Cardiac surgery devices | Tenderlake

Cardiac surgery devices

Contract Value:
-
Notice Type:
Contract Notice
Published Date:
08 September 2023
Closing Date:
05 October 2023
Location(s):
PL POLSKA (PL Poland/POLSKA)
Description:
Successive deliveries of ablation equipment using a 3-D electroanatomical system, stimulators with resynchronization function, balloon for intravascular lithotripsy

Supply of ablation equipment using a 3D electroanatomical system, stimulators with resynchronization function, balloon for endovascular lithitripsy

Assortment for ablation using a 3D electroanatomical system with lease of an RF generator

item 1 - Electrode for RF ablation using a 3D electroanatomical system - diameter 7-8F, length 115 cm, number of poles - 4, seroki range of curvatures (D, F, J) to be chosen by the Ordering Party, temperature monitoring sensor, ablation pole: 4 mm and 8 mm (at the Customer's choice), cooperation with the RF generator from position 14, distance between rings: 1-6-2 mm, 2-5-2 mm or 1-7-4 mm, deposit: 2 pieces - 6 pieces;

item 2 - Electrode for RF ablation using a 3D electroanatomical system with a liquid-cooled tip - diameter 8F, length: 115 cm, number of poles: 4, one or bidirectional, adjustable tip bending - to be chosen by the Ordering Party, wide range of curvatures (D, F, J) or (DD, DF, FF, FJ, JJ) to be chosen by the Ordering Party, cooling the electrode tip with saline, temperature monitoring sensor, ablation pole: 3.5 mm, cooperation with RF generator from position 14, distance between rings: 1-6-2 mm, 2-5-2 mm or 1-7-4 mm, deposit: 2 pcs, - 50 pieces;

item 3 - Fasteners with catheters from items 1 and 2, deposit: 1 pc., - 14 pieces

item 4 - RF ablation electrode using a 3-D electroanatomical system with a pressure sensor, cooled by liquid - diameter 7-8 F, length: 115 cm, number of poles: -4 +2 or bidirectional, adjustable tip bending - to the Ordering Party's choice, wide range of curvatures (D, F, J) or (DD, DF, FF, FJ, JJ) - to be chosen by the Ordering Party, pressure sensor, temperature monitoring sensor, cooperation with ablation generator: 3.5 mm, cooperation with generator from position 14, cooperation with pump from position 15, distance between rings: 1-6-2 mm, 2-5-2 mm or 1-7-4 mm, deposit: 5 pieces, - 80 pieces;

item 5 - Fittings compatible with catheters from item 4, deposit: 2 pieces - 20 pieces;

item 6 - Set of reference electrodes - compatible with the 3D electroanatomical system, deposit: 10 pcs., 150 pieces;

item 7 - Wire connecting the RF current generator with the 3D electroanatomical system - deposit: 2 pcs., - 4 pcs.;

item 8 - Pump drains - komaptybilme with infusion pump from item 15, deposit: 10 pcs. - 130 pcs.;

item 9 - Lease of the electroanatomical 3D system - installed the latest available version of the software, magnetic catheter navigation technology, creating an ultra-high density map using automatic position annotation: 1,2,3,10,12 and visualization of the T-shirt from position 16, installed module enabling automatic marking of ablation points on the basis.

A detailed description of the subject of the order shall be provided with SWZ with attachments

Balloon for endovascular lithotripsy

item 1 - Lithotripsy balloon 12 mm long, in sizes: 2.5 - 4 mm, deposit: 2 pcs - 20 pcs.;

item 2 - Lease of a sonic wave generator - 24 months.

Cardiac pacemaker with resychronization function (CRT-P) with equipment, adapted to perform magnetic resonance imaging (pro MR)

pos. 1 - Cardiac pacemakers with resynchronization function (CRT-P)

Suitable for magnetic resonance imaging (proMRI) 1. Weight < 35 g; 2. Warranty for the entire expected life of the battery 2. A guaranteed battery life of at least 5 years under standard conditions;

3. Tryby stymulacji min. - DDD, DDDR, AAI, AAIR, VVI, VVIR ;

4. Ability to change the mode of operation in case of detection of atrial arrhythmia;

5. Algorithm supporting resynchronization therapy in case of loss of A-V synchronization;

6. Programmable function to increase the percentage of resynchronization stimulation in the presence of AF/AT;

7. Response function (stimulation pulse) when own ventricular excitations are detected

8. Automatic measurement of stimulation threshold and adjustment of stimulation amplitude on each channel (A, RV, LV);

9 . Possibility to program parameters on each channel independently; 10. Automatic electrode impedance monitoring and the ability to change the polarity of stimulation;

11. EGM recording length > 10min;

12. Automatic optimization of AV and VV latency;

13. IS1/IS4 left chamber connector (selectable)

The manufacturer provides 8 sets of cables to the analyzer free of charge

REMARK!!! The Contractor undertakes to provide the programmer and paper to the programmer printer free of charge in an amount appropriate to the number of ordered devices. Note: The ordering party requires the provision of passports and patient information/instructions.

Deposit: 3 pcs. - 20 pcs.;

pos. 2 - Left chamber electrode - "over the wire" bipolar/four-polar electrode with IS-1/IS4 connector (optional), electrode with silicone or polyurethane casing, electrodes with different end shapes (min. two to choose from), length min. 70 cm. Deposit: 3 pcs., - 20 pcs.;

item 3 - Stimulating Electrodes - active/passive to be chosen by the Ordering Party, electrode length from 45 cm to 65 cm (at the choice of the Ordering Party). Deposit: 3 pcs. - 20 pcs.;

item 4 - Set for coronary sinus cannulation - various curvatures of "shirts" for the coronary sinus - 30 pcs.;

pos. 5 - Balloon catheter for coronary sinus venography - 30 pcs.;

item 6 - T-shirt for the coronary sinus - 20 pcs.;

item 8 - Knife for cutting T-shirts - 20 pcs.;

item 8 - Guide - 20 pcs.

Download full details as .pdf
The Buyer:
Wielospecjalistyczny Szpital Miejski im. dr. Emila Warmińskiego SPZOZ
CPV Code(s):
33140000 - Medical consumables
33141000 - Disposable non-chemical medical consumables and haematological consumables
33182300 - Cardiac surgery devices