The Fraunhofer IFAM-DD plans to procure a testing stand for the operation, testing, and evaluation of electrolyzer cells and electrolyzer stacks. The testing stand should provide a minimum output of 5 kW, with an operating pressure of at least 30 bar. It should be suitable for alkaline media (KOH) for testing alkaline and AEM electrolyzer cells. Various sizes and pressure levels of electrolyzer stacks should be able to be examined flexibly as test subjects.
LOT-0001
Main area.
See specification for main performance (item 1-67)
LOT-0002
Option 1.
Maintenance contract with cost estimation for 24 months after acceptance and subsequent years, indicate scope of services
LOT-0003
Option 2.
additional gas chromatography for the exact determination of gas purity and composition on anode and cathode side. Indicate accuracy and sampling rate. Smaller values will be rated better. (5/100)