Complete supply and installation of multi-function ducts with built-ins
for the connection of theatrical technology. The required supply lines are
by an electrical company commissioned by the theatre.
Delivery and assembly of
- 124 m multifunctional channel 180x120mm made of aluminium with lid
and 52 pieces of end plates, color black. Assemble in sections
- 76 m multifunctional channel 110x80mm made of aluminium with lid
and 102 pieces of end plates, color black. Assemble in sections
- 27 gear trays with control flap
- Complete internal wiring of the multifunction channels
with the required lines
- 32 trigger clamps for attachment to trusses
- 64 professional clamps for attachment to L-profiles
- 408 earthed sockets with hinged lid
- Approx. 950 built-in sockets of type XLR, etherCON, opticalCON, HD-SDI
and UHF antennas BNC sockets
- LF and high-voltage supply lines from the offsets to the trusses
- Three floor boxes in the hall with fixtures and fittings
- Delivery and installation of CCE add-on plugs
- Delivery and installation of D-series fixtures for already
Existing AP or flush-mounted cans (approx. 16 pieces)