LOT-0001
Direct-PCR multiplex kit for a set of 18 STR loci (PowerPlex® 18D System - Promega or equivalent).
- allows amplification within a short time (80 min) of unextracted samples such as pre-processed buccal swabs or DNA extracts; amplicons < 450 bp;
- set of 17 STR loci (tetranucleotide repeats, pentanucleotide repeats, and the sex marker Amelogenin;
- amplification for a total reaction volume of 25 µl and a sample volume of 2 µl;
- the kit is compatible with thermocyclers 9700 and genetic analyzers 3130xL and 3500xL calibrated spectral for the PowerPlex® 5C Matrix Standards matrix
- validated for use in judicial genetics and paternity testing;
200 reactions/kit
LOT-0002
Preliminary sample preparation solutions for amplification with direct PCR kits (SwabSolution™ - Promega or equivalent).
- serves for the pre-processing of saliva swabs for direct PCR amplification, without a prior step of DNA extraction from the sample
- reagents in the form of solutions: ●1x100 ml SwabSolution™ Reagent and ● 1x500μl 5X AmpSolution™ Reagent
100 reactions/kit
LOT-0003
Anodic buffer solutions for the 3500XL genetic analyzer (Applied Biosystems or equivalent).
- used for capillary electrophoresis on the 3500XL analyzer
- the buffer solutions are pre-prepared and packaged in plastic cuvettes (specific for anode), each marked with a radio-frequency identification label and sealed with a plastic film
- The kit is delivered in a box containing 4 plastic cuvettes;
kit with 4 cuvettes with buffer solutions
LOT-0004
Cathodic buffer solutions for the 3500XL genetic analyzer (Applied Biosystems or equivalent).
- used for capillary electrophoresis on the 3500XL analyzer
- the buffer solutions are pre-prepared and packaged in plastic cuvettes (specific for cathode), each marked with a radio-frequency identification label and sealed with a plastic film
- The kit is delivered in a box with 4 plastic cuvettes;
kit with 4 cuvettes with buffer solutions
LOT-0005
POP 4 Polymer for capillary electrophoresis on the 3500 XL analyzer (POP4 - Applied Biosystems or equivalent).
- used for fragment analysis protocols and sequencing on the 3500 XL genetic analyzer
- Bottle (plastic bag) for 384 samples (60 runs), stable on the device for 7 days; marked with a radio-frequency identification label
3.5 ml bottle
LOT-0006
Multiplex PCR kit for a set of 16 STR loci (AmpFLSTR® Identifiler™ Plus - Applied Biosystems or equivalent).
- allows amplification in a single reaction of genomic DNA extracted in advance from biological samples; reaction volume 25 µl
- set with 15 tetranucleotide type STR loci (D18S51, D21S11, TH01, D3S1358, FGA, TPOX, D8S1179, vWA, CSF1PO, D16S539, D7S820, D13S317, D5S818, D2S1338, D19S433) and the sex marker Amelogenin,
- amplification enzyme AmpliTaqGold Polymerase
- amplicons with size <360 bp
- primers having the following fluorescent marking = NED™, VIC®, LIZ™, FAM™, PET
- validated for use in judicial genetics and paternity testing optimized for working with degraded samples
200 reactions/kit
LOT-0007
ECL substrate kit for chemiluminescent detection.
- solution used as a substrate for secondary antibodies conjugated with HRP;
- BioRad or equivalent, strictly according to the specifications;
- compatible with digital image detection;
- should provide maximum clarity of captured images;
- should contain Western Peroxide and Western Luminol/Enhancer reagent;
- should ensure reproducibility of results;
- the product is delivered with a quality and compliance certificate issued by the manufacturer, translated into Romanian;
- the product must be presented in the original packaging of the manufacturer, which must specify: name of the manufacturer, product name, quantity and batch, expiration date, storage conditions;
- should display the mention: for in vitro diagnostic use only;
- minimum shelf life of one year from the date of delivery;
packaging: kit with 1 bottle x 100 ml Clarity Western Peroxide reagent and 1 bottle x 100 ml Clarity Western Luminol/Enhancer reagent.
LOT-0008
Western Blot blocking solution.
- solution used for rapid blocking of proteins transferred to membrane (maximum 5 minutes);
- should have high sensitivity for all Western Blot variants, regardless of the immunodetection method (chemiluminescent or fluorescent);
- should ensure reproducibility of results;
- should reduce nonspecific binding of antibodies;
- should be compatible with the use of phospho-specific antibodies;
- the product is delivered with a quality and compliance certificate issued by the manufacturer; translated into Romanian;
LOT-0009
Absolute ethyl alcohol (compatible with Bio-Optica processing equipment).
histological reagent used in tissue processing and common histological staining
-(non-food use) Grading 99.2%Technical specifications according to standard 113 ;
- clear colorless appearance, molecular weight 46.07 g / mol
Packaging: plastic bottle/ 1 liter
We request samples
The requested reagents will be accompanied by technical data sheets and will have a shelf life, at the time of delivery, of 18-24 months.
LOT-0010
Isopropyl Alcohol (compatible with Bio-Optica processing equipment).
- histological reagent necessary for the processing of histopathological tissues
-(non-food use) Molecular weight 60.10 g/mol
- density 20%, residues upon evaporation 0.003%
We request samples
The requested reagents will be accompanied by technical data sheets and will have a shelf life, at the time of delivery, of 18-24 months.
LOT-0011
Xylene (compatible with Bio-Optica processing equipment).
Xylene-Formula: C6H4(CH3)2,Molecular weight: 106.16 g/mol
Warranty 12 months, Content (all isomers C8H10) % min. 99,Distillation range (min. 95% vol.) °C 138-142
Acidity (HCl) % max. 0.004,Residue upon evaporation % max. 0.001,Alkalinity (NaOH) % max. 0.0005,Water % max. 0.02
We request samples
The requested reagents will be accompanied by technical data sheets and will have a shelf life, at the time of delivery, of 18-24 months.
LOT-0012
Acetone (compatible with Bio-Optica processing equipment).
Acetone-„Acidity (acetic acid) % max 0.0012 ,Aldehydes (formaldehyde) % max 0.0005 ,Water % max 0.30
Content/Purity % min 99.92,Density, g/mL 0.789 ,Iron (Fe) % max 0.00001 ,Methanol % max 0.0123 ,Lead (Pb) % max 0.000001 ,Dry residue % max 0.001 ,KMnO4 test % max 0.00025 ,liter x 5
We request samples
The requested reagents will be accompanied by technical data sheets and will have a shelf life, at the time of delivery, of 18-24 months.
LOT-0013
Perls Kit.
Perls kit for 100 tests for the determination of ferric ions in tissue sections.
A) Potassium ferocyanide solution 30 ml
B) Acid activation buffer 30 ml
C) Carmalum according to Mayer 30 ml
Results: determination ferric ions....blue, Nuclei-red.
Storage temperature 15-25 ° C.
Procedure time 35 minutes
Shelf life 2 years
CE marked product.
We request samples
The requested reagents will be accompanied by technical data sheets and will have a shelf life, at the time of delivery, of 18-24 months.
LOT-0014
Masson Trichrome Kit (Bio Optica or equivalent).
Staining for highlighting glycogen
Reagents:
A - Weigert's iron hematoxylin sol A - 18 ml
B - Weigert's iron hematoxylin sol B - 18 ml
C - Alcoholic picric acid solution - 30 ml
D - Ponceau B solution - 30 ml
E - Phosphomolybdic acid solution - 30 ml
F - Masson aniline solution - 30 ml
Preparation time 35 min.
Storage temperature 15-25˚C
Kit 100 tests
We request samples
The requested reagents will be accompanied by technical data sheets and will have a shelf life, at the time of delivery, of 18-24 months.
LOT-0015
XL Autowash AC/AL (ERBA Lachema – XL 200 or equivalent).
Cleaning solution;
Reagent kit packaging:
R1 ( AC ) 5 x 44 ml
R2 ( AL ) 5 X 44 ml;
Stability: 15 - 25ºC until the expiration date;
Shelf life: 12 months from the date of purchase.
LOT-0016
Ammonium 25%.
Chemical reagent for solution analysis 25%
boiling point 37.7 °C (1013 hPa), density0.903 g/cm3 (20 °C) , nonvolatile ≤10 ppm, carbonate≤10ppm, chloride≤0.5ppm, phosphate≤0.5ppm,sulfate≤2ppm,reducing agents≤5ppm
- quality Merck, Sigma or equivalent
-certificate of quality and compliance issued by the manufacturer translated into Romanian;
-products must be presented in the original packaging of the manufacturer, which must specify: name manufacturer, designation, quantity and batch of the product, expiration date, storage conditions, added preservatives;
-delivery of products with a minimum of 18 months before the expiration date,
packaging: bottle /1liter
LOT-0017
Ethyl alcohol standard in human blood conc. 0.2g/l.
- concentration of 0.2 g/l
- packaging max 1.5 ml/vial
- certificate of quality and compliance issued by the manufacturer translated into Romanian
- products must be presented in the original packaging of the manufacturer, which must specify: name manufacturer, designation, quantity and batch of the product,
expiration date, storage conditions, added preservatives,
- delivery of products with a minimum of 18 months before the expiration date;
LOT-0018
Ethyl alcohol standard in human blood conc. 0.80g/l.
- concentration of 0.8 g/l
- packaging max 1.5 ml/vial
- certificate of quality and compliance issued by the manufacturer translated into Romanian
- products must be presented in the original packaging of the manufacturer, which must specify: name manufacturer, designation, quantity and batch of the product,
expiration date, storage conditions, added preservatives,
- delivery of products with a minimum of 18 months before the expiration date;
LOT-0019
Ethyl alcohol standard in human blood conc. 3.00 g/l.
- concentration of 3.00 g/l
- packaging max 1.5 ml/vial
-- certificate of quality and compliance issued by the manufacturer translated into Romanian
- products must be presented in the original packaging of the manufacturer, which must specify: name manufacturer, designation, quantity and batch of the product,
expiration date, storage conditions, added preservatives,
- delivery of products with a minimum of 18 months before the expiration date;
LOT-0020
Rapid immunological test for drugs in urine-12 drugs.
- for urine quantities under 1ml
- individual packaged cassette type tests, with individual pipette
- cut-off limit
- for qualitative determination of 12 drugs (amphetamine-cut off 300ng/ml,
cocaine –cut off 100-150 ng/ml,
cannabinoids – cut off 25-50 ng/ml,
methamphetamines-cut off 300-500 ng/ml,
± opioids- cut-off 2000ng/ml,
phencyclidine- cut off 25ng/ml,
benzodiazepines- cut off 200-300 ng/ml , tricyclic antidepressants-cut off 1000 ng/ml, barbiturates cut off 300ng/ml,
MDMA-cut off 500 ng/ml,
methadone- cut off 300ng/ml,
morphine- cut off 100-300 ng/ml) , ± buprenorphine 10ng/ml
- certificate of quality and compliance issued by the manufacturer translated into Romanian
- products must be presented in the original packaging of the manufacturer, which must specify: name manufacturer, designation, quantity and batch of the product, expiration date, storage conditions;
- delivery of products with a minimum of 18 months before the expiration date;
- packaging individual test a minimum of 20 pcs x 1 box
LOT-0021
Immunological test for drugs in blood Evidence MultiSTAT.
-compatible with Evidence MultiSTAT
- for the detection of drugs in blood
- certificate of quality and compliance issued by the manufacturer translated into Romanian
- products must be presented in the original packaging of the manufacturer, which must specify: name manufacturer, designation, quantity and batch of the product, expiration date, storage conditions;
- delivery of products with a minimum of 18 months before the expiration date;
- packaging: kit for 12 determinations