Hallerwiese Clinic, new extension of the Cnopf Children's Clinic with central emergency room, intensive care,
Pediatric nursing and surgeries.
A total of approx. 11,000 m² GFA, level -03 to level +04
- approx. 4,997 m² partition wall non-load-bearing, without fire protection requirement, wall thickness 100-200 mm, UK sheet steel profile verz, single stud structure, insulating layer made of mineral wool, planking on both sides made of gypsum building boards, filler Q2
- approx. 1,774 m² partition wall non-load-bearing, fire protection requirement F30-F90, wall thickness 150-170 mm, UK sheet steel profile verz, single stud structure, insulating layer made of mineral wool, planking on both sides made of gypsum construction and fire protection boards, filler Q2
- approx. 99 m² partition wall non-load-bearing, fire wall, radiation protection requirement, wall thickness 151-152 mm, UK sheet steel profile verz, single stud structure, insulating layer made of mineral wool, planking on both sides made of gypsum construction and fire protection boards, filler Q2
- approx. 190 m² partition wall non-load-bearing, without fire protection requirement, with radiation protection requirement, wall thickness 150.5-201 mm, UK sheet steel profile verz, single stud structure, insulating layer made of mineral wool, planking on both sides made of gypsum building boards, filler Q2
- approx. 725 m² partition wall non-load-bearing, without fire protection requirement, wall thickness 225-450 mm, UK sheet steel profile verz, double stud work, insulating layer made of mineral wool, planking on both sides made of gypsum building boards, filler Q2
- approx. 57 m² partition wall non-load-bearing, fire protection requirement F30-F90, wall thickness 275-300 mm, UK sheet steel profile verz, double studs, insulating layer made of mineral wool, planking on both sides made of gypsum construction and fire protection boards, filler Q2
- approx. 152 m² shaft wall, without fire protection requirement, wall thickness 125 mm, UK sheet steel profile verz, single stud structure, insulating layer made of mineral wool, planking on both sides made of gypsum building boards, filler Q2
- approx. 491 m² facing shell, without fire protection requirement, wall thickness 125 mm, UK sheet steel profile verz, single stud structure, insulating layer made of mineral wool, planking on both sides made of gypsum building boards, filler Q2
- approx. 291 pcs. door opening incl. substructure in partition wall D: 12.5-15.1cm
- approx. 1,350 wall openings TGA round / square
- approx. 238 openings / installation of fire dampers
The integration of painter 1 results in the following positions:
approx. 4353m² Cleaning the substrate Walls
ca.2801m² Initial wall concrete emulsion paint
ca.1298m² Initial wall sand-lime brick emulsion paint
approx. 1493m² Cleaning the substrate Ceilings
approx. 1493m² Initial ceiling concrete emulsion paint