The building consists mainly of the building materials concrete (sub-areas in exposed concrete quality) and wood (cross-laminated timber) also in partial areas in visible quality. Due to the slope situation, the building has a partial basement. The foundation of the non-basement hall is from the
Basement level from quilted. The basement serves school purposes (lessons, after-school care) and also consists of exposed concrete walls and interior walls in cross-laminated timber construction.
Key data:
Prallwand: ca. 236 m²
Gates/doors: 5 pcs.
Baffle wall system, baffle wall: approx. 236 m², gates/doors: 5 pcs.
All flat cladding elements must be formed in accordance with DIN 18032 Part 3.
Wall cladding made of strip-shaped glued 3-layer cross-laminated timber elements as
acoustically effective cladding with the following specifications:
- Wood type spruce, astrein, simple, smooth sanded and chamfered
- simply impregnated
- Visible surface with 20 mm wide strips
- Joint width 4 mm vertical
- layered version, middle layer made of soft wood fibre 70% absorber content, alpha w = 0.65
- flame retardant B-s2,d0
Attach the substructure concealed. Wall height 2700 mm as a continuous baffle wall element
without shock
,