Analysis apparatus

Contract Value:
-
Notice Type:
Contract Notice
Published Date:
21 December 2022
Closing Date:
23 January 2023
Location(s):
NO082 Viken (NO Norway/NORGE)
Description:
ELISA machine

The purpose of the tender contest is to enter into a contract for the purchase of a new ELISA machine. We are in need of a machine that automates pipetting, washing and reading absorbance for 96-well ELISA plates. The machine must be able to analyse several plates at once. It must also be able to process plates that not full (less than 12 rows). The machine must process viscous liquids consisting of buffer with brain homogenate. This can be a challenging material to work with, so we will be manually transferring the brain material to the ELISA plate before the machine takes over for analysis. The analysis consists of three incubations, with the first being dependent on a rotating/shaking motion. The analysis uses two washing solutions, which foam a bit, so the the machine must be able to handle foam. The machine must be able to pipette five different reagents over to the ELISA plates. It must have good traceability for each individual sample/plate so that we can trace the processes in case of error. We would like a user-friendly machine that is intended for use by many users and large samples.

The purpose of the tender contest is to enter into a contract for the purchase of a new ELISA machine. We are in need of a machine that automates pipetting, washing and reading absorbance for 96-well ELISA plates. The machine must be able to analyse several plates at once. It must also be able to process plates that not full (less than 12 rows). The machine must process viscous liquids consisting of buffer with brain homogenate. This can be a challenging material to work with, so we will be manually transferring the brain material to the ELISA plate before the machine takes over for analysis. The analysis consists of three incubations, with the first being dependent on a rotating/shaking motion. The analysis uses two washing solutions, which foam a bit, so the the machine must be able to handle foam. The machine must be able to pipette five different reagents over to the ELISA plates. It must have good traceability for each individual sample/plate so that we can trace the processes in case of error. We would like a user-friendly machine that is intended for use by many users and with large sample sizes.

Full details of the delivery are in the requirements specification.

Download full details as .pdf
The Buyer:
Veterinærinstituttet
CPV Code(s):
33100000 - Medical equipments
33127000 - Immuno-analysis devices
38000000 - Laboratory, optical and precision equipments (excl. glasses)
38430000 - Detection and analysis apparatus
38432000 - Analysis apparatus