Water, sewage and fire extinguishing systems
- 180 m SML pipe DN 125 in buildings
- 1,150 m SML pipe DN 100 in buildings
- 1,100 m SML pipe DN 80 in buildings
- 150 m SML pipe DN 50 in buildings
- 3 pcs double lifting system SW 1 faeces free
- 180 m pipeline from non-r. Steel DN 40, 42x1,5mm
- 250 m pipeline from non-r. Steel DN 32, 35x1,5mm
- 350 m pipeline made of non-r. Steel DN 25, 28x1,2mm
- 500 m pipeline made of non-r. Steel DN 20, 22x1,2mm
- 2,500 m pipeline from non-r. Steel DN 15, 18x1,0mm
- 1 PCS DRINKING WATER PRESSURE BOOSTER SYSTEM
- 30 pcs flushing toilet without rinsing rim, wall-hung, length 540
- 30 pcs washbasin width 600 mm, white - 1 pcs light liquid separator system - 1 pcs oil sludge trap - 1 pc extinguishing water tank 5,5m³ made of HDPE
- 1 pc extinguishing water pump - 2 pcs electric extinguishing monitor, type FWM-2-EL, stainless steel 316