the anatomical shape of the limb without additional attachment and sealing) latex free, waterproof for fluids and secretions, of non-slip structure, originally coiled and enabling aseptic attachments thanks to 2 application strips that allow it to gradually expand on the limb, minimizing the extrusion of air into a previously disinfected operated place in L size (25x121 cm +/- 2 cm).
1 U-shaped central cut fabric, impermeable to liquids and secretions, made of polypropylene film, without latex, polyethylene, polyester and cellulose 152x178 cm ±5cm.
U -10 cm ±2 cm x 53 cm ±5cm
With adhesive tape along the U notch.
1 Type U - Orthopedic, made of polypropylene SMS, no latex, polyethylene, polyester and cellulose 224x318 cm ±10cm.
U -15 cm ±2 cm x 137 cm ±5cm central notch;
With adhesive tape along the U notch;
Reinforcement (% run off ≤ 75%, for critical zone - PN - EN ISO 9073-11.2006 according to section 5.7 part 2 of Standard PN-EN 13795- 2:2004);
Meeting high requirements for the critical and less critical zone at least:
Dry microbial penetration resistance: for less critical zone ≤ 2.0 log (10) CFU,
Wet microbial penetration resistance: for Critical Zone 6.0 Barrier Index,
Purity — solid molecules: for both zones ≤ 3.5log (10) PM,
Dropping: for both zones ≤ 4.0 log (10),
Microbial purity: for both zones ≤ 2.0 log (10) CFU/dm2,
Liquid penetration resistance (hydrostatic pressure): for critical zone > 100, for less critical ≥ 10cm H2O,
Push strength — dry: for critical ≥ 40kPa, for less critical ≥ 40kPa,
Wet push strength: for critical zone ≥ 40 kPa; dry tensile strength: for critical ≥ 20N, less critical ≥ 20,
Tensile strength — wet: for critical zone ≥ 20N,
At the same time, satisfying complementary parameters: flammability 1st class is allowed to melt the material in contact with fire and other thermal factors (e.g. diathermia).
1 Operated site limiting and forming an anesthesiological paravan, without latex, polyethylene, polyester and cellulose content, 157x269 cm ±10cm with integrated two shoulder covers:
With adhesive tape along the edge limiting the operated place and with three holes integrated into the napkin (+/- 1 hole) for repeated carrying of cables and drains through them;
Reinforcement (% run off ≤ 75%, for critical zone - ISO 9073-11.2006 according to section 5.7 of Part 2 of Standard PN-EN 13795- 2:2004);
Meeting the requirements for both zones as for type U — orthopedic.
Pc. 180
Part 23“Occupancy for knee surgery. Set packaged in outer film packaging - paper,
Included:
1 Instrumentary table cover made of polypropylene film reinforced with three-layer polypropylene SMS, 152x190 cm ±5cm.
1 Mayo table cover made of polypropylene film reinforced with three-layer polypropylene SMS 80x144 cm ±5cm.
1 Adhesive tape made of polypropylene -10 cm ±2cm x 55 cm ±5cm.
1 Lib cover made of polypropylene, elastic (for easy application and fit to the anatomical shape of the limb without additional attachment and sealing) latexe-free, waterproof for fluids and secretions, with a non-slip structure, originally coiled and enabling aseptic attachments thanks to 2 application strips that allow it to gradually expand on the limb, minimizing the extrusion of air into a previously disinfected operated place in S (17x76 cm +/- 2 cm).
1 Lip jacket, made of polypropylene SMS, without latex, polyethylene, polyester and cellulose - 274x315 cm ±15cm.
With a hole with an initial diameter of 6 cm ±2cm, made of elastic material (latex free), (allowing easy application and fitting to the anatomical shape of the limb without additional attachment and sealing);
Integrated with the napkin three holes (+/- 1 hole) for repeatedly carrying cables and drains through them and with integrated two shoulder covers;
Reinforcement (% run off ≤ 75%, for critical zone - ISO 9073-11.2006 according to section 5.7 of Part 2 of Standard PN-EN 13795- 2:2004);
Meeting high requirements for the critical and less critical zone at least:
Dry microbial penetration resistance: for less critical zone ≤ 1.0 log (10) CFU,
Wet microbial penetration resistance: for Critical Zone 6.0 Barrier Index,
Purity — solid molecules: for both zones ≤ 2.5 log (10) PM,
Dropping: for both zones ≤ 3.0 log (10),
Microbial purity: for both zones < 2.0 log (10) CFU/dm2,
Liquid penetration resistance (hydrostatic pressure): for critical zone > 150, for less critical ≥ 50 cm H2O,
Push strength — dry: for critical > 300 kPa, for less critical > 140 kPa,
Ejection strength — wet: for critical zone > 300 kPa,
Dry tensile strength: for critical > 90/90 N, for less critical > 30/50 N,
Tensile strength — wet: for critical zone > 100/100 N,
At the same time fulfilling complementary parameters; flammability: 1st class is allowed to melt the material in contact with fire and other thermal factors (e.g. diathermia).
Pcs. 120
Part 24“Microbial barrier and security of the operated site. Microbial barrier based on cyanoacrylate, immobilizing microbes and sealing the skin. Disposable rigid sponge applicator containing inside a glass ampoule with liquid and a filter that allows you to activate and apply the barrier layer with one hand. The resulting surface of the microbial barrier - the operating field 25 cm by 25 cm (625 cm2.).
“pcs 130
Part of the 25th“Surgical mask of type FLUIDSHELD (EN 14683 Type IIR).
Protection against liquids from the exterior 160mmHg (ASTM).
Bacterial filtration (BFE) ≥ 98%.
Inhaled and exhaled air resistance (Delta P) < 29 Pa/cm
With a shield to protect your eyes.
Colorful designation of the level of protection.
With tapeworms for binding.” pcs. 1500
Part of the 26th“Surgical apron, high requirements according to standard 13795, reglan type, made non-woven polypropylene SMS without latex, cellulose, polyester and polyethylene, vapor permeable throughout the surface, additional reinforcement at the critical site made of polypropylene SMS without foil, coloured marker on the top seam identifying the purpose and level of protection, including at least one sterile towel, sterile, packaged
In the outer packaging foil paper, internal non-woven packaging ensuring the preservation of sterility when removed from the outer packaging or in case of loss of tightness or tear of the outer packaging. The apron is folded in a package in a manner that prevents accidental dirt when put on, the inside side of the apron outside. Such a folding makes it possible to take the apron with your hand without a sterile glove and put it in a barren manner. At the same time complying with the requirements for individual parameters described in EN 13795:
Dry microbial penetration resistance: for less critical zone ≤ 1.0 log (10) CFU;
Wet microbial penetration resistance: for critical zone ≥ 5.0 Barrier Index;
Purity — solid molecules: for both zones ≤ 2.5 log (10) PM;
Dropping: for both zones ≤ 3.0 log (10);
Microbial purity: for both zones < 2.0 log (10) CFU/dm2;
Liquid penetration resistance (hydrostatic pressure): for critical zone ≥ 100 cm H2O and less critical zone > 50 cm H2O;
Push strength — dry: for critical zone > 250 kPa;
Ejection strength — wet: for critical zone > 250 kPa;
Dry tensile strength: for critical zone > 60 N;
Tensile strength — wet: for critical zone > 60 N;
Flammability: 1st class (described in NFPA-702).
In sizes:
Roz. L (length:113 cm/width:156 cm/bottom sleeves:88 cm),
Roz. L-XLong (length:133 cm/width:156 cm/bottom sleeves:87 cm),
Roz. XL (length:118 cm/width:156 cm/bottom sleeves:95 cm),
Roz. XL-Xlong (length:138 cm/width:174 cm/bottom sleeves:95 cm).
“pcs. 1000
“Surgical, barrier apron, for high-risk procedures (for treatments in patients with HIV, HCV, HBV, etc.) made of non-woven S/FSMS (polypropylene), without latex, cellulose and polyethylene content
Sterile surgical barrier apron, reglan type, included min. 1 sterile towel, packaged in a packaging of foil paper, inboard non-woven packaging ensuring sterility after removal from the pack in case of tear from the Packaging. The apron is folded in the package in a way that prevents accidental dirtiness when put, the inside side of the apron outside, which allows you to take the apron with your hand without a sterile glove and put it in a barren manner with the use of a carton at the trunk. An apron providing at least minimum parameters according to Standard PN-EN 13795 or equivalent for high critical and less critical zone requirements and meeting the following requirements:
— Dry resistance to microbial penetration: for less critical zone min. ≤ 1 CFU
— Purity — solid molecules: for both zones min. ≤ 2.0 IPM
— Dropping: for both zones min. ≤ 2 log 10
— Microbial purity: for the mine critical zone. < 100 CFU/100 cm2
— Push strength — dry: for s. critical min. > 200 kPa; for s. less critical min. > 100 kPa
— Ejection strength — wet: for critical zone min. 200 kPa
— Liquid penetration resistance (hydrostatic pressure): for the critical zone min. > 200 cm. H2O; for less critical zone min. > 50 cm. H2O
— Wet microbial penetration resistance: for critical zone 6 IB
— Having a level of protection for AAMI 4 aprons or equivalent
Sizes (tolerance: ±5 cm):
— L: Length (front, neck down) 115 cm./ Length (back, neck down) 125 cm./ Sleeve length (from armpit to cuff) 55 cm./Coat width (i.e., total bottom
Part of the 27th“Operator's cap.
Head cover with absorbent layer on the entire side surface, airy from the top.” pcs. 1800
Part of the 28th“Surgical boots — long (above the ankle) made of non-woven SMS, designed for moderate contact with fluids associated with splash, additionally having min 5 non-slip strips 0.5 — 1cm wide each. Universal size and XL.
.” pcs. 100
Part of the 29th“Cystoscopy kit. Minimum lineup of the set:
- 1 rope for table covering instrumentary size 120cm x 140cm (set wrap)
— 2 lower limb covers for size 75cm x 120cm
- 1 cystoscopy napkin 90cm x 175cm with self-adhesive hole in the perineal region 9 x 15cm, centrally located.
Occupancy made of 2-layer laminate Individual layers are connected evenly by co-extrusion technique. The occupancy material meets the requirements of PN EN 13795. Dry push strength min. 93 kPa, wet min. 113 kPa. On the outer packaging, two self-adhesive labels for the purposes of documentation containing the catalogue number, LOT, expiry date and manufacturer's data. Sterilization odorless EO, packaging foil paper.” pcs. 800
Part 3“Treatment kit [input] ventral perineal in the composition of:
— Surgical service for ventral-perineal treatment with dimensions of 250/175/270x260 cm integrated with anesthesia screen and leg, has a self-adhesive opening in the abdominal area measuring 25x30 cm, surrounded by an absorbent layer and a hole in the perineum area measuring 13x24 cm with protection in the form of an integrated napkin measuring 38x64 cm. Occupancy is equipped with wire organizers and four integrated pockets
— napkin with adhesive tape 75 x 75 cm - 1 pc,
— self-adhesive tape type RZEP - 1 pcs
— adhesive tape 9 x 49 cm - 1 pc,
— absorbent towels - 4 pcs,
- MAYO table cover 79 x 145 cm - 1 pc
- table napkin - (wrap set) 150x190 cm
The kit must meet the requirements high according to PN EN 13795 1-3 while at the same time pushing strength in the critical zone min. 110 Kpa
The basic material of the main napkin is made of min. 2 layers, one of the layers should be PE film with a thickness of 50 - 55 microns, while the drug is an absorbent layer with a weight of min. 20 g/m2, additional reinforcement in the critical zone forming the third layer - laminate with a weight of min. 60 g/m2. Quantity in pack 10 pcs” pcs 5
Part 30“A set for urological surgeries. Minimum lineup of the set:
- 1 rope for table covering instrumentary size 150cm x 190cm (set wrap)
— 1 self-adhesive non-woven tape size 9cm x 25cm
- 1 TUR 175/260cm x 210cm treatment service with 125cm integrated lower limb covers, with integrated fluid bag with strainer and valve for connecting the drain and latex finger cover, the napkin additionally has a hole in the crotch area with a diameter of 5cm and a self-adhesive hole sububic with a diameter of 8cm. Operating servet made of 2-layer laminate Individual layers are connected evenly by co-extrusion technique. The limb covers and the lower part of the main napkin made of PE foil. The occupancy material meets the requirements of PN EN 13795 and AAMI PB70, level 3. Dry push strength min. 93 kPa, wet min. 113 kPa. On the outer packaging, two self-adhesive labels for the purposes of documentation containing the catalogue number, LOT, expiry date and manufacturer's data. EO odorless sterilization, packaging foil paper.” pcs. 200,00
Part of the 31stSterile lower limb cover measuring 50cm x 110cm, made of 2-layer laminate (polypropylene non-woven and polyurethane film) weighing min. 57 g/m2. The material complies with high standards EN 13795. The unit packaging has min. 2 self-adhesive labels containing the manufacturer's data, catalogue number, LOT and expiration date. Outright Sterilization EO. Op. a'2pcs. 1000,00
Part of the 32thSterile napkin 75cm x 90cm, made of double-layer laminate (polypropylene non-woven and polyethylene film) with a weight of 40.2 g/m2. The material meets the requirements of EN 13795 standard. Single napkins packed in paper-film packaging, placed in a cardboard dispenser and external cardboard.
Sterile napkin 150cm x 200cm, with self-adhesive hole diameter 12cm, located decentrally, made of 2-layer laminate (polypropylene non-woven and polyethylene film) weighing min. 57 g/m2. The material complies with high standards EN 13795. Repositionable adhesive for free gluing and peeling without the risk of damage to the material. Single napkins packed in paper-foil packaging, placed in a cardboard dispenser and outdoor cardboard. The unit packaging shall have 2 self-adhesive labels for the purposes of documentation containing the catalog number, LOT, expiry date and manufacturer's data. Outright sterilization EO. pcs. 400,00
Sterile napkin 75cm x 90cm, made of double-layer laminate (polypropylene non-woven and polyethylene film) with a weight of min. 57 g/m2. The material complies with high standards EN 13795. Single napkins packed in paper-film packaging, placed in cardboard dispenser and outdoor cardboard. The unit packaging shall have 2 self-adhesive labels for the purposes of documentation containing the catalog number, LOT, expiry date and manufacturer's data. Outright Sterilization EO. pcs 350,00
Part of the 33th“A set for treatments on the limb. Minimum lineup of the set:
1 Instrumentary table napkin 150cm x 190cm (set wrap)
1 tablecloth for Mayo 80cm x 145cm table
2 hand towels 20cm x 30cm
1 non-woven adhesive tape 9cm x 25cm
1 self-adhesive film tape 10cm x 50cm
1 operating servo 150cm x 150cm
1 orthopedic cover for limb made of polyethylene film 33cm x 55cm
1 limb napkin 200cm x 300cm with 7cm self-sealing hole and reinforcement in the critical zone
Servets made of 2-layer material, connected evenly by co-extrusion technique. Additionally, in the area of the operational field, reinforcement made of dark green hydrophilic non-woven polypropylene spunbond evenly connected to the base material by means of melt adhesive. Material weight in reinforced area min. 99g/m2. Extrusion strength in dry-reinforced area min. 94 kPa, wet min. 114 kPa. The material must meet the requirements of PNEN13795 for surgical and AAMI PB70, level 3. The kit has two adhesive labels containing the catalog number, LOT, expiration date and manufacturer's data. The opening direction is clearly marked on the package. Outright Sterilization EO.” pcs. 50,00
Part of the 34thSterile foil cover for an X-ray in the shape of a ball with a diameter of 120cm (when pulled) and 65-70cm (at rest), made of a strong transparent PE film with a thickness of 0.05mm, pulled down with a tightly elastic rubber band. The packaging has two self-adhesive labels for documentation, containing the following information: expiry date, series number, REF, and manufacturer's name. Outright sterilization, EO. Paper unit packaging, outer packaging in the form of a dispener carton. pcs. 350,00
Part of the 35thBag for collection of fluids and tissues; 60cm x 90cm; made of film with a thickness of 50μm. The bag has a U notch surrounded by split adhesive tape ending with tabs without glue and horizontal adhesive tape. Bag equipped with a rigid for modeling, a valve for draining fluids and a sieve for tissue collection; bag for use in various surgical procedures. pcs. 50,00
Part of the 36thThree-layer surgical mask with horizontal attachment of trocs providing a larger respiratory chamber, suitable for people with stubble, weighing 58 g/m2. Filter material, inner and outer layers and ultrasonic welded troks. Compliant with Standard 14683, Type II, BFE > /=98%, differential pressure < 29.4 Pa/cm2. Color blue. Packed 50 pcs in carton in feeder form op. a'50pcs. 250,00
Part 37“A set of napkins with cutouts - reinforced
• 1 operating tape 9 x 50 cm
• 1 Mayo table napkin, reinforced 78 x 145 cm (reinforcement of the napkin 65x85cm), foil-PE sandblasted 60 μm blue, absorbent reinforcement - laminate 2 layer, PE+PP (polyethylene, polypropylene) foiled, waterproof, absorbent part polypropylene. Total weight 140 g/m2
75x148cm, reinforcement 65x85cm
• 4 hand towels
• 1 adhesive 75 x 90 cm (3-layer over the entire surface)
• 1 napkin with “U” cut 20 x 100 cm (3-layer in the patient dedicated part), with absorbent layer and conductor organizers 230 x 260 cm, absorbent patch 75 x 140 cm
• 1 glued large napkin 150 x 240 cm (3-layer in the dedicated part for the patient 75x240cm)
• 1 napkin per table for instrumentarium 150 x 190 cm foil - PE sandblasted 60 μm blue, absorbent reinforcement - laminate 2 layer, PE+PP (polyethylene, polypropylene) foiled, waterproof, in the absorbent part polypropylene. Total weight 140 g/m2 150x190cm, reinforcement 75x190
Material of 3 layer PE+PP+PP (film thickness 33μ) with a weight of 75 g/m2 in the basic part + absorbent patch with a weight of 80g/m2.
Wet/dry burst resistance in critical area 290/314 kPa
Fluid penetration resistance (absorbency) 167 cm H2O.
Absorption of fluid according to EN ISO 9073- 6:2003 = 990% On package 4 repositionable adhesive labels containing catalogue number, series, expiration date and manufacturer information for archiving data.
In a well-visible part of the packaging, a label shows the elements included in the set and their sizes.
On the set there should be a clear indication of the direction of the decomposition (arrow system), as well as the location of the location in the operating field (e.g., head, foot).
Packaging type TYVEC/Foil.
Packaged in cardboard intermediate packaging — dispenser with perforated one edge and transport carton (includes product label) — to ensure safety of transport and storage in operating block conditions.
Sterile product, packaged in a way that guarantees an aseptic manner of application of the contents of the package. The occupancy material must comply with the requirements of standard PN-EN 13795 1-3.
Servets with blunting edges ensure stability of occupancy and tightness in the presence of applied fluids and bodily fluids.
Occupancy servets shall not contain viscose and cellulose fibers.” pcs 100,00
Part 38“Universal set with a napkin for the Mayo table
• 1 operating tape 9 x 50 cm
• 1 Mayo table napkin, reinforced 78 x 145 cm (reinforcement of the napkin 65x85cm), foil-PE sandblasted 60 μm blue, absorbent reinforcement - laminate 2 layer, PE+PP (polyethylene, polypropylene) foiled, waterproof, absorbent part polypropylene. Total weight 140 g/m2
75x148cm, reinforcement 65x85cm
• 2 hand towels
• 2 glued napkins 75 x 90 cm
• 1 glued napkin medium 180 x 180 cm
• 1 glued large napkin 150 x 240 cm
• 1 napkin per table for instrumentarium 150 x 190 cm foil - PE sandblasted 60 μm blue, absorbent reinforcement - laminate 2 layer, PE+PP (polyethylene, polypropylene) foiled, waterproof, in the absorbent part polypropylene. Total weight 140 g/m2 150x190cm, reinforcement 75x190
Material of 2 layer PE+PP (film thickness 33μ) with a weight of 60 g/m2 in the basic part. Wet/dry burst resistance in critical area 168 kPa.
Fluid penetration resistance (absorbency) 165 cm H2O. Absorption of fluid according to EN ISO 9073- 6:2003 = 458% On pack 4 repositionable adhesive labels containing catalogue number, series, expiration date and manufacturer information for archiving data.
In a well-visible part of the packaging, a label shows the elements included in the set and their sizes.
On the set there should be a clear indication of the direction of the decomposition (arrow system), as well as the location of the location in the operating field (e.g., head, foot).
Packaging type TYVEC/Foil.
Packaged in cardboard intermediate packaging — dispenser with perforated one edge and transport carton (includes product label) — to ensure safety of transport and storage in operating block conditions.
Sterile product, packaged in a way that guarantees an aseptic manner of application of the contents of the package. The occupancy material must comply with the requirements of standard PN-EN 13795 1-3.
Servets with blunting edges ensure stability of occupancy and tightness in the presence of applied fluids and bodily fluids.
Occupancy servets shall not contain viscose and cellulose fibers.” pcs 700,00
Part 39“Universal set with absorbent patch with napkin for Mayo table
• 1 operating tape 9 x 50 cm
• 1 Mayo table napkin, reinforced 78 x 145 cm (reinforcement of the napkin 65x85cm), foil-PE sandblasted 60 μm blue, absorbent reinforcement - laminate 2 layer, PE+PP (polyethylene, polypropylene) foiled, waterproof, absorbent part polypropylene. Total weight 140 g/m2
75x148cm, reinforcement 65x85cm
• 4 hand towels — 100%
• 2 glued 2-layer napkins on the entire surface with additional absorbent patch and conductor organizers 75 x 90 cm, absorbent patch 15x50 cm
• 1 glued medium (2-layer over the entire surface) with additional absorbent patch and conductor organizers 180 x 180 cm, absorbent patch 15x50 cm
• 1 glued large napkin 150 x 240 cm (2-layer over the entire surface)
• 1 napkin per table for instrumentarium 150 x 190 cm foil - PE sandblasted 60 μm blue, absorbent reinforcement - laminate 2 layer, PE+PP (polyethylene, polypropylene) foiled, waterproof, in the absorbent part polypropylene. Total weight 140 g/m2 150x190cm, reinforcement 75x190
Material of 2 layer PE+PP (film thickness 33μ) with a weight of 60 g/m2 in the basic part + absorbent patch with a weight of 80g/m2.
Wet/dry burst resistance in critical area 168 kPa.
Fluid penetration resistance (absorbency) 165 cm H2O.
Absorption of fluid according to EN ISO 9073- 6:2003 = 990% On package 4 repositionable adhesive labels containing catalogue number, series, expiration date and manufacturer information for archiving data.
In a well-visible part of the packaging, a label shows the elements included in the set and their sizes.
On the set there should be a clear indication of the direction of the decomposition (arrow system), as well as the location of the location in the operating field (e.g., head, foot).
Packaging type TYVEC/Foil.
Packaged in cardboard intermediate packaging — dispenser with perforated one edge and transport carton (includes product label) — to ensure safety of transport and storage in operating block conditions.
Sterile product, packaged in a way that guarantees an aseptic manner of application of the contents of the package. The occupancy material must comply with the requirements of standard PN-EN 13795 1-3.
Servets with blunting edges ensure stability of occupancy and tightness in the presence of applied fluids and bodily fluids.
Occupancy servets shall not contain viscose and cellulose fibres.” pcs 200,00
Part 4“Hip kit
Set for hip surgery Composition of the set:
a) Surgical top with adhesive tape measuring 300x175 cm, reinforced in the critical zone (additional absorbent layer weighing 50g/m2) and equipped with conductor organizers 300x175cm - 1pc.
b) lower surgical service with dimensions 200x260 cm with “U” excision measuring 7x102 cm, strengthened (additional absorbent layer) in the critical zone 200x260cm - 2pcs.
c) surgical napkin 75x90cm - 1 pc
d) a napkin for a table 150x190cm - 1pcs.
e) limb cover 32x120cm - 1pc
f) two-layer viscous tape size 9x49cm - 2pcs
g) cellulosic absorbent towels size 18x25cm - 4pcs
h) Mayo table cover 79x145cm with absorbent layer 65x85cm, - 1pcs.
i) wrap a set of 150x190cm cover on an instrumental table -1 pc
Requirements:
— made of three-layer laminate with a weight of min 60g/m2, It is required that one of the layers of the material be PE film,
— dry/wet burst strength: 360/330 kPa in critical zone
— fluid penetration strength 820 cm H2O in the critical zone
Packaging paper-foil bag or foil with label in Polish with at least two stickers to be pasted in medical records as no. The product sterilized according to the standards required by law.
Quantity in pack 8 pcs” pcs. 9
Part of the 40thOperating film: sterile, stretchable low memory stretching, antistic, matte, anti-reflective, flexible, made of 0.025 mm polyester film, acrylic glue, large non-adhesive parts on 2 sides of film and safety paper with liner release marker used during application, individual paper-film packaging, additional paper in the package protecting the film from damage, double adhesive price tag for medical records with barcode containing series number, expiry date and catalogue number, medical device class IIa. CE certificate of notified body size 28cm x 41cm pcs 20,00
Part 41Sterile, breathable, antistic, matte, of polyester film of 0.0025 mm thick with acrylic adhesive containing iodor from which molecular iodine with bactericidal effect is released, large non-adhesive parts on 2 sides of the film, and safety paper with film end marking used during application, non-flammable (1st class of flammability), individual packaging of aluminium foil, additional paper wrapping sickened before damage, medical device class III, CE certificate of notified body, size 44 cm x 35 cm, viscous part size 34 cmx 35 cm roll 240,00
Part 42Kit for childbirth, composition: 113x90cm buttock napkin made of non-woven double-layer laminate made of polypropylene non-woven and polyethylene polypropylene film, blue color, absorbency 570%, absorbency 27,96%, longitudinal tear strength 29.72N, film has antistatic properties, laminate does not cause irritation, sensitization, is not cytotosical, 1st class flammability acc. to 16 CFR 1610 (test method PN-EN ISO 6941), non-woven compress napkin 80x60cm absorbent and delicate - 1 pc, compress non-woven napkins 20x25cm absorbent and delicate - 6 ptive , pulp absorbent pulp absorbent primer 60x60cm - 1 pc, pulp absorbent primer 90x60cm size - 1 pc The whole sets wrapped in a 150x90cm napkin made of non-woven three-layer laminate made of non-woven viscose woven, polyethylene polypropylene film and polypropylene non-woven film with a weight of 73 g/m2, blue color, absorbency 824%, absorbency 48,17%, taxidermy strength dry 108 kPa, wet push strength 95 kPa, liquid penetration resistance 191 cmH2O, film has antistatic properties, laminate does not cause irritation, sensitization is not cytotosical, 1st flammability class acc. 16 CFR 1610 (test method PN-EN ISO 6941), (data card required technical, confirming the above parameters). Paper and foil bag type wrapper 800 pcs
Part 43Kit for newborn, composition of the set: pulp primer with pulp backfoiled size 60x60cm - 1 pc, compress non-woven compress size 60x80cm - 2 pcs, cap for newborn 10x12cm - 1 pc, flannel blanket 160x75cm - 1 pc. The set contains a positive opinion of the Institute for Child Health Center (supporting document required). Packaged in a paper-foil bag with special welding along the shorter side with an obtuse V-shape - the so-called chevron, which further facilitates dust-free opening of the package, in the bag there are cut cuts for the thumb to capture the film with your thumb for easier opening. packaging.Paper and foil bag with large readable double-perforated label with 2 TAGs on the package (information on tags: expiration date, index, LOT number, barcode). After the 2 tags are peeled off, the main label remains on the part of the package. Required document in the form of a validation report of the sterilization process. Triple packaging system, soft blister packaging, internal cardboard (dispenser), external carton transport. 800 pcs.
Part of the 44thCatheterization kit, composition of the set: cellulose-polyethylene subfolded non-woven woven napkin 50cmx60cm weighing 42 g/m2 — 1 pcs, cellulose-polyethylene subfoil napkin, 50cmx60cm diameter hole, 42g/m2 - 1pc, latex gloves size M - 2 pcs, tupfer ball 17N 20cmx20cm - 6 pcs, plastic tweezers - 1 pc The whole in a package of hard blister type with 3 partitions. The set includes a large, legible, bipartite, triple-perforated barcode label with two TAG type labels, containing: index, series number, LOT, for keeping medical records. After the tags are peeled off, the main label remains on the paper part of the packaging. 15 TEX required confirmation document (not statement). pcs 500
Part of the 45thLumbar insertion assembly, composition of the set: cellulosic and polyethylene foil napkin with a weight of 42 g/m2 in size 45x75cm - 1 pc, non-woven polypropylene double-layer napkin with a weight of 56 g/m2 in size 50x60cm with a hole of 10cm diameter with an adhesive around the hole and! 2 Adhesives in the upper corners of the napkin — 1 pc, non-woven compresses 30 g/m2 4W 7.5x7.5cm — 10 pcs, syringe 3ml — 1 pc, syringe 5ml type Luer Lock — 1 pc, needle 1.2x40mm — 1 pc, needle 0.5x25mm — 1 pc, isle dressing with absorbent part to protect puncture places 5x7,2 cm — 1 pc. The whole in a package of hard blister type with 3 partitions. The set includes a large, legible, bipartite, triple-perforated barcode label with two TAG type labels, containing: index, series number, LOT, for keeping medical records. After the TAGs are peeled off, the main label remains on the paper part of the packaging. Required document in the form of a validation report of the sterilization process. Dressing material made of yarn min. 15 TEX required confirmation document (not statement). pcs 500
Part of the 46thDressing change assemblies, set: wrap bag for waste 240x270mm — 1 pcs, latex gloves size M — 2 pcs, non-woven compresses 30g 4W 7.5x7.5 cm — 2 pcs, tupfer ball 17N 20x20 cm — 6 pcs, plastic tweezers green — 1 pc, tweezers plastic blue ska - 1 pcs, blade no. 11 — 1 pc The whole in a package of hard blister type with 3 partitions. The set includes a large, legible, bipartite, triple-perforated barcode label with two TAG type labels, containing: index, series number, LOT, for keeping medical records. Required document in the form of a validation report of the sterilization process. Dressing material made of yarn min. 15 TEX required document confirming pcs 500
Part of the 47thNon-alloy napkins made of non-woven compress 40g, pack A'50 pieces, white, size 80x60cm, absorbent. Packed in transparent foil. Op100
Operating table covers made of laminate polyethylene polypropylene film and non-woven polypropylene fabric with a total weight of 27 g/m2, absorbency minimum 80 cm H2O, size 220x90cm, white color, non-alum in pack 100 pcs. op 20
Part of the 48thKit for removal of clamps for umbilical cord, stingy set: tool for cutting clamps - 1 pcs, gas compresses 17N 8W size 7.5 x 7.5cm - 3 pcs. All in a package of hard 1-chamber blister type. The set includes a large, legible, bipartite, triple-perforated barcode label with two TAG type labels, containing: index, series number, LOT, for keeping medical records. After the tags are peeled off, the main label remains on the paper part of the packaging. 15 TEX proof document required (not statement). pcs 200
Part of the 49thBarren primer for use as additional protection. The underside layer is a white non-slip insulating film with a print. In the absorbent cartridge there is shredded cellulose, additionally covered with tissue paper. The top layer is non-woven. Size 60x60cm, primer weight min. 65g, absorbency not less than 1400g according to ISO 11948-1. Paper and film bag type. The packaging includes a large, readable bipartite, triple-perforated barcode label with two TAG type labels. After the TAGs are peeled off, the main label remains on part of the package. Required document in the form of a validation report of the sterilization process. pcs 800
Barren primer for use as additional protection. The underside layer is a white non-slip insulating film with a print. In the absorbent cartridge there is shredded cellulose, additionally covered with tissue paper. The top layer is non-woven. Size 60x90cm, primer weight min. 95g, absorbency not less than 2000g ISO 11948-1. Paper and foil bag type pcs 500
Part of the 5th“Hip surgery kit (DHS):
— 1 pc. surgical service for intramedullary anastomoses measuring 240x290
Cm, integrated with leg legs, equipped with two symmetrically positioned
Holes measuring 15x45 cm
Filled with surgical film. Strengthening in the critical zone with dimensions
75x210 cm
— 1 pcs adhesive tape
— 2 pieces of absorbent towels
- 1 piece self-adhesive single-compartment pocket with 30 x 50 cm stiffer
- 1 piece MAYO table cover 79 x 145 cm
- 1 piece of napkin per table - (wrap set) 150 x 200 cm
The kit must meet the requirements high according to PN EN 13795 1-3 at
Simultaneous insolvency in the critical zone of the main servet on
Horizontal min. 340 cm H2O and taxidermy strength in the critical zone
Min. 150 kPa
Main servet made of laminate min. double layer with weight min 62
G/m2 in the less critical zone, reinforced in the critical zone with laminate
Min. double layer viscose weight of min. 83 g/m2
Quantity in package 3 pcs.” pc.67
Part of the 50thShoulder cover “C”, transparent, made of foil, size (33÷112) x56cm, beret type with rubber band. pcs 2 500
Part of the 51stNon-woven sterile fabric 130 cm x 80 cm packed A'1 - 100% polypropylene non-woven weight 35 g/m2, blue color, vapor permeability 3579 g/m2x24h,, liquid penetration resistance 31 cmH2O, dry taxidermy strength 124 kPa, taxidermy strength wet 115 kPa, wiping of longitudinal splitting 32,74N, wiping on transverse splitting 43.34N. Packed in a paper-foil bag with a special welding along the shorter side with an obtuse V-shape - the so-called chevron, which further facilitates dust-free opening of the package, in the bag there are cut cutouts for the thumb to capture the film with your thumb for easier to open the film easier to make it easier to open the package. opening package.Paper and foil bag with large readable double perforated label with 2 TAGs on the package (information on tags: expiration date, index, LOT number, barcode). After peeling off 2 tags, the main label remains on the packaging part. pcs 200
Part 52Barren servet, size 130x90cm, foiled on a whole surface of non-woven double-layer laminate made of polypropylene non-woven and polyethylene polypropylene film with a weight of 43 g/m2, blue color, absorbency 617%, absorbency 16,91%, tearing longitudinal 15.57N, transverse tear wiping 23,29N, dry taxidermy strength 218 kPa, wet push strength 130 kPa, liquid penetration resistance 182 cmH2O, film has antistatic properties, laminate does not cause irritation, sensitization is not cytotosical (required technical data card, confirming the above parameters). The cover packed in a paper-foil bag with special welding along the shorter side with an obtuse V-shape - the so-called chevron, which further facilitates dust-free opening of the package, there are cut cuts for the thumb in the bag to capture the film with your thumb for easier opening packaging.Paper and foil bag with large readable double-perforated label with 2 TAGs on the package (information on tags: expiration date, index, LOT number, barcode). After ungluing 2 tags, the main label remains on the packaging part. pcs 800
Part 53Lower limb cover, barren, 80x45cm packed A'1 with a size of 80x45cm made of non-woven double-layer laminate made of polypropylene non-woven and polyethylene polypropylene film with a weight of 43 g/m2, blue color, absorbency 617%, absorbency 16,91%, wiping 15.57N longitudinal tear, 23,29N transverse tearing strength, 218 kPa dry taxidermy strength, 130 kPa wet taxidermy, liquid penetration resistance 182 cmH2O, film has antistatic properties, laminate does not cause irritation, sensitization does not is cytotosical (technical data card required, confirming the above parameters). The cover packed in a paper-foil bag with special welding along the shorter side with an obtuse V-shape - the so-called chevron, which further facilitates dust-free opening of the package, there are cut cuts for the thumb in the bag to capture the film with your thumb for easier opening packaging.Paper and foil bag with large readable double-perforated label with 2 TAGs on the package (information on tags: expiration date, index, LOT number, barcode). After peeling off 2 tags, the main label remains on the packaging part. pcs 200
Part 54150x180cm with adhesive made over the entire surface of non-woven double-layer laminate made of polypropylene non-woven and polyethylene polypropylene film 56 g/m2, blue color, absorbency 570%, absorbency 27,96%, longitudinal tear wiping 29,72N, transverse tear strength 40.33N, dry taxidermy strength 150 kPa, wet push strength 150 kPa, liquid penetration resistance 250 cmH2O, film has antistatic properties, laminate does not cause irritation, sensitization, is not cytotosical, I class flammability according to 16 CFR 1610 (test method PN-EN ISO 6941), (technical data card required, confirming the above parameters). Packed in a paper-foil bag with a special welding along the shorter side with an obtuse V-shape - the so-called chevron, which further facilitates dust-free opening of the package, in the bag there are cut cutouts for the thumb to capture the film with your thumb for easier to open the film easier to make it easier to open the package. opening package.Paper and foil bag with large readable double perforated label with 2 TAGs on the package (information on tags: expiration date, index, LOT number, barcode). After peeling off 2 tags, the main label remains on the packaging part. pcs 500
Part 55Promoter for wires, barren, with adhesive, .size 15 x 10cm with 3 holes. Packaged in a paper-foil bag with special welding along the shorter side with an obtuse V-shape - the so-called chevron, which further facilitates dust-free opening of the package, there are cut cutouts for the thumb in the bag to capture the film with your thumb for easier opening packaging.Paper and foil bag with large readable double-perforated label with 2 TAGs on the package (information on tags: expiration date, index, LOT number, barcode). After peeling off 2 tags, the main label remains on the packaging part. 100 pcs
Part 56Non-reinforced surgical apron made of non-woven SMS weighing 35g/m2, sleeve finished with non-dusting polyester cuff min. 7cm long, reglan sleeves, ultrasonic seams, Velcro neck fastening, carton to support troks allowing for tying apron first on “dirty” and then on “purely”, folded in a “book folded” manner facilitating the independent foundation of the apron by the surgeon in an aseptic manner, sterilization with water vapor. Liquid penetration resistance min 36.9 cm H20, vapor permeability at 4389 g/m2/24h. Longitudinal tear strength 34.4N, transverse tear strength 20.5N. The paper-foil bag package contains a large, readable, bipartite, triple-perforated barcode label with two TAG labels, containing: index, series number, LOT, for keeping medical records. After removing from the pack, the stamp with the size marking, the type of apron, the protection level and EN 13795 standard, the main label remains on the package after the tags are peeled off. Required document in the form of a validation report of the sterilization process. Apron sizes, size M: apron length 115cm from top point of shoulder, sleeve length with no welt 75cm, width at bottom of apron 150cm after unfolding, size L apron length 125cm from top point of shoulder, length of sleeve without welt 82cm, width at bottom of apron 160 cm when unfolded, size XL apron length 140cm from the highest point of the shoulder, length of sleeve without a welt 84cm, width at bottom of the apron 165cm after unfolding, size XXL apron length 155cm from the highest point of the shoulder, length of sleeve without a welt 86cm, width at the bottom of the apron 170 cm when laid out. Apron packed extra in crepe paper + towels made of non-woven compress 20x40cm. pcs 1 000
Barren surgical apron reinforced, designed for high-risk procedures made of non-woven SMS weighing 35g/m2 in the less critical zone, in the critical sleeve zone, the front of the apron is further reinforced with non-foiled non-woven weighing 40 g/m2, apron reinforcements are located on the outer part of the apron, the sleeve finished with a non-dusting polyester cuff length of min. 7cm, reglan sleeves, seams sewn by ultrasonic method, fastening under the neck with velcro, carton to support the trok allowing you to tie the apron first “dirty” and then “clean”, folded in a “book folded” manner that facilitates the self-establishment of the apron by the surgeon in an aseptic manner, vapor sterilization. Liquid penetration resistance in the critical zone 203.3 cm H20, less critical zone 32 cmH2O, vapor permeability at 4495 g/m2/24h. Longitudinal tear strength 34.5N, transverse tear strength 20.5N, longitudinal tear strength 36.8N, transverse splitting strength 26.1. The paper-foil bag package contains a large, readable, bipartite, triple-perforated barcode label with two TAG labels, containing: index, series number, LOT, for keeping medical records. After removing from the pack, the stamp with the size marking, the type of apron, the protection level and EN 13795 standard, the main label remains on the package after the tags are peeled off. Required document in the form of a validation report of the sterilization process. Apron sizes, size M: apron length 115cm from top point of shoulder, sleeve length with no welt 75cm, width at bottom of apron 150cm after unfolding, size L apron length 125cm from top point of shoulder, length of sleeve without welt 82cm, width at bottom of apron 160 cm when unfolded, size XL apron length 140cm from the highest point of the shoulder, length of sleeve without a welt 84cm, width
Part 57Universal kit made of non-woven double-layer laminate made of polypropylene non-woven and polyethylene polypropylene film 56 g/m2, blue color, absorbency 570%, absorbency 27,96%, longitudinal tear strength 29,72N, strength to transverse splitting 40,33N, dry taxidermy strength 150 kPa, wet push strength 150 kPa, liquid penetration resistance 250 cmH2O, film has antistatic properties, laminate does not cause irritation, sensitization, is not cytotosical, I flammability class according to 16 CFR 1610 (test method PN-EN ISO 6941), (technical data card required, confirming the above parameters). The whole set is wrapped in a napkin for a 150x190cm instrumentarium table made of polyethylene film and an absorbent layer with a width of 66cm along the entire length of the napkin. Surface masses of individual layers of napkin for the instrumentarium table: non-woven 35 g/m2, film 47 g/m2, adhesive 2 g/m2. The absorbent layer of the napkin for the instrumentarium table is 400%, water barrier above 100 cmH2O. Mayo table cover telescopic folding inside, marking with a pictogram sticker is facilitated by quick application 145x80cm in size made of polyethylene film and non-woven absorbent layer, non-woven weight 24 g/m2, film thickness 45μm - sandblasted film, strength dry and wet stuffing ≥ 40 kPa, water barrier ≥ 30 cm H2O, hand wiping napkins made of non-woven compress 40g size 20x40cm — 2 pcs Packaging of soft paper-foil blister type. The set includes a large, legible perforated bar code label and with four TAG type labels, containing: index, series number, LOT, for keeping medical records. After the TAGs are peeled off, the main label remains on part of the package. Required document in the form of a validation report of the sterilization process. Triple packaging system, soft blister packaging, internal cardboard (dispenser), external transport carton. Composition of the set፦ clingboard 240x150cm - 1 pcs - sticky napkin 180x170cm - 1 pcs - clingboard 90x75cm - 2 pcs - Medical tape 50x9cm - 1 pc - Mayo table napkin - 1 pc - Instrumentarium table napkins - 1 pc. pcs 600
Part 58Physiological delivery kit, expanded in composition: tooltable napkin made of polypropylene non-woven and polyethylene polypropylene film 56 g/m2, blue color, absorbency 570%, absorbency 27,96%, longitudinal tear wiping 29,72N, 40,33N transverse tearing strength, 150 kPa dry taxidermy strength, 150 kPa wet push strength, 150 kPa, liquid penetration resistance 250 cmH2O, film has antistatic properties, laminate does not cause irritation, sensitization is not cytotosical, 1st class flammability according to 16 CFR 1610 (test method PN-EN ISO 6941), (technical data card required, confirming the above parameters) size 150x90cm — 1 pc, lower limb cover made of polypropylene non-woven weight 35 g/m2 120x80cm — 1 pc, tupfery balls 17N 30x30x30xcm — 5 pcs, non-woven compresses 40 g/m2 10x20cm — 5 pcs, non-woven compresses 40 g/m2 4W 7.5x7.5cm — 10 pcs, metal scissors for cutting umbilical cord length 12.5cm — 1 pc, umbilical clamps — 2 pcs, flannel blanket for baby 160x75cm — 1 pc, cap for newborn — 1 Seni Soft pulp primer 90x60cm — 1 pc compress non-woven napkin 40 g/m2 80x60cm — 1 pc, crotch shade scissors metal 18cm — 1 pc, plastic corcang 24cm — 1 pc, cardboard kidney per placenta - 1 pc, powderless latex gloves size M — pair, centimeter for measuring newborn. Entire packaged in a TYVEK package with a large readable double-perforated 2xTAG label for easy medical record keeping. TYVEK type packaging. The set includes a large, legible, bipartite, triple-perforated barcode label with two TAG type labels, containing: index, series number, LOT, for keeping medical records. After the TAGs are peeled off, the main label remains on the paper part of the packaging. Required document in the form of a validation report of the sterilization process. 100 pcs
Part 59Caesarean section kit made of non-woven double-layer laminate made of polypropylene non-woven and polyethylene polypropylene film 56 g/m2, blue color, absorbency 570%, absorbency 27,96%, longitudinal tear strength 29,72N, transverse tear strength 40.33N, dry taxidermy strength 150 kPa, wet push strength 150 kPa, liquid penetration resistance 250 cmH2O, film has antistatic properties, laminate does not cause irritation, allergic, is not cytotosical, 1st class flammability according to 16 CFR 1610 (test method PN-EN ISO 6941), (technical data card required, confirming the above parameters). The whole set is wrapped in a napkin for a 150x190cm instrumentarium table made of polyethylene film and an absorbent layer with a width of 66cm along the entire length of the napkin. Surface masses of individual layers of napkin for the instrumentarium table: non-woven 35 g/m2, film 47 g/m2, adhesive 2 g/m2. The absorbent layer of the napkin for the instrumentarium table is 400%, water barrier above 100 cmH2O. Mayo table cover telescopic folding inside, marking with a pictogram sticker is facilitated by quick application 145x80cm in size made of polyethylene film and non-woven absorbent layer, non-woven weight 24 g/m2, film thickness 45μm - sandblasted film, strength dry and wet stuffing ≥ 40 kPa, water barrier ≥ 30 cm H2O, hand wiping napkins made of compress nonwoven 40g size 20x40cm — 2 pcs, set composition: 320x180cm main napkin with hole and bag around hole, hole filled with surgical film with notch in pear shape 10x15cm - 1 pc, non-woven napkin weighing 35 g/m2 size 130x80cm - 1 pc, duster napkin with weight min. 43 g/m2 size 130x90cm - 1 pc, Mayo table napkin - 1 pc, table napkin for instrumentarium - 1 pc, absorbent non-woven compress with weight min. 40 g/m2 size 80x60cm - 1 pc The whole packaged in a paper-foil bag type. The set includes a large, legible, perforated barcode label with four TAG labels, containing: index, series number, LOT, for keeping medical records. After the TAGs are peeled off, the main label remains on part of the package. Required document in the form of a report validation of the sterilization process. pcs 300
Part of the 6th“Universal Set LIGHT 790500
Minimum composition:
a) 1x top napkin with adhesive tape 240x150 cm
b) 2x side napkins with adhesive tape 90x75 cm
c) 1x bottom with adhesive tape 175x175 cm
d) 1x adhesive tape 9x49 cm
e) 4x absorbent towels 18x25 cm
f) 1x table cover MAYO 79x145 cm
g) 1x table napkin - (wrap set) 140x190 cm
It is required that the napkins (a, b, c):
— were made of double-layer laminate (critical zone)
— laminate weight > 60 g/m2 (critical zone)
— liquid penetration resistance (hydrostatic pressure) over the entire surface of the napkin >99cm H2O
— one of the layers is to be a PE film
— dry taxidermy strength (critical zone) > 87 kPa
Quantity in packaging 14 pcs” pcs.100
Part 60Hip operation kit made of non-woven three-layer laminate made of non-woven viscose woven, polyethylene polypropylene film and polypropylene non-woven fabric with a weight of 73 g/m2, blue color, absorbency 824%, absorbency 48,17%, dry taxidermy strength 108 kPa, wet push strength 95 kPa, liquid penetration resistance 191 cmH2O, film has antistatic properties, laminate does not cause irritation, sensitization is not cytotosical, 1st flammability class acc. 16 CFR 1610 (test method PN-EN ISO 6941), (data card required technical, confirming the above parameters). The whole set is wrapped in a napkin for a 150x190cm instrumentarium table made of polyethylene film and an absorbent layer with a width of 66cm along the entire length of the napkin. Surface masses of individual layers of napkin for the instrumentarium table: non-woven 35 g/m2, film 47 g/m2, adhesive 2 g/m2. The absorbent layer of the napkin for the instrumentarium table is 400%, water barrier above 100 cmH2O. Mayo table cover telescopic folding inside, marking with a pictogram sticker is facilitated by quick application 145x80cm in size made of polyethylene film and non-woven absorbent layer, non-woven weight 24 g/m2, film thickness 45μm - sandblasted film, strength dry and wet stuffing ≥ 40 kPa, water barrier ≥ 30 cm H2O, hand wiping napkins made of compress nonwoven 40g size 20x40cm — 2 pcs, composition of set: 260x240cm main napkin with “U” cut size 100x20cm with adhesive - 1 pcs, Cover 240x150cm with cutout “U” size 63x7cm with adhesive - 1 pc, lower limb cover size 120x37cm, medical tape 50x9cm - 2 pcs, wiring organizer 10x15cm with 3 holes in diameter 2cm - 1 pc, Mayo servo - 1 pc for the instrumentarium table - 1 pc. The whole packaged in a paper-foil bag type. The set includes a large, legible, perforated barcode label with four TAG labels, containing: index, series number, LOT, for keeping medical records. After the TAGs are peeled off, the main label remains on part of the package. Required document in the form of a validation report of the sterilization process. Triple packaging system, paper-foil bag type packaging, internal cardboard (dispenser), external carton transport. pcs 300
Part 61Knee arthroscopy kit made of non-woven double-layer laminate made of polypropylene non-woven and polyethylene polypropylene film 56 g/m2, blue color, absorbency 570%, absorbency 27,96%, longitudinal tear strength 29,72N, transverse tear strength 40.33N, dry taxidermy strength 150 kPa, wet push strength 150 kPa, liquid penetration resistance 250 cmH2O, film has antistatic properties, laminate does not cause irritation, allergic, is not cytotosical, 1st class flammability according to 16 CFR 1610 (test method PN-EN ISO 6941), (technical data card required, confirming the above parameters). The whole set is wrapped in a napkin for a 150x190cm instrumentarium table made of polyethylene film and an absorbent layer with a width of 66cm along the entire length of the napkin. Surface masses of individual layers of napkin for the instrumentarium table: non-woven 35 g/m2, film 47 g/m2, adhesive 2 g/m2. The absorbent layer of the napkin for the instrumentarium table is 400%, water barrier above 100 cmH2O. Mayo table cover telescopic folding inside, marking with a pictogram sticker is facilitated by quick application 145x80cm in size made of polyethylene film and non-woven absorbent layer, non-woven weight 24 g/m2, film thickness 45μm - sandblasted film, strength dry and wet stuffing ≥ 40 kPa, water barrier ≥ 30 cm H2O, hand wiping napkins made of compress non-woven 40g size 20x40cm — 2 pcs, set composition: 320x240cm main napkin with 6cm diameter hole with liquid collection bag - 1 pc, table napkin Mayo - 1 pc, Instrumentary table napkin - 1 pc, lower limb cover 75x37cm - 1 pcs, medical tape 50x9cm - 2 pcs The whole packaged in a paper-foil bag type. The set includes a large, legible, perforated barcode label with four TAG labels, containing: index, series number, LOT, for keeping medical records. After the TAGs are peeled off, the main label remains on part of the package. Required document in the form of a validation report of the sterilization process. Triple packaging system, paper-foil bag type packaging, internal cardboard (dispenser), external carton transport. pcs 150
Part 62Kit for knee operation, made of non-woven three-layer laminate made of non-woven viscose woven, polyethylene polypropylene film and non-woven polypropylene fabric with a weight of 73 g/m2, blue color, absorbency 824%, absorbency of 48,17%, taxidermy strength dry 108 kPa, wet push strength 95 kPa, liquid penetration resistance 191 cmH2O, film has antistatic properties, laminate does not cause irritation, sensitization is not cytotosical, 1st flammability class acc. 16 CFR 1610 (test method PN-EN ISO 6941), (data card required technical, confirming the above parameters). The whole set is wrapped in a napkin for a 150x190cm instrumentarium table made of polyethylene film and an absorbent layer with a width of 66cm along the entire length of the napkin. Surface masses of individual layers of napkin for the instrumentarium table: non-woven 35 g/m2, film 47 g/m2, adhesive 2 g/m2. The absorbent layer of the napkin for the instrumentarium table is 400%, water barrier above 100 cmH2O. Mayo table cover telescopic folding inside, marking with a pictogram sticker is facilitated by quick application 145x80cm in size made of polyethylene film and non-woven absorbent layer, non-woven weight 24 g/m2, film thickness 45μm - sandblasted film, strength dry and wet stuffing ≥ 40 kPa, water barrier ≥ 30 cm H2O, hand wiping napkins made of compress nonwoven 40g size 20x40cm — 2 pcs, composition of set: 320x240cm main napkin with flexible hole diameter 6cm - 1 pc, napkin with adhesive 150x180cm - 1 pcs, cover for lower limb size 75x37cm, medical tape 50x9cm - 2 pcs, organizer for wires 10x15cm with 3 holes 2cm diameter - 1 pc, Mayo napkin - 1 pc, table napkin for instrumentarium - 1 pc. The whole packaged in a paper-foil bag type. The set includes a large, legible, perforated barcode label with four TAG labels, containing: index, series number, LOT, for keeping medical records. After the TAGs are peeled off, the main label remains on part of the package. Required document in the form of a validation report of the sterilization process. Triple packaging system, paper-foil bag type packaging, internal cardboard (dispenser), external carton transport. pcs 300
Part 63113x90cm buttock cover with liquid bag made of non-woven double-layer laminate made of polypropylene non-woven and polyethylene-polypropylene film 56 g/m2, blue color, absorbency 570%, absorbency 27,96%, strength longitudinal tear 29,72N, transverse tear strength 40.33N, dry taxidermy strength 150 kPa, wet taxidermy strength 150 kPa, liquid penetration resistance 250 cmH2O, film has antistatic properties, laminate does not cause irritation, sensitization, no is cytotosical, I flammability class according to 16 CFR 1610 (test method PN-EN ISO 6941), (technical data card required, confirming the above parameters). Packed in a paper-foil bag with a special welding along the shorter side with an obtuse V-shape - the so-called chevron, which further facilitates dust-free opening of the package, in the bag there are cut cutouts for the thumb to capture the film with your thumb for easier to open the film easier to make it easier to open the package. opening package.Paper and foil bag with large readable double perforated label with 2 TAGs on the package (information on tags: expiration date, index, LOT number, barcode). After peeling off 2 tags, the main label remains on the packaging part. pcs 300
Part 64Kit for gynecological operations made of non-woven double-layer laminate made of polypropylene non-woven and polyethylene polypropylene film 56 g/m2, blue color, absorbency 570%, absorbency 27,96%, longitudinal tear strength 29,72N, transverse tear strength 40.33N, dry taxidermy strength 150 kPa, wet push strength 150 kPa, liquid penetration resistance 250 cmH2O, film has antistatic properties, laminate does not cause irritation, allergic, is not cytotosical, 1st class flammability according to 16 CFR 1610 (test method PN-EN ISO 6941), (technical data card required, confirming the above parameters). The whole set is wrapped in a napkin for a 150x190cm instrumentarium table made of polyethylene film and an absorbent layer with a width of 66cm along the entire length of the napkin. Surface masses of individual layers of napkin for the instrumentarium table: non-woven 35 g/m2, film 47 g/m2, adhesive 2 g/m2. The absorbent layer of the napkin for the instrumentarium table is 400%, water barrier above 100 cmH2O. Mayo table cover telescopic folding inside, marking with a pictogram sticker is facilitated by quick application 145x80cm in size made of polyethylene film and non-woven absorbent layer, non-woven weight 24 g/m2, film thickness 45μm - sandblasted film, strength dry and wet stuffing ≥ 40 kPa, water barrier ≥ 30 cm H2O, hand wiping napkins made of non-woven compress 40g size 20x40cm — 4 pcs, set composition: 245x180cm main napkin with integrated leg and 10x15cm hole in the lower part Adhesive - 1 piece, napkin under the buttocks 90x75cm - 1 pc, medical tape 50x9cm - 2 pcs, Mayo napkin - 1 pc, table napkin for instrumentarium - 1 pc. The whole packaged in a paper-foil bag type. The set includes a large, legible, perforated barcode label with four TAG labels, containing: index, series number, LOT, for keeping medical records. After the TAGs are peeled off, the main label remains on part of the package. Required document in the form of a validation report of the sterilization process. Triple packaging system, paper-foil bag type packaging, internal cardboard (dispenser), external carton transport. pcs 200
Part 65Syringe 2 ml, two-piece with Luer tip, having double piston fall out protection, piston in green colour, not having stenches on the section from the end of the piston protruding outside the cylinder to the middle of the piston found in the cylinder, the manufacturer's logo and the trade name of the syringe on the cylinder, expanded scale to 3 ml. Packaging 100 pcs. pack 1 500 6,05 zł
5 ml syringe, two-piece with Luer tip, having double piston prolapse protection, piston in green colour, not having constrictions on the section from the end of the piston protruding outside the cylinder to the middle of the piston found in the cylinder, the manufacturer's logo and the trade name of the syringe on the cylinder, expanded scale to 6 ml. Packaging 100 pcs. pack 1 200 9,68 zł
10 ml syringe, two-piece with Luer tip, having a double piston fall out protection, a piston in green colour, having no constrictions on the section from the end of the piston protruding outside the cylinder to the mid-piston found in the cylinder, the manufacturer's logo and trade name syringe on the cylinder, expanded scale to 12 ml. Packaging 100 pcs. pack 1 500 15,73 zł
20 ml syringe, two-piece with Luer tip, having a double piston fall out protection, a piston in green colour, having no constrictions on the section from the end of the piston protruding outside the cylinder to the mid-piston found in the cylinder, the manufacturer's logo and trade name syringe on the cylinder, expanded scale to 24 ml. Packaging 100 pcs. pack 1 900 18,15 zł
Tuberculin syringe with needle 0.4-0.45 x 12-16 mm, 1 ml. Pack 100 pcs. pack 80 20,57 zł
Insulin syringe with needle 0.4 x 13-16 mm, 1 ml. Packaging 100 pcs. pack 50 20,57 zł
3-piece syringe for infusion pumps 50-60 ml, equipped with double measuring scale and double piston seal 6 000 0,65 zł
3-piece syringe for photosensitive drugs for infusion pumps 50-60 ml, equipped with double measuring scale and double piston seal. Packaging 100 pcs. pack 59 112,53 zł
Janette type syringe with 100 ml LUER controller, equipped with double measuring scale, two additional Luer couplers and a double piston seal. Packaging 100 pcs. pack 200 165,77 zł
Disposable injection needle 0.45-0.9, sterile, made of stainless steel, blade coated with silicone. Packaging 100 pcs. pack 2,000 3.99 zł
1.1-1,2 disposable injection needle, sterile, made of stainless steel, silicone coated blade, available in two types of blade (lengthened and shortened). Packaging 100 pcs. pack 2,000 4.48 zł
Needle for safe drug extraction from vials protected by a rubber stopper 1.2 with a side hole. Packaging 100 pcs. pack 400 8,35 zł
Infusion fluid shunting apparatus, a drip chamber made of PP min. 60 mm long in transparent part, whole phthalate-free (information on the unit packaging), dual-faceted needle made of ABS reinforced with fiberglass, roller clamp equipped with Drain holder and additional space for securing the needle after use placed on the side of the clamper, on the roller clamper, packaging foil paper, sterile. Packager= 200 pcs. pack 300 78,65 zł
Blood transfusion apparatus, PVC free drip chamber, whole phthalate-free (information on the unit package), roll clamp equipped with a drain holder and additional space for securing the needle after use placed on the clamper side, manufacturer's name on roller clamper, packaging foil paper, sterile pcs 3 000 0.85 zł
Cameras for rapid shunting of blood and blood preparations packaging film — paper, phthalate-free (except pump), cylinder-shaped pump 28 mm diameter and 12 cm long, equipped with two ball valves. pcs 500 8.11 PLN
Extensions for infusion pumps 150-200 cm without phthalate content (available at both bottom
Part 66Absorbing calcium sulfate to complement dead-space filling therapy, used for local treatment of infection in soft tissues, bone and marrow 10cc - type Stimulan Rapid Cure, pcs. 60
Part 67Absorbing calcium sulfate to supplement dead-space filling therapy, used for local treatment of infection in soft tissues, bone and marrow 20cc - type Stimulan Rapid Cure, pcs. 2
Part 68Sterile stasis for orthopedic procedures 40 yellow type Hemaclear pcs. 20
Sterile stasis for orthopedic procedures Hemaclear 60 brown type Hemaclear pcs. 150
Sterile stasis for orthopedic procedures 90 black - white type Hemaclear pcs. 30
Part 69Chest drainage kit, single sterile, four-chamber or three-chamber, with mechanical regulator (suction force control knob) for constant monitoring of intrapulmonary pressure, having needle-free valve ventricular ports of approx. 2200 ml, having a special secured needle port for retrieving freshly drained test fluid. pcs 30
Part of the 7th“LIGHT set with U cutout napkin
Minimum composition:
(a) 1x Surgical Top with Adhesive Tape —Anaesthesiological Screen 240x150cm
b) 1x lower surgical service 200x250cm with self-adhesive cut U 20x100cm
c) 4x absorbent towels 18x25cm
d) 1x table napkin — (wrap set) 140x190cm
It is required that the napkins (a, b):
— were made of double-layer laminate (critical zone)
— laminate weight > 60 g/m2 (critical zone)
— liquid penetration resistance (hydrostatic pressure) over the entire surface of the napkin >99cm H2O
— one of the layers is to be a PE film
— dry taxidermy strength (critical zone) > 87 kPa
Quantity in package 16 pcs.200
Part 70Trocar catheter with guide with funnel cap for direct connection to closed drainage system, sterile, packaged in plastic tube. pcs 20
Part 71Biochemical tubes type serum 2-3 ml 100000 0.44
Biochemical tubes type serum 4-5 ml 33000 0.44 pcs.
Biochemical tubes type serum 7-8 ml 11000 0.45
KEDTA hematological test tubes 2-3 ml 80000 0.44
Hematological test tubes K3EDTA 1-1.5 ml diameter 7-8mm pcs 3000 0.58
Coagulological test tubes with citrate 1-1.5 ml diameter 7-8mm pcs. 3600 0.58
Coagulological test tubes with citrate 3-4 ml pcs. 45000 0,46
Tubes for glucose indications 1-1,5 ml diameter 7-8mm pcs. 6000 0.56
System for testing OB. 2-3 ml (test tube and pipette). Indication of the test by linear method 7000 1.11
Tubes for determination of OB. 3-4 ml. pcs. 11000 0.80
Tube-syringe of 2-3 ml containing magnesium ions for the diagnosis of pseudotrhombocytopenia.
Syringes for gasometry 2 ml with applied sterile vent filter, packaged individually. 13000 1.38
Biochemical tubes type serum 0.2 ml with capillary pcs 20000 0.56
Hematological test tubes K3EDTA 0.2 ml with capillary pc 14000 0,56
Tubes for glucose indications 0.2 ml with capillary pcs. 3000 0,56
Tubes for designation OB. 0.2 ml pcs 1600 1.28
Tubes for determination of OB. 2-3 ml with label. pcs. 2000 0.52 0.52
OB pipettes with 6000 scale 0,59
System needles 0.9 x 38 mm pcs 65000 0.45
System needles 0.8 x 38 mm pcs 100000 0.45
System needles 0.7 x 38 mm pcs 5000 0.45
System needles short 0.8 x 25 mm pcs 1200 0.45
Butterfly needles 0.8 drain length 80mm pcs 600 1,38
Butterfly needles 0.9 drain length 80mm pcs 600 1,375
Butterfly needle for blood chops sterile packaged one at a time, ready to be used entirely with a drain length of 200 mm pcs 600 1,43
Capillaries for gasometry of non-breakable transparent plastic type PET 125 μl and d 2.05 mm, with heparin sodium 20000 0,473
External capillary plugs made of soft rubber pcs 20000 0,11
Stirator for gas capillaries Ø 1 mm pcs 20000 0.10
Drain openers constituting a tube stopper with a diameter of 12mm pcs 12000 0,39
Connectors compatible with Luer type 18000 0.44
Membrane connectors for the administration of drugs, pcs. 1000 0.22
Adapter with shoulder blade to perform full peripheral blood smear 2000 0.47
Sterile round rod tube with nut made of PP (polypropylene) .10ml H 92 mm, Ø 15,3 mm pcs. 500 0,39
Membrane adapter for Luer systems pcs. 200 0,22
Multi Adapter 36000 0.44
Tubes for marking neutral. 2-3 ml pcs. 200 0.44
Disposable tourniquet 10000 0.77
Transport container for internal transport of samples, measuring 320x230x190mm, base and lid with handle made of light gray plastic (ABS) .The container must hold 100 pieces of tubes with a diameter of 16 mm in tripod and 3 containers for urine.
Part 72Flexible salivine tips designed for single use, Made of transparent, non-toxic PVC. Ideal when performing procedures with irritated mucosal membrane.Dimensions: diameter 6.5 mm.Medical product Class IIa. pack 132
Part 73Mammal filter CA-MI REF M.03.1.003 size 6 mm pcs 9
Part 74Mammal Filter CA-MI REF 03.1.003 SIZE 8 MM pcs 9
Part 75Single-use Endoirrigation Needles Sterile Dental Root Duct Packing 100pcs Size 3*25 Pack 24
Part 76Needles for carpol disposable sterile silicone with sliced bevel size 0.3*16 mpacking 100 pcs pack 36
Part 77Needles for carpools disposable sterile silicone with marking bevel size 0.40* 35 mm Packaging 100 pcs pack 8
Part 78Surgical mammal tips universal molded diameter 11 mm length 200 mm coler light grey pack 10 pcs pack 20
Part 79Disposable cartridge for mammal FLOVAC 1000ml pcs 200
Part of the 8th“Caesarean section kit
Composition and dimensions:
a) T-shaped surgical service for caesarean section of 175/250x300 cm, having a hole measuring 38x32 cm, filled with surgical film, inside which there is a pear-shaped notch measuring 18x16 cm. The servet has a large integrated, enveloping fluid capture bag measuring 100x80 cm equipped with a stiffer, mammal connection and conductor organizers. Sheet made of min. double layer laminate (one of the layers is to be PE film) with min. weight 65 g/m2, resistance to penetration of liquid min 140 cm H2O, resistance to taxidermy in the drought/wet zone 170/105 kPa. — 1 pcs.
b) Servet - wrap of newborn 90x120 cm — 1 pc
c) Adhesive tape, waterproof 9x49 cm, made of double-layer laminate, one of the layers is supposed to be PE film - 1pc
d) Cellulosic absorbent towels 18x25 cm — 4 pcs
e) Mayo Table Cover 79x145 cm - 1 pc
f) Table coverlet (wrap kit) 150x190cm, absorbent layer 75x190 cm. Sheet made of double layer laminate (PE non-woven/foil) weighing min. 70 g/m2 - 1pcs.
Packaging paper-foil bag or foil with label in Polish with at least two stickers to be pasted in medical records as no. The product sterilized according to the standards required by law. Quantity in package 8 pcs.” pcs.100
Part 80Drain fastener size 6-9/5 pack 10 pcs pack 20
Part 81Nylon bristle brushes designed for application of preparations in the form of liquid and gel pack 100 pcs pack 20
Part 82Histopathological clippings container with a cap 15 ml pcs 60
Part 83Dual Layer Operating Dual Layer 45*75 cm pcs 40
Part 84String bags 120*80 for dental squeezes pack 100 pcs pack 40
Part 85Operating Field Suction Kit CH24/400 mm Sterile Pcs 200
Part 86Indoor tips facilitate application of compression masses DI.1100.02 yellow pack 50 pcs pack 2
Part 87Mixing tips for light silicone masses rarely medium flowing yellow pack 50 pcs pack 3
Part 88Adapter for FLOVAC yellow pack 5 pcs pack 20
Part 89Closed system for non-invasive measurement of intra-abdominal pressure by manometric method (factory-combined set for hourly urine collection with measuring line, sterile, in one package which ensures the maintenance of the closed system), 20 ml manometric drains equipped with biological filter, placed between the foley catheter and the set for hourly urine collection, ensuring proper venting. An anti-return valve built into the foley catheter connector prevents urine from receding the urine from the urine collection kit to the measuring line. Integrated drain clamp for pressure alignment and precise reading of intra-abdominal pressure values, needle-free sampling port, measuring line scaled in mm Hg, use time up to 7 days. PCS 30
Part of the 9th“Bag for capturing fluids with a hole
Fluid capture bag measuring 100x80cm, having a hole filled with a surgical film measuring 38x32cm. The bag is equipped with a stiffer, a valve for connecting the drain and organizers of the wires. Quantity in packaging 22 pcs” pcs.100
Part 90KTG belt - flexible, disposable with button holes for optimal head placement. Belt min 6 cm wide and min120 cm. Includes 2 belts of 2 different colors along with buttons. Product registered as medical device SZT 50
Part 91KTG- flexible multiphase belt with button holes for optimal placement of heads. Belt min 6 cm wide and min130 cm Includes 2 belts along with buttons. Product registered as medical device SZT 25
Part 92Gauze enveloped 100% cotton, barren, made of 17-thread gauze. Yarn min. 15 TEX. Class 2a, rule 7. Type of sterilization: steam. 1 m2 pcs. 10 000
½ m2 pcs. 5,000
¼ m2 pcs. 3,000
Dressing gauze 100% cotton, non-alloy, of gauze 17-to thread-yarn min. 15 TEX. Class 2a, rule 7. width 90 cm mb 10,000
Part 93Non-allium gas compresses 17- thread 12- layer packaged 100 pcs. Yarn min. 15 TEX. Class 2a, Rule 7. Eco-friendly paper packaging. 5 x 5 cm gauze cut size min. 15.5x19cm, weight 1 compress piece min. 0.75g. Op. 2 700
7.5 cm x 7.5 cm gauze cut size min. 23x29cm, weight 1 piece of compress min. 1.65g. op. 1 200
10 cm x 10 cm gauze cut size min. 30.5x39cm, weight 1 piece of compress min. 2.62g. Op. 1 000
Non-allium 17- thread 16- layer gas compresses with radiative thread packed 100 pcs min.15 TEX yarn. Class 2a, rule 7. Ecological paper packaging. 7.5 cm x 7.5 cm gauze cut size min. 29x29cm, weight 1 piece compress min. 2.05g. op. 200
10 cm x 10 cm gauze cut size min. 39x39cm, weight 1 piece compress min. 3.65g op. 1 000
Gas compresses, barren of 17-thread gauze, 12-layer packed 5 pcs. Yarn min. 15 TEX. Class 2a, rule 7. Type of sterilization: water vapor. Soft blister packaging with a pictogram of opening direction applied to the paper part, as well as with a sterilization indicator located outside the loading field. 5 x 5 cm gauze cut size min. 15,5x19cm, weight 1 piece of compress min. 0.75g. op. 1 500
7.5 cm x 7.5 cm gauze cut size min. 23x29cm, weight 1 piece of compress min. 1.65g. op. 2 100
10 cm x 10 cm gauze cut size min. 30.5x39cm, weight 1 piece of compress min. 2.62g. op. 4,500
Gas compresses, barren of 17-thread gauze, 12-layer packed 10 pcs. Yarn min. 15 TEX. Class 2a, rule 7. Type of sterilization: water vapor. Soft blister packaging with a pictogram of the opening direction applied to the paper part, as well as with a sterilization indicator located outside the loading field. 5 x 5 cm gauze cut size min. 15,5x19cm, weight 1 compress piece min. 0,75g. op. 2 500
7.5 cm x 7.5 cm gauze cut size min. 23x29cm, weight 1 piece of compress min. 1.65g. op. 5,000
10 cm x 10 cm gauze cut size min. 30.5x39cm, weight 1 piece of compress min. 2.62g. Op. 7,000
Gas compresses, barren, of 17-thread, 16-layer gauze packed 10 pcs with X-ray thread. Packaged in a paper-foil bag with special welding along the shorter side with an obtuse V-shape - the so-called chevron, which further facilitates dust-free opening of the package, in the bag there are cut cuts for the thumb to capture the film with your thumb for easier opening. packaging.Paper and foil bag with large readable double-perforated label with 2 TAGs on the package (information on tags: expiration date, index, LOT number, barcode). After the 2 tags are peeled off, the main label remains on the part of the package. Dressing material yarn min. 15 TEX, type of sterilization: steam. Required validation report of the sterilization process. Dressing material class 2a rule 7. 7.5 cm x 7.5 cm gauze cut size min. 29x29cm, weight 1 piece compress min. 2.15g. op. 1 000
10 cm x 10 cm gauze cut size min. 39x39cm, weight 1 piece of compress min. 3,75g. Op. 3 300
Part 94Non-woven compress, weight 40 g/m2, 4 - layers, packed 100 pcs. Class 2a, Rule 7. Ecological Paper Packaging. 5 cm x 5 cm Op. 5,000
7.5 cm x 7.5 cm Op. 2,000
10 cm x 10 cm, op. 1,600
Cotton dressing cotton 500g, medical device, op. 20
Cellulosic washboard in lobes, bleached 60cm x 40 cm. Requirement - medical device. 5 kg, op. 400
1 kg Op. 40
Cellulosic wadding in lobes, bleached 20 cm x 30 cm. Requirement - medical device. 0.5 kg, op. 60
Cellulosic washboard in rollers, bleached. Requirement - medical device. 150 g. op. 50
Pulp cotton wool compress in a roll with regular perforation to facilitate detaching of individual parts, hypoallergenic, 10- layer, white non-alloy. Roll of 500 pcs. 4 cm x 5 cm, Op. 100
Part 95Dispenser for pulp compresses with perforation made of plastic, transparent, can be washed, disinfected, non-allium. For 4cmx 5cm x 1pcs compresses, Op. 5
Part 96Barren Treatment Kit consisting of 5 packs of 10 pcs of 17 thread-16 layer compresses with X-ray threads with cotton thread and transparent round plastic container with a min. capacity of 250 ml. Packaged in a paper-foil bag with special welding along the shorter side with an obtuse V-shape - the so-called chevron, which further facilitates dust-free opening of the package, in the bag there are cut cuts for the thumb to capture the film with your thumb for easier opening. packaging.Paper and foil bag with large readable double-perforated label with 2 TAGs on the package (information on tags: expiration date, index, LOT number, barcode). After the 2 tags are peeled off, the main label remains on the part of the package. Dressing material yarn min. 15 TEX, type of sterilization: steam. Required validation report of the sterilization process. Dressing material class 2a rule 7. 7.5 cm x 7.5 cm gauze cut size min. 29x29cm, weight 1 piece compress min. 2.15g. op. 600
10 cm x 10 cm gauze cut size min. 39x39cm, weight 1 piece of compress min. 3,75g. op. 600
Part 97Non-alum gynecological primers intended for the absorption of secretions during the period and after gynecological procedures. Made of absorbent cellulose cartridge wrapped in hygiene tissue paper and a delicate non-woven outer layer. The insulation part is a sheet of film located at the bottom of the primer between the cartridge and tissue paper, making the primer waterproof. The film in blue makes it easy to distinguish the underside. The primer is suitable for steam sterilization. Size 34x9, providing protection even in the prone position. Packed 10 pieces each. Medical device registered in class I rule 4. Inflammability min. 23 g/g. 34 cm x 9 cm, op. 1 000
Gynecological primers are intended for the absorption of secretions during the period of postpartum and after gynecological procedures. Made of absorbent cellulose cartridge wrapped in hygiene tissue paper and a delicate non-woven outer layer. The insulation part is a sheet of film located at the bottom of the primer between the cartridge and tissue paper, making the primer waterproof. The film in blue makes it easy to distinguish the underside. The primer is suitable for steam sterilization. Size 34x9, providing protection even in the prone position. Packed 10 pieces each. Medical device registered in class I rule 4. Increment min. 23 g/g. 27 cm x 7.5 cm, op. 600
Part 98Non-woven compress, non-alum with X-ray thread, weight 40 g/m2, 4 - layers, packed 100 pcs. Class 2a, rule 7. Designed for sterilization of min water vapor. Eco-friendly paper packaging. 10cm x 10cm Op. 100
Gas compresses, barren of 17-thread gauze, 6-layer packaged 5 pcs. Yarn min. 15 TEX. Class 2a, rule 7. Type of sterilization: water vapor. Price given with 1 pc 90 cm x 20 cm pcs. 100
Part 99Sterile polyurethane dressing for fixing central catheters with two small cutouts. Size 10 x 12 cm with wide applicators (min. 2.5 cm), laminated tag and wide laminated non-woven strap with a notch. Ponacinane transversely edged reinforced from the underside with a non-woven on each side. Quick application in 2 steps (security paper and frame). Acrylic glue applied to the mesh (film) in a way that guarantees high vapor permeability. Resistant to alcohol-containing disinfectants. Packing of foil type. 10 cm x 12 cm pcs 50
Bactericidal adhesive polyurethane dressing for fixing central catheters with excision and with hydrogel containing 2% chlorhexidine gluconate. Instant bactericidal effect after application. Size 8.5 x 11.5 cm with wide applicators (min. 2.5 cm), price tag and 2 non-woven strips. The edging reinforced from the underside with a non-woven on each side. Quick application in 2 steps (security paper and frame). Acrylic adhesive applied in a way that guarantees high vapor permeability. Resistant to alcohol-containing disinfectants. Paper film wrapping 8.5 cm x 11.5 cm pcs 60
Sterile polyurethane dressing for fixing peripheral cannulas with a notch. Size 6 x 7 cm with frame and tag. Resistant to alcohol-containing disinfectants. Acrylic glue applied evenly. Packing of foil type. 6 cm x 7 cm pcs 1 500
Sterile polyurethane dressing for fixing peripheral cannulas in children with a notch. Size 5 x 5.7 cm with wide applicator (min. 3 cm). Colorful app for kids. Strengthening with non-woven. Resistant to alcohol-containing disinfectants. Acrylic glue applied evenly. Packing of film type 5 cm x 5.7 cm pcs 60
Barren blade for securing perimeter inserts for mounting cannul, self-adhesive made of hydrophobic non-woven, covered with hypoallergenic acrylic adhesive, has a protective layer of silicone paper to facilitate precise painless and effective application, measuring 7.6 x 5,1 cm 7.6cm x 5.1cm pcs 35,000
Surgical, hypoallergenic, of microporous non-woven polyester without viscose and cellulose content, with macro-perforation over the entire surface, allowing scissor-free split along and across, with acrylic adhesive evenly applied over the entire surface, without the content of oxide zinc, rubber and latex, waterproof, high adhesion at the time of application and long time. 2.50 cm x 9.14 m pcs 2 500
5.0cm x 9.14pcs 50
Surgical, hypoallergenic, microporous non-woven, with waterproof evenly applied to the entire surface with acrylic glue, without latex, rubber and zinc oxide, extremely delicate for the skin. 7.50 cm x 9.14 m pcs 20
5.00 cm x 9.14 m pcs 20
2.50cm x 9.14m pcs 1,500
Surgical, hypoallergenic, elastic foam (PVC), with waterproof acrylic adhesive, evenly applied over the entire surface, without latex, rubber and zinc oxide, stretchable along and across, allowing compression dressings and on moving parts of the body. 00 cm x 5.00 m pcs 20
7.50 cm x 5.00 m roll 10