The advertised measure is lot 14 geothermal drilling for the construction project "New construction of the Uncle Eagle Owl Day Care Centre" for about 400 children in Halle.
- 19 holes for geothermal probes, D=152 mm, probe length 130 m
- 19 pcs. double U geothermal probes 32x3.0 mm, probe length 130 m
- 1 Stck. Geothermal Response Test
- 2 pcs. distribution shafts made of PE for 9-10 probe circuits
- approx. 900 lfm piping made of PE 100, 40x3.7 mm, underground
- approx. 60 lfm piping made of PE 100, 63x5.8 mm, underground
- approx. 10 lfm piping made of PE 100, 75x6.8 mm, underground
- 1 piece of documentation, commissioning of geothermal probe system