structural work
Drainage, earthwork, reinforced concrete, masonry work.
The buildings are built in solid construction (reinforced concrete and masonry) with a clinker facade.
The on-site excavation pit will have a size of approximately 90 mx 40 m.
Underground car park:
One-story, complete under both parts of the building (residential building and nursing home) and parts of the outdoor area.
OK original area or planned area.
Underground car park:
Axis AS / 1-20 plus entry and exit. OKFF TG = -3.50 = +127.50 g. NN
Entry and exit on the main street:
This is located between axis 9 and the border to the Christkönigkirche, axis AG.
The level of entry and exit at the border to the main street is
OK = +0.30 = +131.30 a. NN
Exit on the street "Hinter der Heck":
This is located between axis 20 and the border to the kindergarten.
The level of the exit at the border to the street "Hinter der Heck" is OK = +1.10 = +132.10 ü. NN
Residential house for seniors:
The residential building has a three-story part (ground floor-2nd floor) with a flat roof and a four-story part
Part (EG-DG) with a gable roof. OK original site or planned site see attached planning.
Saddle roof structure:
Axis AD / 1-9
OKFF EG = + -0.00 = +131.00 over. NN
OK eaves = approx. +10.20 = approx. +141.20 a.s.l.
OK dormer = approx. +12.25 = approx. +132.25 above sea level
OK First = approx. +17.65 = approx. +148.65 above sea level
Flat roof structure:
Axis DH / 5-9
OKFF EG = + -0.00 = +131.00 over. NN
OK parapet, raw = +9.70 = +140.70 a.s.l.
Building for house communities (nursing home):
The house has three floors and a flat roof.
Building (nursing home):
IS / 10-20 axis
OKFF EG = +0.60 = +131.60 ü. NN
OK raw roofing = +9.94 = +140.94 a.s.l.
OK parapet raw = +10.29 = +141.29 a.s.l.
OK parapet elevator = approx. +11.20 = approx. +142.20 a.s.l.
Main masses:
- approx. 90 m ground lines;
- approx. 835 m
- approx. 540 m
- approx. 2 700 m
- approx. 415 m
- approx. 2 365 m
- approx. 2,000 m
- approx. 5 040 m
- approx. 9 100 m
- approx. 370 m
- Approx. 4 pieces of precast reinforced concrete systems;
- approx. 53 m
- approx. 2 850 m
- approx. 85 m reinforcement with insulating body;
- approx. 765 t of structural steel.