The market is broken down into fixed lump sum services and non-package services
Flat-rate firm services:
Mission 1 - radiological measurements in the material zone (cf. § 3.1 of the CSTP)
Mission 2 - maps of the office area (see § 3.2 of the CSTP)
Non-package services
• carrying out radiological measurements by sampling at ceilings,
• carrying out radiological measurements requiring the removal of false ceilings,
• 100% mapping of a surface,
• taking samples by bush hammering,
• the taking of samples by coring,
• radiological analyses,
• chemical analyses
• carrying out measurements by spectrometry,
• the use of shielding,
• the realization of finer radiological measurements,
• samples with asbestos risk,
• carrying out gamma X measurements.
Fixed flat-rate services
o Mission 1: Radiological measurements in the “material zone” (cf. § 3.1 of the CSTP),
o Mission 2: Mapping of the office area (see § 3.2 of the CSTP)
Services outside the package (scenario)
400 smears ceiling, wall or floor (see § 4.1 CSTP),
5 smears on the ceiling in the same room (cf. § 4.1 of the CSTP) for 22 premises therefore a total of 110 smears,
5 additional direct radiological measurements on the ceiling in the same room (see § 4.1) for 3 ceilings therefore a total of 15 measurements,
Radiological measurements with false ceiling removal (cf. § 4.2 of the CSTP) for 5 premises, i.e. a total of 25 measurements,
Mapping on 100% of the surface of a 20 m2 cell (cf. § 4.3 of the CSTP) for 10 surfaces of 20 m2 each, i.e. 200 m2
Assembly/disassembly of site containment: 5
Domestic bush hammering, (see § 4.4 of the CSTP): 6
External bush hammering, (see § 4.4 of the CSTP): 10
Internal coring, (see § 4.5 of the CSTP): 1
External coring, (see § 4.5 of the CSTP): 1
Radiological analysis (spectro alpha) of a sample (see § 4.6 of the CSTP): 1
Chemical analysis (cf. § 4.7 of the CSTP): 10
Gamma scanning measurements on 1 core (cf. § 4.8 of the CSTP): 1
Installation of shielding on the measuring device (cf. § 4.9 of the CSTP: 1
Establishment of biological protection for a room to be measured (cf. § 4.9 of the CSTP): 10
Finer measurements on a mesh (see § 4.10): 60
Arrangement for asbestos hazard for a containment (see § 4.11 of the CSTP): 4
Realization of gamma X mapping for an area of the order of 20 m2 (cf. § 4.12 of the CSTP)
Carrying out a measurement for singularity (cf. § 3.1.4 of the CSTP)