New construction of the vocational school centre in Constance - drywall construction work (walls) buildings GT1 and GT2
Drywall work walls separated for the components GT1 and GT2 consisting of
PARTITIONS WITHOUT FIRE SAFETY REQUIREMENTS
PARTITIONS WITH FIRE PROTECTION REQUIREMENTS
FACING SHELLS AND MANHOLE WALLS
wall coverings
blanketwear
Hauptmassen GT1:
without fire protection requirement:
- Partition wall system on on-site steel UK approx. 180 m²
- non-load-bearing interior walls, different thicknesses approx. 475 m²
with fire protection requirement:
- Partition walls F30 approx. 60 m²
- Partition walls F60 approx. 120 m²
Vorsatzschalen:
- free-standing facing shells, different thicknesses approx. 130 m²
- Directly attached facing shell, different thicknesses approx. 95 m²
Paneling:
- Birch, different dimensions approx. 135 m²
- Galvanized sheet steel, different dimensions approx. 160 m²
Blanket clothing:
- OSB Direktbekleidung ca. 115 m²
Hauptmassen GT2:
without fire protection requirement:
- Partition wall system on on-site steel UK approx. 325 m²
- non-load-bearing interior walls, different thicknesses approx. 1120 m²
with fire protection requirement:
- Partition walls F30 approx. 100 m²
- Partition walls F60 approx. 110 m²
Vorsatzschalen:
- free-standing facing shells, different thicknesses approx. 300 m²
- Directly attached facing shell, different thicknesses approx. 280 m²
Paneling:
- Birch, different dimensions approx. 260 m²
- Galvanized sheet steel, different dimensions approx. 120 m²
Blanket clothing:
- OSB Direktbekleidung ca. 135 m²