Artificial joints | Tenderlake

Artificial joints

Contract Value:
PLN 3M - 3M
Notice Type:
Contract Notice
Published Date:
16 November 2022
Closing Date:
12 December 2022
Location(s):
PL213 Miasto Kraków (PL Poland/POLSKA)
Description:
Supply of endoprostheses and other implants.

The subject of the contract is "Delivery of endoprostheses and other implants". A detailed description of the subject of the contract is contained in the model contract which is Annex 3 to the Specification of the terms of the contract (referred to in the announcement as SWZ) and a description of the subject of the contract which is Annex 8 to the SWZ. The provisions of the SWZ should be read along with possible changes in the content of the SWZ, which are, for example, the result of answers to the Contractors' inquiries. Address of the website where changes and explanations of the content of the Tender Specifications and other procurement documents directly related to the procurement procedure will be made available: https://www.kcr.pl/zamowienia-publiczne-i-ogloszenia/zamowienia-publiczne-2021-2 - "website. of the proceedings being conducted'. The contract is awarded in accordance with the Act of 11 September 2019 – Public Procurement Law (Journal of Laws of 2022, item 1710, as amended), hereinafter referred to as the "PPL" in the form of an unlimited tender, using the so-called "reverse procedure" described in Article 139 of the PPL.

Part (package) 1. Knee replacements

Part (package) 1. Knee joint endoprosthesis, including:

Task 1. Total endoprosthesis of the knee joint - 100 pieces;

Task 2. Knee revision endoprosthesis - 15 pieces;

Task 3. Endoprosthesis of the knee joint - 5 pieces;

Task 4. Endoprosthesis of the knee joint hypoallergenic - 1 piece.

A detailed description of the subject of the contract is contained in the model contract being Annex 3 to the SWZ and a description of the subject of the contract being Annex 8 to the SWZ. The provisions of the SWZ should be read along with possible changes in the content of the SWZ, which are, for example, the result of answers to the Contractors' inquiries.

Part (package) 10: Implants for the reconstruction of the shoulder-clavicle joint

Part (package) 10: Imlants for the reconstruction of the shoulder-clavicle joint, including:

Task 1. The system consists of: titanium plate, surgical tape, nitinol loop - 5 pieces (kpl);

Task 2. Nodal technique of reconstruction of the shoulder-clavicle joint consisting of a button with a superior adjustable loop - 10 pieces;

Task 3. Cannon drill bit - 1 piece.

A detailed description of the subject of the contract is contained in the model contract being Annex 3 to the SWZ and a description of the subject of the contract being Annex 8 to the SWZ. The provisions of the specification should be read along with possible changes in the content of the SWZ, which are, for example, the result of answers to the Contractors' inquiries.

Part (Package) 11: Imlants for Shoulder Arthroscopy

Part (package) 11: Imlants for shoulder arthroscopy, including:

Task 1. Non-absorbable titanium implant - 60 pieces;

Task 2. Non-absorbable titanium implant - 10 pieces;

Task 3. Soft anchor for stabilizing the hem - 30 pieces;

Task 4. Disposable set for implantation of soft anchors designed to stabilize the hem - 2 pieces;

Task 5. Nodal implant made of tube-shaped thread - 10 pieces;

Task 6. Soft anchor to stabilize the hem - 15 pieces;

Task 7. Flexible drill - 2 pieces;

Task 8. Straight drill - 2 pieces;

Task 9. Soft anchor for stabilizing the hem - 10 pieces;

Task 10. Implant in PEEK version for stabilization of shoulder joint instability - 10 pieces.

A detailed description of the subject of the contract is contained in the model contract being Annex 3 to the SWZ and a description of the subject of the contract being Annex 8 to the SWZ. The provisions of the specification should be read along with possible changes in the content of the SWZ, which are, for example, the result of answers to the Contractors' inquiries.

Part (package) 12: Meniscus sewing imlants

Part (package) 12: Meniscus sewing implants - 80 pieces.

A detailed description of the subject of the contract is contained in the model contract constituting Annex 3 to the Terms of Reference and a description of the subject of the contract being Annex 8 to the SWZ. The provisions of the SWZ should be read along with possible changes in the content of the SWZ, which are, for example, the result of answers to the Contractors' inquiries.

Part (package) 13: Slip anchors

Part (package) 13: Slide anchors, including:

task 1 Nodeless implant in the biocomposite version and PEEK for stabilization of tissue in the bone, cannulated implant, hammered - 10 pieces;

task 2 Nodeless implant in the biocomposite version for stabilization of tissue in the bone, canned implant, hammered - 10 pieces;

task 3 Nodeless implant in the biocomposite version and PEEK for stabilization of tissue in the bone, cannulated implant, hammered - 10 pieces;

task 4 Nodeless implant in the Biocomposite version and PEEK for stabilization of tissue in the bone, cannulated implant, screwed in - 30 pieces;

task 5 Node implant in the biocomposite version and PEEK for stabilization of tissue in the bone, cannulated implant, screwed in - 5 pieces.

A detailed description of the subject of the contract is contained in the model contract constituting Annex 3 to the Terms of Reference and a description of the subject of the contract being Annex 8 to the SWZ. The provisions of the SWZ should be read along with possible changes in the content of the SWZ, which are, for example, the result of answers to the Contractors' inquiries.

Part (package) 14: Imlants for the reconstruction of ligament growth and instability of the ankle-shin joint

Part (package) 14: Imlants for the reconstruction of ligament growth and instability of the ankle-shin joint, including:

Asked 1. Implant for the reconstruction of tibia-fibular ligament - two titanium plates - 10 pieces;

Task 2. Implant for the reconstruction of tibia-fibular ligament - two titanium plates - 1 piece;

Task 3. Set for augmentation of protective tape for reconstruction of the anterior sagittal ligament - 5 pieces;

Task 4. Titanium anchor - 30 pieces.

A detailed description of the subject of the contract is contained in the model contract constituting Annex 3 to the Terms of Reference and a description of the subject of the contract being Annex 8 to the SWZ. The provisions of the SWZ should be read along with possible changes in the content of the SWZ, which are, for example, the result of answers to the Contractors' inquiries.

Part (Package) 15: Bioabsorbable Interference Screw

Part (package) 15: Bioabsorbable interference screw - 1 piece.

A detailed description of the subject of the contract is contained in the model contract constituting Annex 3 to the Terms of Reference and a description of the subject of the contract being Annex 8 to the SWZ. The provisions of the SWZ should be read along with possible changes in the content of the SWZ, which are, for example, the result of answers to the Contractors' inquiries.

Part (package) 2: Knee revision endoprostheses

Part (package) 2: Knee revision endoprostheses, including:

Task 1 Knee inspection endoprosthesis - 5 pieces;

Task 2 Set of modular knee inspection prosthesis - 1 piece (kpl).

A detailed description of the subject of the contract is contained in the model contract being Annex 3 to the SWZ and a description of the subject of the contract being Annex 8 to the SWZ. The provisions of the SWZ should be read along with possible changes in the content of the SWZ, which are, for example, the result of answers to the Contractors' inquiries.

Part (package) 3: Cement-free hip endoprosthesis ceramics/polyethylene

Part (package) 3: Cement-free hip joint endoprosthesis ceramics/polyethylene - 100 pieces.

A detailed description of the subject of the contract is contained in the model contract being Annex 3 to the SWZ and a description of the subject of the contract being Annex 8 to the SWZ. The provisions of the SWZ should be read along with possible changes in the content of the SWZ, which are, for example, the result of answers to the Contractors' inquiries.

Part (package) 4: Custom made pelvic bone post-selection endoprosthesis made of titanium alloy in 3D technique based on CT and MR (Sterile implant) tests

Part (package) 4: Custom made pelvic bone post-selection endoprosthesis made of titanium alloy in 3D technique based on CT and MR (Sterile implant) tests - 2 pieces.

A detailed description of the subject of the contract is contained in the model contract being Annex 3 to the SWZ and a description of the subject of the contract being Annex 8 to the SWZ. The provisions of the SWZ should be read along with possible changes in the content of the SWZ, which are, for example, the result of answers to the Contractors' inquiries.

Part (package) 5: Transpitusal stabilization of the thoracolumbar spine

Part (package) 5: Transvascular stabilization of the thoracolumbar spine - 70 pieces.

A detailed description of the subject of the contract is contained in the model contract being Annex 3 to the SWZ and a description of the subject of the contract being Annex 8 to the SWZ. The provisions of the SWZ should be read along with possible changes in the content of the SWZ, which are, for example, the result of answers to the Contractors' inquiries.

Part (package) 6: PLIF implant system enabling repositioning of spondylolisthesis in the lumbar region along with transpedicular stabilization of the thoracic-lumbar spine

Part (package) 6: PLIF implant system enabling reposition of spondylolisthesis in the lumbar region along with transpedicular stabilization of the thoracic-lumbar spine - 50 pieces (kpl).

A detailed description of the subject of the contract is contained in the model contract being Annex 3 to the SWZ and a description of the subject of the contract being Annex 8 to the SWZ. The provisions of the SWZ should be read along with possible changes in the content of the SWZ, which are, for example, the result of answers to the Contractors' inquiries.

Part (package) 7: TLIF lumbar tenons

Part (package) 7: TLIF lumbar tenons - 40 pieces.

A detailed description of the subject of the contract is contained in the model contract being Annex 3 to the SWZ and a description of the subject of the contract being Annex 8 to the SWZ. The provisions of the specification should be read along with possible changes in the content of the SWZ, which are, for example, the result of answers to the Contractors' inquiries.

Part (package) 8: PLIF lumbar tenons

Part (package) 8: PLIF lumbar tenons - 40 pieces.

A detailed description of the subject of the contract is contained in the model contract being Annex 3 to the SWZ and a description of the subject of the contract being Annex 8 to the SWZ. The provisions of the SWZ should be read along with possible changes in the content of the SWZ, which are, for example, the result of answers to the Contractors' inquiries.

Part (package) 9: Implants for the reconstruction of WKP from hamstrings mm. popliteal, quadriceps tendon and patellar ligaments

Part (package) 9: Implants for the reconstruction of WKP from hamstrings mm. popliteal, quadriceps tendon and patellar ligaments, including:

Task 1. System for reconstruction of the anterior and posterior cruciate ligament based on cork fixation - 10 pieces;

Task 2. System for reconstruction of the anterior cruciate ligament based on cortical fixation - 5 pieces;

Task 3. System for reconstruction of the anterior and posterior cruciate ligament based on cork fixation - 50 pieces;

Task 4. System for reconstruction of the anterior and posterior cruciate ligament based on cork attachment. - 10 pieces;

Task 5. Button for tibial fastening convex in the shape of a titanium hat - 10 pieces;

Task 6. Specialized thread dedicated to tendon hemming in the reconstruction of the anterior and posterior cruciate ligament - 10 pieces;

Task 7. Titanium interference screw fully threaded - 5 pieces;

Task 8. Titanium interference screw with soft thread - 40 pieces;

Task 9. Biocomposite interference screw for reconstruction of the anterior ACL and posterior PCL ligaments - 20 pieces;

Task 10. Drilling wire with a measuring tape - 5 pieces;

Task 11. Tibial drilling wire - 5 pieces;

Exercise 12. Nitynol wire for interference screw - 5 pieces.

A detailed description of the subject of the contract is contained in the model contract being Annex 3 to the SWZ and a description of the subject of the contract being Annex 8 to the SWZ. The provisions of the specification should be read along with possible changes in the content of the SWZ, which are, for example, the result of answers to the Contractors' inquiries.

Download full details as .pdf
The Buyer:
Małopolski Szpital Ortopedyczno-Rehabilitacyjny im. prof. Bogusława Frańczuka
CPV Code(s):
33141750 - Artificial joints
33183100 - Orthopaedic implants
33184100 - Surgical implants