Description:
Successive deliveries of reagents, calibrators, control and consumable materials for coagulology along with the lease of the analyzer to the Medical Diagnostic Laboratory of the Independent Public for

The subject of the contract is successive delivery to the Medical Diagnostic Laboratory SPZOZ Warszawa Wola-Śródmieście at 54 Elekcyjna Street

in Warsaw, laboratory reagents, calibrators, control and consumable materials for coagulology, along with the lease of the analyzer and the possibility of connecting the analyzer to the Marcel laboratory IT system, training employees in the proper operation of the apparatus. The detailed scope of the contract, quantities are specified in Annex 2A, the minimum required parameters of the analyzer are specified in Annex 2B to the SWZ.

1. Prothrombin time, human recombinant thromboplastin with an ISI of 1.0 (+/ - 0.1) lasted after reconstitution for a minimum of 5 days at 2-8 feet. C and on board the analyzer number of markings 27000

2. Liquid APTT reagent containing synthetic phospholipids as a stability stabilizer after opening the package lasts at least 4 weeks at refrigerator temperature and minimum 5 days on board the analyzer quantity of determinations 9000

3. Fibrinogen classic Clauss method minimum stability after dilution: 3 days at 2-8 feet. C in the original vial, 1 month at -20 ft. C in the original vial, 8 hours on board the analyzer. Number of designations: 3000

4. Freeze-dried normal control plasma with the possibility of freezing (confirmed by the reagent manufacturer) stability after dissolution for a minimum of 24 hours - at a temperature of 15-25 feet. C in original vial for: PT, fibrinogen, APTT

5. Control pathological plasma with the possibility of freezing (confirmed by the manufacturer of reagents) stability after dissolution minimum 24 hours - at a temperature of 15-25 feet. C in original vial for: PT, fibrinogen, APTT

6. Multi-parameter calibrator with the possibility of freezing, calibration not more than once per series of the given reagent Stability after reconstitution: - 24 h at 2-8 feet. C in the original vial for PT, Fibrinogen

7. Consumables, accessories for the analyser and additional reagents necessary to perform the above tests