Purchase contract for the acquisition of products/apparatus with technical content and quantities detailed in the public procurement Technical Description in 12 lots as follows: 1st lot: Laboratory equipment 1. Laboratory refrigerator 2. Laboratory refrigerator freezer 3. Ultrasonic cleaner 4. Magnetic stirrer 5. Vortex mixer 2nd lot: Analytical balance 1. Analytical balance 3rd lot: Gas chromatograph system 1. Gas chromatograph system 4th lot: Radiation protection devices 1. Hazardous waste storage 2. Outfit monitor (hand-foot contamination meter) 3. Surface contamination meter 4. Personal dosimeter with readout 5th lot: Radiological dose measuring instruments 1. Dose calibrator 6th lot: Digital pH meter 1. Digital pH meter 7th lot: LAL tester 1. In vitro endotoxin test (Limulus Amebocyte Lysate) tester 8th lot: Label printer 1. Laboratory label printer 9th lot: Digital timer 1. Digital timer 10th lot: Liquid chromatograph 1. Liquid chromatograph 11th lot: Water purification system 1. Water purifier 12th lot: Gamma spectrometer 1. Gamma spectrometer In all lots, the procurement includes: delivery of the products to the performance site, as well as the handover of user manuals and product documentation. The procurement includes the assembly and installation for the purpose of intended use, and the training of the operating personnel as follows: for the 3rd lot, 3. Gas chromatograph system: The procurement includes assembly and installation for intended use and training of 3 personnel for a total of 10 hours. For the gas chromatograph system, the procurement also includes conducting qualification of the assembled and installed system, handing over the system IQ/OQ documentation, and providing online or telephone application support/advice. For the 5th lot, 5. Dose calibrator: The procurement includes assembly and installation for intended use and training of 3 personnel for a total of 2 hours. For the 7th lot, 7. In vitro endotoxin test (Limulus Amebocyte Lysate) tester: The procurement includes assembly and installation for intended use and training of 3 personnel for a total of 5 hours. For the 10th lot, 10. Liquid chromatograph: The procurement includes assembly and installation for intended use and training of 3 personnel for a total of 10 hours. The procurement includes, for the liquid chromatograph system, conducting qualification of the assembled and installed system, as well as the handover of the system IQ/OQ documentation, and providing online or telephone application support/advice. For the 12th lot, 12. Gamma spectrometer: The procurement includes assembly and installation for intended use and training of 3 personnel for a total of 2 hours, as well as online or telephone application support/advice. The detailed technical content of the instruments/products is included in the Technical Description section of the public procurement document (Public Procurement Document IX), as well as the separate attached technical description-professional offer table. For all lots, the offered products must be new; the submission of used products will not be accepted by the Contracting Authority! For all lots: References to a specific manufacturer, specific type as specified in the technical description, where applicable – according to paragraph 46 (3) of Decree 321/2015 (X. 30.) – were made for the clear specification of the nature of the object/the relevant technical parameters. In these cases, the Contracting Authority will accept as suitable the object/technical parameter that meets the detailed specified values regarding the object/the relevant technical parameters, that is considered ‘equivalent’ based on the given criteria. In cases where the technical content was determined according to paragraph 46 (2) of Decree 321/2015 (X. 30.), the Contracting Authority examines whether the offered technical parameters meet the performance and functional requirements set against the prescribed parameters.


LOT-0002
EKR000620062026/2
Analytical balance.
2nd lot: Analytical balance 1. Analytical balance - 1 pcs Technical requirements for the product: "Measurement range: between 0-300 (+/- 10%) g • Sensitivity [d]: 0.1 mg • Pan size: min 80 mm • Draft protection: Yes • Tare capacity: across the full measurement range" Power supply [V]: 230 V~ (± 10 %), 50/60 Hz EU standard power connector. The references to a specific manufacturer, specific type as specified in the technical description, where applicable – according to paragraph 46 (3) of Decree 321/2015 (X. 30.) – were made for the clear specification of the nature of the object/the relevant technical parameters. In these cases, the Contracting Authority will accept as suitable the object/technical parameter that meets the detailed specified values regarding the object/the relevant technical parameters, that is considered ‘equivalent’ based on the given criteria. In cases where the technical content was determined according to paragraph 46 (2) of Decree 321/2015 (X. 30.), the Contracting Authority examines whether the offered technical parameters meet the performance and functional requirements set against the prescribed parameters. The procurement includes the delivery of the product to the performance location, as well as the handover of user manuals, product documentation. The offered product must be new; the submission of used products will not be accepted by the Contracting Authority!


LOT-0003
EKR000620062026/3
Gas chromatograph system.
3rd lot: Gas chromatograph system 1. Gas chromatograph system – 2 pcs Technical requirements for the product: "Gas chromatograph (2 pcs) The temperature, pressure/flow, carrier gas, detector gas, parameters must be displayed on the gas chromatograph graphic display. The device must be capable of operating with H2 and N2 gases in addition to He carrier gas. Flow rate range: adjustable between at least 0-1250 ml/min for He gas. It should provide for the application of constant linear flow rate, constant pressure, and constant column flow mode. The column space must be heatable up to min. 300 °C. The temperature in the column space should be adjustable with an accuracy of 0.1 °C. The number of temperature program steps must be at least 20. The number of pressure program steps must be at least 7. Cooling rate: max. 4 minutes from 450 °C to 50 °C. The maximum settable pressure for the injector must be at least 680 kPa. The maximum settable temperature for the injector must be at least 425 °C. There should be a possibility for tool-free installation of the column. The device should have space for at least 3 detectors and 2 injectors for future expandability. The delivered system must be suitable for identifying and quantifying the residual solvents used in [18]F-FDG synthesis – specifically acetone, ethanol, and acetonitrile after assembly, commissioning, and validation." "Injector (2 pcs) Split/Splitless injector (SPL): Suitable for connecting capillary columns of all sizes: 50-530 µm ID. Must include a built-in gas-saving function. Its application does not affect measurement efficiency. It must have electronic septum purge to avoid cross-contamination. The injector port must be openable and closable without tools. Syringe 10F-S-0.63 10 µl 10 pcs. Graphite Ferrule 0.5 50 pcs. Premium Green Septa 15 pcs. Deactivated Liner insert, wool fleece Split 15 pcs. Deactivated Liner insert, wool fleece Splitless 10 pcs. O-Ring sealing ring 100 pcs. Threaded ampoule 2ml, 12x32mm, 10-425, 100 pcs 10-425 plastic screw cap silicone/PTFE." "Detector (2 pcs) Flame ionization detector (FID): Minimum detectable quantity: <3 pg C/s. The configurable maximum temperature must be at least 425 °C. The detector dynamic range must be at least 107. The electronic pressure control must be capable of regulating three gas flows: air: 0-800 mL/min, H2: 0-100 mL/min, makeup gas (N2 or air): 0-100 mL/min. Flame sensing and automatic ignition." "Automatic sample injector (2 pcs) Suitable for sample injection into various types of injectors, Minimum number of sample sites: 30 pcs (1.5 mL vials). Number of wash sites: 4 pcs (4 ml). The placement of the sample injector must allow manual injection without assembly. Built-in parameters for traditional, solvent wash (with or without a second solvent), and large volume injection. Capable of the so-called “sandwich” technique. Applicable volumetric liquid syringes: 0.5, 5, 10, 50 and 250 µL. Changeable absorption and needle penetration speeds. Peak area repeatability: <0.3 % RSD Cross-contamination: <7 ppm Supported syringe sizes: 0.5 µL, 5 µL, 10 µL, 50 µL, 250 µL Must have self-diagnostic function. Supports the incorporation of a heating/cooling module. Viscosity delay adjustable from at least 0 - 99.9 s. Must have vial sensor. There must be an option for overlapping analysis. Includes 200 pcs of 1.5 ml vials with cap and septum." "Control software (1 pcs) with installation Suitable for the full control of the device. Warns or gives error messages when the device is not functioning properly. Counts the injections. If the number of injections exceeds the value specified by the user on the septum and/or the liner, it sends a warning message for replacement. The software includes an audit trail function. The software includes method and sample series wizard functionality. The device can be started and stopped automatically at a pre-specified time." "Control computer (1 pcs) Op. system: min. MS Windows 11 PRO Processor: min. CORE I5 2.4-2.8 GHz Memory: min. 16 GB min. 1000MHz DDR4 Storage: min. 512 GB SSD + 512 GB HDD Keyboard: English layout (QWERTY) Mouse: Optical Monitor: Display size: 15.6-26", Resolution (max.): 1920X1080, Color bit: 8-bit The control software offered in this section must be installed." Power supply [V]: 230 V~ (± 10 %), 50/60 Hz EU standard power connector. The references to a specific manufacturer, specific type as specified in the technical description, where applicable – according to paragraph 46 (3) of Decree 321/2015 (X. 30.) – were made for the clear specification of the nature of the object/the relevant technical parameters. In these cases, the Contracting Authority will accept as suitable the object/technical parameter that meets the detailed specified values regarding the object/the relevant technical parameters, that is considered ‘equivalent’ based on the given criteria. In cases where the technical content was determined according to paragraph 46 (2) of Decree 321/2015 (X. 30.), the Contracting Authority examines whether the offered technical parameters meet the performance and functional requirements set against the prescribed parameters. The procurement includes: delivery of the products to the performance location, as well as the handover of user manuals and product documentation, and the assembly and installation for intended use, and training of 3 personnel for a total of 10 hours. For the gas chromatograph system, the procurement additionally includes the completion of qualification of the assembled and installed system, handover of the system IQ/OQ documentation, and providing online or telephone application support/advice. The offered products must be new; submission of used products will not be accepted by the Contracting Authority!


LOT-0005
EKR000620062026/5
Radiation dose measurement instrument.
5th lot: Radiation dose measuring instruments 1. Dose calibrator - 1 pcs Technical requirements for the product: "Dose calibrator Ionization chamber suitable for measuring 740 GBq F-18 Minimum shielding 3.2 mm lead or equivalent Automatic geometry and linearity test min. 8” touchscreen" "Control software, label printer" Power supply [V]: 230 V~ (± 10 %), 50/60 Hz EU standard power connector. The references to a specific manufacturer, specific type as specified in the technical description, where applicable – according to paragraph 46 (3) of Decree 321/2015 (X. 30.) – were made for the clear specification of the nature of the object/the relevant technical parameters. In these cases, the Contracting Authority will accept as suitable the object/technical parameter that meets the detailed specified values regarding the object/the relevant technical parameters, that is considered ‘equivalent’ based on the given criteria. In cases where the technical content was determined according to paragraph 46 (2) of Decree 321/2015 (X. 30.), the Contracting Authority examines whether the offered technical parameters meet the performance and functional requirements set against the prescribed parameters. The procurement includes: delivery of the products to the performance location, as well as the handover of user manuals, product documentation, and assembly and installation for intended use, and training of 3 personnel for a total of 2 hours. The offered product must be new; submission of used products will not be accepted by the Contracting Authority!


LOT-0001
EKR000620062026/1
Laboratory equipment.

1. Subcontracting scope: Laboratory devices 1. Laboratory refrigerator - 1 piece Technical requirements for the product: "GMP compatible laboratory refrigerator Temperature range: at least +3-16 C, min. 300 liters usable volume [+/- 15%]" Energy consumption: max. 1.05 kWh/24h Alarm: with sound and light signals, Low/high temperature and door open Material of drawers: metal: aluminum or stainless steel Network voltage [V]: 230 V~ (± 10 %), 50/60 Hz EU standard network connector 2. Laboratory freezer refrigerator - 1 piece "Temperature range: adjustable between -25 °C and -10 °C min. 90 liters usable volume GMP compatible" "Energy consumption: maximum 2.06 kWh/24h Network voltage [V]: 230 V~ (± 10 %), 50/60 Hz Alarm: with sound and light signals, in case of low/high temperature and door open" Material of drawers: metal: aluminum or stainless steel Network voltage [V]: 230 V~ (± 10 %), 50/60 Hz EU standard network connector 3. Ultrasonic cleaner - 1 piece "Volume [l]: minimum between 4 liters and maximum 10 liters Tub material: stainless steel Tub thickness min.[mm]: 0.8 Ultrasonic peak power [W] min.: 150W Timer setting [min]: 1 - 15 minutes continuous Temperature setting (C): at least 25-69 degrees Heating power [W]: min. 200W" Network voltage [V]: 230 V~ (± 10 %), 50/60 Hz EU standard network connector 4. Magnetic stirrer - 1 piece "Minimum volume: 1 liter, Variable speed: 100 rpm-1000 rpm or 200rpm-1600 rpm, Power: max 10 w" Network voltage [V]: 230 V~ (± 10 %), 50/60 Hz EU standard network connector 5. Vortex mixer - 1 piece "Hand-operated vortex mixer, up to 1 small test tube can be placed at once, with a maximum diameter of 30 mm" Network voltage [V]: 230 V~ (± 10 %), 50/60 Hz EU standard network connector References to specific brands or types in the technical description – as per Article 46 § (3) of Government Decree 321/2015 (X. 30.) – are made to clearly define the nature of the subject/the relevant technical parameters. In these cases, the contracting authority accepts as acceptable any goods/technical parameters that are equivalent to the detailed values specified regarding the subject/the relevant technical parameter according to the provided criteria. In cases where the technical content has been defined according to Article 46 § (2) of Government Decree 321/2015 (X. 30.), the contracting authority will examine whether the offered technical parameters meet the performance or functional requirements imposed by the prescribed parameters. The procurement includes: delivery of the products to the place of fulfillment, as well as the handover of user manuals and product documentation. The offered products must be new; the contracting authority does not accept offers for used products!


LOT-0004
EKR000620062026/4
Radioprotection devices.
4. Subcontracting scope: Radioprotection devices 1. Hazardous waste storage - 3 pieces Technical requirements for the product: "- Radiation-protected waste storage - Operation: foot pedal - Material: Stainless steel - Radiation protection: 6 mm lead or equivalent - Volume: min. 45 liters max. 60 liters" 2. Clothing monitor (hand-foot contamination meter) - 1 piece Technical requirements for the product: "Hand and foot monitor Stainless steel surfaces Plastic scintillator detector technology" Suitable for measuring beta and gamma radiation Network voltage [V]: 230 V~ (± 10 %), 50/60 Hz EU standard network connector 3. Surface contamination meter - 2 pieces Technical requirements for the product: "Min. 170 cm² sensing area Calibration factor min. 50 radionuclides Suitable for α- β-γ detection, Geiger-Müller tube detector Adjustable warning level, with sound signal Dose sensitivity: 0.1 μSv/h - 20 mSv/h Energy range: 50 keV to 1.3 MeV" Rechargeable from network voltage [V]: 230 V~ (± 10 %), 50/60 Hz, or battery-operated EU standard network connector 4. Personal dosimeter with reader - 6 pieces Technical requirements for the product: "Personal dosimeter (6 pieces) + USB reader + reading user software Sensitivity min. 30 keV Complies with IP 67 standard Measurement range: 10 µR/h-99 R/h, Energy range: min 40 keV - 1.3 MeV" Personal dosimeter with battery or rechargeable operation Power supply via USB connection. References to specific brands or types in the technical description – as per Article 46 § (3) of Government Decree 321/2015 (X. 30.) – are made to clearly define the nature of the subject/the relevant technical parameters. In these cases, the contracting authority accepts as acceptable any goods/technical parameters that are equivalent to the detailed values specified regarding the subject/the relevant technical parameter according to the provided criteria. In cases where the technical content has been defined according to Article 46 § (2) of Government Decree 321/2015 (X. 30.), the contracting authority will examine whether the offered technical parameters meet the performance or functional requirements imposed by the prescribed parameters. The procurement includes: delivery of the products to the place of fulfillment, as well as the handover of user manuals and product documentation. The offered products must be new; the contracting authority does not accept offers for used products!


LOT-0006
EKR000620062026/6
Digital pH meter.
6. Subcontracting scope: Digital pH meter 1. Digital pH meter - 1 piece Technical requirements for the product: "Measurement range: -1999 - +20000 mV, Resolution: min. 0.1 pH pH measurement range: 1.00-14.00 pH pH accuracy: ±0.01, Temperature range: at least 0 - 100 °C, resolution: min. 0.1 °C" Network voltage [V]: 230 V~ (± 10 %), 50/60 Hz EU standard network connector References to specific brands or types in the technical description – as per Article 46 § (3) of Government Decree 321/2015 (X. 30.) – are made to clearly define the nature of the subject/the relevant technical parameters. In these cases, the contracting authority accepts as acceptable any goods/technical parameters that are equivalent to the detailed values specified regarding the subject/the relevant technical parameter according to the provided criteria. In cases where the technical content has been defined according to Article 46 § (2) of Government Decree 321/2015 (X. 30.), the contracting authority will examine whether the offered technical parameters meet the performance or functional requirements imposed by the prescribed parameters. The procurement includes: delivery of the product to the place of fulfillment, as well as the handover of user manuals and product documentation. The offered product must be new; the contracting authority does not accept offers for used products!


LOT-0007
EKR000620062026/7
LAL tester.
7. Subcontracting scope: LAL tester 1. In vitro endotoxin test (Limulus Amebocyte Lysate) tester - 1 piece Technical requirements for the product: "Quick endotoxin test Recombinant cascade reagent (rCR) Detection range: 0.005-10EU/ml Barcode identification Real-time data analysis Storage capacity: min 8GB" GMP (Good Manufacturing Practices) compatible The device can be integrated into the LIMS system Network voltage [V]: 230 V~ (± 10 %), 50/60 Hz EU standard network connector References to specific brands or types in the technical description – as per Article 46 § (3) of Government Decree 321/2015 (X. 30.) – are made to clearly define the nature of the subject/the relevant technical parameters. In these cases, the contracting authority accepts as acceptable any goods/technical parameters that are equivalent to the detailed values specified regarding the subject/the relevant technical parameter according to the provided criteria. In cases where the technical content has been defined according to Article 46 § (2) of Government Decree 321/2015 (X. 30.), the contracting authority will examine whether the offered technical parameters meet the performance or functional requirements imposed by the prescribed parameters. The procurement includes: delivery of the product to the place of fulfillment, the handover of user manuals and product documentation, as well as assembly and commissioning in a way suitable for intended use and training of 3 personnel for a total of 5 hours. The offered product must be new; the contracting authority does not accept offers for used products!


LOT-0008
EKR000620062026/8
Laboratory label printer.
8. Subcontracting scope: Label printer 1. Laboratory label printer - 1 piece Technical requirements for the product: "Label printing: Monochrome Label size optional width: 12.7-25.4-50.8-76.2-101.6 mm height: 25.58-50.8-76.2-101.6-152.4 mm Printing technology: Thermal transfer Capacity: 3000 labels/day Communication ports: USB, USB 2.0, Wi-Fi Internal memory at least: 512 MB RAM Text size: 4-250 pt" "Adhesive label with strong adhesion, also sticks to hard-to-stick surfaces (e.g., textured, rough, powder-coated surfaces or low surface energy plastics). Aggressive Adhesive Multi-Purpose Polyester Labels for B33 Printers - 1" x 2" "or equivalent" Size: 25.4x50.8 mm x 1500 pieces 3 rolls (= 3 pieces of plastic frame rolled with 1500 print-ready labels)" Network voltage [V]: 230 V~ (± 10 %), 50/60 Hz EU standard network connector References to specific brands or types in the technical description – as per Article 46 § (3) of Government Decree 321/2015 (X. 30.) – are made to clearly define the nature of the subject/the relevant technical parameters. In these cases, the contracting authority accepts as acceptable any goods/technical parameters that are equivalent to the detailed values specified regarding the subject/the relevant technical parameter according to the provided criteria. In cases where the technical content has been defined according to Article 46 § (2) of Government Decree 321/2015 (X. 30.), the contracting authority will examine whether the offered technical parameters meet the performance or functional requirements imposed by the prescribed parameters. The procurement includes: delivery of the product to the place of fulfillment, as well as the handover of user manuals and product documentation. The offered product must be new; the contracting authority does not accept offers for used products!


LOT-0009
EKR000620062026/9
Digital timer clock.
9. Subcontracting scope: Digital timer clock 1. Digital timer clock - 1 piece Technical requirements for the product: Suitable for use in laboratory conditions "4-channel digital stopwatch Timer: 1/10 second or 1/100 minute Adjustment options: Start/ Stop/ Reset Two-way counting: countdown and stopwatch function An audible alert when the set time expires" Memory function Accuracy: min. 0.1 seconds Battery operation, minimum 8 hours of operation The references to specific brands or types in the technical description – as per Article 46 § (3) of Government Decree 321/2015 (X. 30.) – are made to clearly define the nature of the subject/the relevant technical parameters. In these cases, the contracting authority accepts as acceptable any goods/technical parameters that are equivalent to the detailed values specified regarding the subject/the relevant technical parameter according to the provided criteria. In cases where the technical content has been defined according to Article 46 § (2) of Government Decree 321/2015 (X. 30.), the contracting authority will examine whether the offered technical parameters meet the performance or functional requirements imposed by the prescribed parameters. The procurement includes: delivery of the product to the place of fulfillment, as well as the handover of user manuals and product documentation. The offered product must be new; the contracting authority does not accept offers for used products!


LOT-0010
EKR000620062026/10
Liquid chromatograph.
10. Sub-contracting area: Liquid Chromatograph 1. Liquid Chromatograph - 1 pcs Technical requirements for the product: "Liquid Chromatograph 1 pcs High-Performance Liquid Chromatograph (HPLC), gas removal unit, low-pressure gradient generator unit capable of mixing at least four solvents, mixer, automatic sample injector, column thermostat, radio flow detector, RI detector, control software, and computer with printer. The delivered system should be suitable for the [18]F-FDG critical quality control (QC) procedure following assembly, commissioning, and validation, assessing radiochemical purity, chemical identity, and potential contaminants such as chlorodeoxyglucose (ClDG)." "System Control Unit 1 pcs Controls the other modules of the HPLC and maintains communication with the PC. Communicates with the PC via Ethernet. Number of connectable units: min. 4 pcs" "Solvent Delivery Unit 1 pcs Parallel, dual-piston pump or isocratic pump. Maximum pressure: at least 300 bar. Flow rate adjustable between 0.0001-5.0000 mL/min. Flow rate accuracy ≤±2% or ±2µL/min (whichever is better). Flow rate precision ≤0.06%RSD or 0.02 min SD (whichever is better). Gradient mixing concentration adjustable between 0-100% in 0.1% increments. Gradient concentration accuracy ±1%. Operating pH range 1-14. The automatic pump head should have rinsing capability. PEEK analytical mixer, variable volume between 0.4-1.6 ml. Minimum 5-channel de-gassing unit to connect to the system." "Automatic Sample Injector 1 pcs Maximum operating pressure 200 bar (130 MPa). The sample area must be temperature-controlled between 4 °C and 40 °C. Injection volume variable: 0.1-50 µL. The injection volume may optionally be extended to 250 µL. Injection volume reproducibility: RSD <0.3% (for 10µL injection). Applicable pH range: 1-14. Cross-contamination maximum 0.005%. Sample capacity at least: 105 pcs of 1.5 ml vials. Light-protected sample area." "Column Thermostat 1 pcs Air-circulating column thermostat. Temperature range: room temperature 4 °C – 85 °C. Temperature accuracy: ± 0.5 ̊ C. Temperature precision: ± 0.05 ˚C" "Refractive Index Detector 1 pcs Measurement range: 1 - 1.75 RIU Noise: =< 2.5 nRIU Drift: =< 0.1 uRIU/h Range: 0.01 - 500 uRIU Response: with no filtering, 0.05 - 10 s, 10 steps. Must have a polarity switching switch. Zero correction: auto zero, auto optical zero, baseline shift function. Maximum flow rate: between 5-20 ml/min. Thermostated cell. Cell temperature: 5-55 °C. Maximum cell volume: 9 ul." "Radio-Flow Detector 1 pcs Automatic energy calibration. Must have 2 simultaneous counting channels. Should offer spectrum scanning. Energy range: 30 – 2000 keV. Count rate range: 0 – 2,500,000 cps. Dynamic range:0-1.000000 c/s. Linearity: 0 – 600,000 cps r2 >= 0.99. Detector energy range: 60-600 keV. Lead shielding around the detector: min 5 cm. Detector voltage range: 500 - 1200 V (0.5 V setting accuracy). Flow cell volume max. 400µl." "Control Software 1 pcs Database-based software. Controls all modules of the HPLC device and collects data. Start-up function: At a user-specified time, the HPLC device can automatically start, purge each eluent line, equilibrate columns, and start measurements without user intervention. Compliance with 21 CFR Part 11. Must have an audit trail function. User reports customizable" "Operating system: min. MS Windows 11 PRO. Processor: min. CORE I5 2.4-2.8 GHz. Memory: min. 16 GB min. 1000MHz DDR4. Storage: min. 512 GB SSD + 512 GB HDD. Keyboard: English layout (QWERTY). Mouse: Optical. Monitor: Display size: 15.6-26", Resolution (max.): 1920X1080, Color bit: 8 bit. Installation of the control software proposed in this section." "Along with the device, connectors and cables necessary for the operation of the instrument must be delivered, 2 pcs of 250 ml glass bottles for solvents, ARION® NH2 HPLC, 3.0 µm 150 mm × 4.6 mm column or equivalent ARION® SAX HPLC column, 5.0 μm 150 mm × 3.0 mm column or equivalent, 200 pcs of 1.5 ml vials with septum and caps. References to specific brands or types mentioned in the technical description are made to clearly define the nature of the subject/technical parameters in accordance with §46 (3) of the decree 321/2015. In such cases, the contracting authority accepts only equivalent goods/technical parameters that comply with the specified detailed values. Where the technical content is defined in accordance with §46 (2) of the decree 321/2015, the contracting authority examines whether the proposed technical parameters meet the prescribed performance and functional requirements. The procurement includes the delivery of the product to the place of performance, as well as the handover of user manuals and product documentation. The procurement includes the assembly and commissioning in a manner suitable for intended use and training for 3 personnel for a total of 10 hours. Furthermore, concerning the liquid chromatograph system, the procurement also includes the qualification of the assembled and commissioned system, as well as the handover of the system IQ/OQ documentation, and online or phone application support/advice. The proposed product must be new; the contracting authority does not accept offers for used products!


LOT-0011
EKR000620062026/11
Water purification device.
11. Sub-contracting area: Water purification device 1. Water purifier - 1 pcs Technical requirements for the product: "Type I and Type II water. Meets ASTM Type 1, CAP, and ISO 3696 Type 1 water purity standards. Min. 2L/hr ultra-pure water (Type 1) from tap water or pre-purified water storage tank. Min. 5L/hr pure water (Type 2) from tap water. Conductivity 0.055 µS/cm (18.2 MΩ × cm) [+/- 5%]" 20 liter volume tank. Water take-off arm. Wall-mounted design. Suitable for analytical purposes. The system must include a TOC monitor and UV light source. Power supply [V]: 230 V~ (± 10 %), 50/60 Hz EU standard power connector. References to specific brands or types mentioned in the technical description are made to clearly define the nature of the subject/technical parameters in accordance with §46 (3) of the decree 321/2015. In such cases, the contracting authority accepts only equivalent goods/technical parameters that comply with the specified detailed values. Where the technical content is defined in accordance with §46 (2) of the decree 321/2015, the contracting authority examines whether the proposed technical parameters meet the prescribed performance and functional requirements. The procurement includes the delivery of the product to the place of performance, as well as the handover of user manuals and product documentation. The proposed product must be new; the contracting authority does not accept offers for used products!


LOT-0012
EKR000620062026/12
Gamma spectrometer.
12. Sub-contracting area: Gamma spectrometer 1. Gamma spectrometer – 1 pcs Technical requirements for the product: Gamma spectrometer with multi-channel analyzer coaxial HPGe detector Rel. Eff. => 10% @1332keV Detector energy: min. 20 keV – 3 MeV with standard liquid nitrogen (LN2) cooling, 16,000 channel spectral memory, multi-channel analyzer (MCA) analytical software meets GMP requirements. Lead shielding: Min. 100 mm "or equivalent", 30 l Dewar vessel for liquid nitrogen, liquid nitrogen transfer tool min 5 liters. For the real-time identification of isotopes used in nuclear medicine: minimum 99mTc, 18F, 59Fe, 64Cu, 68Ga, 131I, 123I, 124I, 137Cs, 177Lu, 225Ac, 188Re. Local installation, IQ, OQ. References to specific brands or types mentioned in the technical description are made to clearly define the nature of the subject/technical parameters in accordance with §46 (3) of the decree 321/2015. In such cases, the contracting authority accepts only equivalent goods/technical parameters that comply with the specified detailed values. Where the technical content is defined in accordance with §46 (2) of the decree 321/2015, the contracting authority examines whether the proposed technical parameters meet the prescribed performance and functional requirements. The procurement includes the delivery of the product to the place of performance, as well as the handover of user manuals and product documentation, as well as assembly and commissioning in a manner suitable for intended use, and training for 3 personnel for a total of 2 hours, and online or phone application support/advice. The proposed product must be new; the contracting authority does not accept offers for used products!

The Buyer:
Szegedi Tudományegyetem
Additional information:
Link:
Download Full Notice as PDF
Link:
View Full Notice
Link:
Additional document: DOC-01
CPV Code(s):
18523000 - Stopwatches
30173000 - Label applying machines
38000000 - Laboratory, optical and precision equipments (excl. glasses)
38311100 - Electronic analytical balances
38341200 - Radiation dosimeters
38416000 - PH meters
38432200 - Chromatographs
38432210 - Gas chromatographs
38436400 - Magnetic shakers
38436500 - Mechanical stirrers
39711100 - Refrigerators and freezers
42912330 - Water-purifying apparatus
42943200 - Ultrasonic baths
90521100 - Collection of radioactive waste