Renovation and conversion of the existing workshop, gross floor area 1,560 m², new construction of a workshop building, gross floor area 1,061 m²
GENERAL: 1 psch sampling of built-in parts, fittings, operating sets; 3 pcs hand samples powder coating;
OLD BUILDING: Work planning doors old building; Acceptances + documentation; Construction period protection: 17 pcs Bauzeitl. Protection for door frames up to HxW 2.60x2.10m, solid board min. 3 mm; sheet steel doors with sheet steel frames; 8 pcs. interior door 1-flg, 101x213,5, with enclosure.zarg.; 1 pcs interior door 1-flg, 101x213,5, with enclosure.zarg., 37 dB; 1 pcs interior door 2-flg, 201x250, with enclosure.zarg., DIN EN 179, 37 dB; 1 pcs interior door 1-flg, 101x213,5, with enclosure.zarg., T30, moisture-proof door; 1 pcs interior door 1-flg, 101x213,5, with enclosure.zarg., T30, OTS; 1 pcs interior door 2-flg, 201x250, with block frame, T30, hold-open; 1 pcs interior door 1-flg, 115x213,5, with enclosure.zarg., T30, DIN EN 179, OTS, 37 dB, humidity; 1 pcs interior door 2-flg, 148x241,5, with enclosure.zarg., T30, DIN EN 179, hold-open system, 37 dB; 1 pcs interior door 1-flg, 88,5x213,5, with enclosure.zarg., T30, OTS, RC2; 1 pcs interior door 1-flg, 101x213,5, with enclosure.zarg., T30, damp room, 37 dB; Other equipment: 1 piece of hold-open system for 2-flg existing T30 interior door; 1 pcs lowerable floor seal for 2-flg existing T30 interior door; 1 pcs ceiling smoke detector for hold-open systems; 10.2 m cable routing for ceiling smoke detectors; NEW BUILDING: 1 pcs Work planning doors new construction; Acceptances + documentation; Construction time protection: 10 pcs Bauzeitl. Protection of inner door frames up to HxW 2,60x2,10m, made of solid cardboard min. 3 mm; 4 pcs. Protection for door frames H up to 2.20m, wood-based panels; 1 pcs Bauzeitl. Door lock exterior façade HxW up to 3.10x2.5m m, wood-based material; 1 pcs Bauzeitl. Door lock with construction door, exterior façade HxW 3,10x2,50m, wood-based material; Sheet steel doors with sheet steel frames
2 pcs interior doors 2-flg., 201x250 with enclosure.zarg., up to 42 dB, DIN EN 179; 3 pcs interior door 1-flg, 101x213,5 with enclosure.zarg., T30, 37 dB; 2 pcs interior door 2-flg, 201x250 with enclosure.zarg., T30, up to 42 dB, locking bar, DIN EN 179; 2 pcs interior door 2-flg, 201x250 with enclosure.zarg., T30, up to 42 dB, locking bar, DIN EN 179,; Damp room: 2 pcs interior door 2-flg, 168x250, with enclosure.zarg.,, T30, DIN EN 179, ; Lock, up to 42 dB; 2 pcs exterior door 2-flg. 238x300, with block frame, DIN EN 179, RC 2 based on; 1 pcs exterior door 1-flg. 135x230, with block frame, DIN EN 179, RC 2; Spiral door: 1 screw door with fields of vision in exterior façade, WxH 450x300 cm; Other equipment: 1 unit daily release in external doors; 1 pcs door opening limiter for 1-flg. External door; 2 pcs door opening limiter for 2-flg. External door; 4 pcs ceiling smoke detectors for hold-open systems; 10.4 m cable routing for ceiling smoke detectors; A maintenance offer must be submitted for the smoke and fire protection interior doors and the hold-open systems.