Open Telematic Procedure for the supply of Electromedical Equipment to be allocated to Hospitals, Health Districts and Departments of the Salerno ASL. Project "Por Campania Fesr 2014-2020 - Axis 1 - Specific objective 1.6 - Action 1.6.1. Intervention "Strengthening of the Diagnostic-Therapeutic Path of the Patient in the Post-Covid era" – Cup C59I23000250002, and any other funding.
Cardiological stress analysisSystem for the evaluation of the cardiovascular efficiency of a patient subjected to stress by means of
detection of the electrocardiogram consisting of:
• N. 1 system for the detection and management of ECG parameters
• N. 1 moving belt platform for the execution of the effort
• N. 1 cycle ergometer
Biometric stationBiometric parameter analysis station consisting of one or maximum two devices capable of
Detect the following parameters:
-WEIGHT
-HEIGHT
- BODY COMPOSITION
- BLOOD PRESSURE - NIBP
- HEART RATE - HR
- SATURATION - SPO2
-TEMPERATURE
Clinical Chemistry StationPOCT workstation, composed of one or more automatic systems able to provide the following analytical profiles
(measured or calculated):
- GLYCEMIC PROFILE
- HEPATIC PROFILE
- RENAL PROFILE
- LIPID PROFILE
- HEMATOLOGICAL PROFILE
Visual functional assessmentVisual functional assessment apparatus capable of verifying:
- Refractometric characteristics;
-Keratometry features
- Pachymetry characteristics
- Tonometry characteristics
- Features dry eye analysis
- Color display of no less than 9"
- Fully automatic acquisition with auto-alignment
- Integrated thermal printer
- DICOM compatible
- Mains power supply
- Complete supply of: Electrically adjustable height adjustable ophthalmology table with suitable floor and dimensions
the housing of the instrument ; Paper starter kit dedicated to the printer (at least 10 rolls)
-CE marking in accordance with Directive 93/42/EEC and subsequent amendments. or the new MDR
2017/745 and subsequent amendments. and all relevant technical reference product standards
Peripheral Vision AnalyzerConventional computer peripheral vision analyzer (dome and stimulus projection) according to Goldmann capable of performing static and kinetic perimetric examinations
EcooftalmografoNew and latest generation ultrasound equipment that performs ocular ultrasound
FluorangiografoHigh-resolution digital fundus image acquisition system
Image capture: color, black-white, red-free (aneritra)
The system must offer at least the following imaging modes:
- Fluorescein angiography (FA)
- Background autofluorescence (FAF)
- Indocyanine angiography (ICGA)
Recovery of small diameter pupils
Movement at least up/down
At least three scan/magnification angles/fields of view between at least 20° and 50°
Wide diopter compensation range
Mains power
Capture unit and dedicated workstation:
- Latest generation PCs
- Monitor of at least 19"
- Color laser printer
- Image storage system not less than 1Tb
Complete with ELECTRIC TABLE for ophthalmology with the following characteristics:
- electric lifting
- load capacity suitable for the fluorescein angiography instrument
- adjustable height in an indicative range between 650 and 840 mm
- complete with isolation transformer
CE marking in accordance with Directive 93/42/EEC and subsequent amendments. or the new MDR 2017/745 and subsequent amendments. and all relevant technical reference product standards
Laser a femtosecondiFemtosecond laser for ophthalmic surgery for SURGICAL PROCEDURES, such as:
- Keratoplasty for corneal transplantation
- Cataract surgery
The system must be ergonomic, compact and easily sanitized with the most common detergents / disinfectants used in hospitals, preferably transportable
Electric hospital bedsElectric movement bed for adult patients, equipped with 4 sections and 3 joints
Portable for X-rayDirect and motorized digital mobile radiological system that allows X-ray examinations at the patient's bed and suitable for use in radiology, intensive care, operating room, emergency room, departments,
in the lane.
Mobile patient passport systemMobile patient tray system dedicated to the safe and atraumatic intra-hospital movement and transfer of patients, which can also be used by a single operator and suitable for critically ill, operated and operated patients
Cardiopulmonary stress analysisSystem for the evaluation of the cardiovascular and respiratory efficiency of a patient subjected to stress
by detecting electrocardiogram, spirometry, gas exchanges. composed of:
• N. 1 system for the detection and management of ECG and spirometry parameters
• N. 1 moving belt platform for the execution of the effort
Corneal tographComputerized corneal tograph dedicated to the superficial mapping of the cornea (anterior and posterior) and to the analysis of the anterior segment of the eye and of low weight and bulk (benchtop)
AI Video ProcessorHardware platform (video processor) including artificial intelligence software on colorectal lesions
Portable ecotomographMultidisciplinary portable ecotomograph
ElectrocardiographMicroprocessor-managed, 12-channel electrocardiograph for use on both adults and pediatricians
High band slit lampConvergent Galilean binocular microscope
- Adjustable LED source
- At least four magnifications between 6.5x and 40x
- Ocular diopters at least from -7D to +7D
- Eyepieces at least 12.5x
- Interpupillary distance between 55 and 75mm
- Adjustable slot width at least between 0 and 12mm
- Adjustable slot length at least between 1 and 12mm
- At least four iris values between 0.2 and 8mm
- Rotation of the slot not less than 180° (±90°)
- Maximum tilting of the crack not less than 13°
- Joystick for movement in width, height and rotation of the slot
- Floor and chin guard
- Table of adequate size to house both the lamp and the entire image management system
- Mains power supply
- Image acquisition system (included in delivery) with the following features:
Built-in digital camera with no lower resolution than 5MPixel
High-resolution camera imaging
Number of images per second not less than 15 fps
Image acquisition via slit lamp joystick
Dedicated hardware system for image management consisting of a PC complete with all the peripherals necessary for operation and a color photo printer
Dedicated image management software
- CE marking in accordance with Directive 93/42/EEC and subsequent amendments. or the new MDR 2017/745 and subsequent amendments. and all relevant technical reference product standards
Outpatient slit lampConvergent Galilean binocular microscope
Adjustable LED source
At least four magnifications between 6.5x and 40x
Ocular diopters at least -5D to +5D
Eyepieces at least 12.5x
Interpupillary distance between 55 and 75mm
Adjustable slot width at least between 0 and 12mm
Adjustable slot length at least between 1 and 12mm
At least four iris values between 0.2 and 8mm
Rotation of the slot not less than 180° (±90°)
Maximum slot tilting not less than 13°
Joystick for movement in width, height and rotation of the slot
Floor and chin guard
Complete with applanation tonometer compatible with the lamp
Electrically adjustable height table
Mains power
CE marking in accordance with Directive 93/42/EEC and subsequent amendments. or the new MDR 2017/745 and subsequent amendments. and all relevant technical reference product standards
Electrified examination tableCot dedicated to the execution of visits, composed of at least two sections (back and body), back section adjustable approximately between -10 ° and + 65 ° electrically, electrically adjustable height in an indicative range between 50 and 90 cm, push-button panel for handling management, cushions made of foam or equivalent material, ergonomic, solid, resistant and fireproof with
high density padding, made of resistant, antibacterial materials and easily sanitized with the most common detergents used in hospitals, maximum capacity of not less than 180 kg, mains feeding, complete with roll holder, CE marking in accordance with Directive 93/42 / EEC and subsequent amendments. or the new MDR 2017/745 and subsequent amendments. and all relevant technical reference product standards
Pressure holter systemSystem composed of:
• N. 2 holter blood pressure recorders (please quote each individual separately
recorder in order to ensure any integration to the minimum number provided)
• N. 1 holter reader
Portable SprirometerSuitable for adult and pediatric patients, rapid, non-invasive, which measures the inspiratory and expiratory phase and guarantees at least the measurement of static and dynamic lung volumes that allows the comparison of Pre and Post drug with theoretical values, with memory of at least 1000 tests, display for displaying all measured parameters and flow-volume curves, complete with software to download data to the PC and allowing the visualization of the results and curves of the executable tests, easy-to-use multi-windows graphics, real-time display curves, direct printing on an integrated printer of all exam results, compact, small and easy to carry, complete with carrying bag
Complete with at least:
• n.50 disposable mouthpieces
• n.50 rolls/reams of dedicated thermal paper for the integrated printer
CE marking in accordance with Directive 93/42/EEC and subsequent amendments. or the new MDR 2017/745 and subsequent amendments. and all relevant technical reference product standards