Carpentry work - wall protection BA1+BA2
General description of wall protection:
Non-combustible wall protection (A2-S1,d0):
HPL compact panel, panel thickness approx. 9 mm, height min. 1.40 m
Wandschutz normal entflammbar (Efl):
melamine resin-coated chipboard, panel thickness approx. 8 mm, height min. 1.40 m
Assembly:
visibly screwed, stainless steel screws in the colour of the wall protection
Wall protection TH2 (BA1), height at least 1.40 m:
- Production and assembly planning, construction site equipment
- 90.00 m2 wall protection non-combustible A2-S1,d0
Wall protection on landings and corresponding stair course on the stairwell walls
with lower notch
-Other:
12.00 m end / corner protection rail stainless steel
E-socket cut-outs, spacer plates for railing brackets incl. cut-outs
Wall protection north wing (BA2):
- Production and assembly planning, construction site equipment
- EG:
140.0 m2 wall protection non-combustible A2-S1,d0
40,0 m2 Wandschutz normal entflammbar Efl
86.0 m End / corner protection rail stainless steel
- 1.OG:
170,0 m2 Wandschutz normal entflammbar Efl
12.0 m2 wall protection normally flammable Efl; Height approx. 1.10 m
40.0 m end / corner protection rail stainless steel
- 2.OG:
90,0 m2 Wandschutz normal entflammbar Efl
25,0 m2 Wandschutz normal entflammbar Efl
14.0 m end / corner protection rail stainless steel
-MEDICAL HISTORY:
95.0 m2 wall protection non-combustible A2-S1,d0
- 18.0 m end / corner protection rail stainless steel
- TH1:
130,00 m2 wall protection non-combustible A2-S1,d0
Wall protection on landings and corresponding stair course on the stairwell walls
with lower notch
30.0 m end / corner protection rail stainless steel
- TH3:
138,00 m2 Wall protection non-combustible A2-S1,d0
Wall protection on landings and corresponding stair course on the stairwell walls
with lower notch
42.0 m end / corner protection rail stainless steel
-Other: