ANNUAL ELECTRONIC OPEN TENDER ABOVE THE THRESHOLDS FOR THE SUPPLY OF 'SURGICAL TECHNIQUE' CPV 33160000-9 [KAE 1311] FOR THE NEEDS OF THE GENERAL HOSPITAL OF LARISSA "KOUTLIMBANEIO & TRIADAPHYLLEIO" WITH A TOTAL ESTIMATED COST OF €242,088.40 PLUS VAT / €299,990.03 INCLUDING VAT, WITH THE OPTIONAL RIGHT UP TO 100% OF THE INITIAL QUANTITIES. THE ESTIMATED COST WITH THE RIGHT OF OPTION AMOUNTS TO €484,176.80 PLUS VAT / €599,980.06 INCLUDING VAT, AND WITH THE CRITERION FOR AWARDING THE MOST ECONOMICALLY ADVANTAGEOUS OFFER BASED SOLELY ON PRICE (LOWEST PRICE). SYSTEMIC NUMBER ESIDIS:378609,1
LOT-0001
UROLOGY 10.
Working sheath for ureter access 10-12Ch & 12-14 Ch and lengths 35 & 45CM, for flexible ureteroscope with introducer, radiopaque ring, hydrophilic coating, and stability system allowing conversion of working guide into safety guide for protection and continuous access to the ureter and kidney.
LOT-0002
UROLOGY 11.
Hydrophilic single-lumen ureteral sheath for flexible ureteroscopy with reduced diameter dilator, smooth transition between dilator and outer sheath, hydrophilic coating on all surfaces and the dilator, and ribbed design along the length. With flexible radiopaque tip 10-12FR and 12-14FR and lengths 25-35-45cm. With a locking system for the dilator, which can be safely operated with one hand. To feature a body of reinforced hardness with metal winding, a flexible atraumatic tip with atraumatic transition to the sheath (which should be evidenced by studies), radiopaque ring at the tip and body, and support holes. The outer coating consists of Pebax material with additional radiopaque barium for optimum radiological imaging. To be available in increasing outer diameters: 11/13 Fr, 12/14 Fr and 13/15Fr and in lengths of 28, 36 and 46 cm.
LOT-0003
UROLOGY 12.
Amplatz-type kidney dilators set. Both the dilators and the sheaths should be radiopaque. They should have a dilating and atraumatic tip. They should be made with a special grinding technique throughout the body. The set should include a special PTFE guide catheter 8fr - 80cm for the secure placement of wire and the guidance of dilators with diameters 14-30fr. Dilators 24-30fr and 30cm with PTFE sheaths 17cm, dilators 12-22fr and 30cm, dilators 6-10fr and 22cm, PTFE dilator 10fr - 30cm.
LOT-0008
UROLOGY 17.
Stone removal basket type Stonizer Advanced with zero tip (tipless) made from a single nickel-titanium wire. To have a spherical ergonomic-designed basket type "mini basket", with a light-reflective tip that offers improved endoscopic visibility. It should have an ergonomic and removable 3-ring handle with a special mechanism to prevent basket damage, designed for one-handed use and allowing 360-degree rotation. The packaging should include a special insertion adapter for placement through the endoscope. To be available with a catheter diameter of 1.9ch, length 120cm, with a basket size of 12mm.
LOT-0004
UROLOGY 13.
Multi-use laser fiber (X10) with diameters of 272, 365, 550 μm and a length of 3m. It should have a socket with different color coding based on the diameter of the fiber for easier identification in low-light environments. It should be usable in general surgery, urology, gastroenterology, gynecology, dermatology, vascular surgery, neurosurgery, and ENT. Special terms:
a. The offered optical fibers must be multi-use and compatible with the hospital's existing Quanta machine.
b. The laser is of Holmium:YAG type with maximum power of 35W, maximum pulse energy of 5J, and maximum pulse frequency of 30Hz.
c. The fiber should be identifiable by the laser.
d. The optical fibers should be delivered sterilized and have the ability to be sterilized with steam or hydrogen peroxide-plasma gas.
Request for 2 (two) fibers number 272,
Request for 2 (two) fibers number 365 and
Request for 2 (two) fibers number 550.
Total 6 PCS.
LOT-0005
UROLOGY 14.
Multi-use emission filter (blast shield) for Quanta urological laser litho.
LOT-0006
UROLOGY 15.
Urological device to prevent retrograde flow of liquids and securing urological instruments to the ureteroscope during endourological procedures. It should have secure locking at the instrument, a screw-in receptacle with a Tuohy-Borst valve with a diameter of 9F, and a luer receptacle with a removable cover with a diameter of 7Fr.
LOT-0007
UROLOGY 16.
Ureteral catheters for stone extraction through ureterorenoscopy with a length of 120cm with 3-6 nitinol wires in straight or spiral arrangement of length 12-18mm and opening 8-11mm, and with a non-tip end that ensures patient safety from injuries and the passage of the catheter to the most difficult areas for stone extraction. The diameter of the catheter should be 1.2-2.2Ch. The basket should be able to be disconnected from the base, providing greater convenience in using the forceps for breaking stones and after the procedure, the possibility for reconnection of the basket with its base for removal from the patient. The handle should allow for the release of the basket after moving the sheath backward and not by advancing the catheter forward, so that the basket exits from the sheath. Also, the Lahme-type handle should have a special mechanism (spring mechanism) that secures the stone once captured, automatically without additional manipulation. Finally, a waterproof plastic Tuohy Borst connector should be included in the set.
LOT-0009
UROLOGY 18.
Front designing basket for capturing and extracting ureteral stones, of triangular loop shape. It should have a reinforced end made of polyester for durability. The triangular loop at the front part should operate as a grasper and simultaneously wrap and securely hold the stone like a basket. The loop should consist of 3 joined wires made of NITINOL, for elasticity, strong resistance to twisting, and a memory to revert to its original shape. The loop opening should have a maximum diameter of 8 mm or 11mm. The sheath should be made of flexible polymer for smooth and easy insertion with a diameter of 1.5 Ch/FR. Length 120cm.
LOT-0010
UROLOGY 19.
Biocompatible hydrogel with plant-based material for the removal of residual small stones after flexible lithotripsy in the kidney. The box should include 10 syringes. (1 box = 10 syringes)
LOT-0011
UROLOGY 20.
Nephrostomy dilators should be radiopaque, with luer lock connector, tapered dilating tip, for guide wire up to 0.97mm. They should be in double-sterilized packaging of 10 pieces. They should range from 6 to 20 ch. They should have clearly colored indications of their diameters.
LOT-0012
OPHTHALMOLOGY 1.
Polishing cannula for the posterior chamber. (polisher – silicontip) with a cylindrical tip and silicone coating 7mm and 0.40X22mm angled 45°, 11mm from the tip 25G cylindrical tip 10mm the sleeve.
LOT-0013
OPHTHALMOLOGY 2.
Hydrodissection cannula angled 45°, 0.40x22mm, 11mm from the tip, 25G with cylindrical tip.
LOT-0014
OPHTHALMOLOGY 3.
Pearce-type hydrodissection cannula 25G, angled 35°, 0.50x22mm, 8mm from the tip, with a flat tip.
LOT-0015
OPHTHALMOLOGY 4.
Capsule rupture- capsule cutting needles (cystotomes) 25G, 0.50x16mm.
LOT-0016
OPHTHALMOLOGY 5.
Anterior chamber cannula 27G, angled with a convex tip 45° 6 mm 0.40x22mm. With a flattened tip, designed for secure insertion through incision and manipulation inside the eye, in packaging of 10 pcs.
LOT-0017
OPHTHALMOLOGY 6.
Retro-bulbar anesthesia needles 25G, 0.50x38mm suitable for injecting anesthetics into muscle tissue, packaging of 10 pcs.